EFFECTS OF INJECTION SCHEMES AND COLUMN GEOMETRY ON THE PERFORMANCE OF MICROCHIP ELECTROPHORESIS DEVICES

被引:696
|
作者
JACOBSON, SC
HERGENRODER, R
KOUTNY, LB
WARMACK, RJ
RAMSEY, JM
机构
[1] OAK RIDGE NATL LAB,DIV CHEM & ANALYT SCI,OAK RIDGE,TN 37831
[2] OAK RIDGE NATL LAB,DIV HLTH SCI RES,OAK RIDGE,TN 37831
关键词
D O I
10.1021/ac00079a028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glass microchip column was fabricated for free-solution electrophoresis. The channels were wet chemically etched on a substrate using standard photolithographic techniques and were sealed using a direct bonding technique. Two methods of sample introduction are evaluated employing a cross-type channel geometry. With the preferred sample loading method, the volume of the sample plug can be accurately controlled and is time independent, enabling a constant volume to be injected. The injection can be controlled electronically and does not induce any electrophoretic mobility based bias. Separations were performed on a compact chip with a serpentine column geometry that has a 165-mm separation channel in an area of less than 10 mm x 10 mm. Band-broadening effects in a serpentine column pattern were studied.
引用
收藏
页码:1107 / 1113
页数:7
相关论文
共 50 条
  • [41] Simulation and experimental research of the cross-shape-effects on the performance of ion measurement by microchip electrophoresis
    Yang, Mingpeng
    Huang, He
    Cheng, Weiqing
    Liu, Hao
    You, Hui
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (12)
  • [42] Thiol-ene microfluidic devices for microchip electrophoresis: Effects of curing conditions and monomer composition on surface properties
    Tahka, Sari M.
    Bonabi, Ashkan
    Nordberg, Maria-Elisa
    Kanerva, Meeri
    Jokinen, Ville P.
    Sikanen, Tiina M.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1426 : 233 - 240
  • [43] USE OF PELTIER THERMOELECTRIC DEVICES TO CONTROL COLUMN TEMPERATURE IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS
    NELSON, RJ
    PAULUS, A
    COHEN, AS
    GUTTMAN, A
    KARGER, BL
    JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 111 - 127
  • [44] High-performance DNA separations in microchip electrophoresis systems
    Bousse, L
    Dubrow, B
    Ulfelder, K
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 271 - 275
  • [45] Fabrication of microfluidic devices using dry film photoresist for microchip capillary electrophoresis
    Tsai, YC
    Jen, HP
    Lin, KW
    Hsieh, YZ
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1111 (02) : 267 - 271
  • [46] Integrating amperometric detection with electrophoresis microchip devices for biochemical assays: Recent developments
    Ghanim, M. H.
    Abdullah, M. Z.
    TALANTA, 2011, 85 (01) : 28 - 34
  • [47] Sensitivity enhancing injection from a sample reservoir and channel interface in microchip electrophoresis
    Wuethrich, Alain
    Quirino, Joselito P.
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (04) : 927 - 932
  • [48] Single potential electrophoresis microchip with reduced bias using pressure pulse injection
    Lacharme, Frederic
    Gijs, Martin A. M.
    ELECTROPHORESIS, 2006, 27 (14) : 2924 - 2932
  • [49] Microchip electrophoresis with hydrodynamic injection and waste-removing function for quantitative analysis
    Lin, CC
    Chen, CC
    Lin, CE
    Chen, SH
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) : 69 - 74
  • [50] Study of a novel sample injection method (floating electrokinetic supercharging) for high-performance microchip electrophoresis of DNA fragments
    Hirokawa, Takeshi
    Takayama, Yoichi
    Arai, Akihiro
    Xu, Zhongqi
    ELECTROPHORESIS, 2008, 29 (09) : 1829 - 1835