INSTRUMENTAL BROADENING CORRECTION IN SIZE EXCLUSION CHROMATOGRAPHY - COMPARISON OF SEVERAL DECONVOLUTION TECHNIQUES

被引:16
|
作者
GUGLIOTTA, LM
VEGA, JR
MEIRA, GR
机构
[1] CONSEJO NACL INVEST CIENT & TECN,INST DESARROLLO TECNOL IND,CC 91,RA-3000 SANTA FE,ARGENTINA
[2] UNIV NACL LITORAL,RA-3000 SANTA FE,ARGENTINA
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1990年 / 13卷 / 09期
关键词
D O I
10.1080/01483919008048986
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several deconvolution techniques (1–7) and a novel method herein presented, are compared in relation to their ability for correcting size exclusion chromatograms for the undesirable effect of instrumental broadening. Such methods are evaluated on the same computer, and through a ’’synthetic” example of known solution. Methods based on the frequency domain are only applicable to uniform deconvolution problems with stationary statistics. However, in the herein presented heuristic method (based on the Wiener filter in the frequency domain), it is possible to relax this last restriction, and generate solutions that are equivalent to considering signals with time-varying statistics. The evaluated techniques are compared on the basis of quality of results, computational considerations and adjustment facility. Stochastic techniques provide the best (and nearly identical) numerical solutions. This is mainly due to their increased facility to introduce “a priori” information about the expected solution. As a counterpart, stochastic techniques are conceptually more complex, more difficult to implement, and normally involve more elaborate adjustment procedures. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:1671 / 1708
页数:38
相关论文
共 50 条
  • [21] Two-dimensional chromatography as a tool for studying band broadening in size-exclusion chromatography
    Popovici, ST
    van der Horst, A
    Schoenmakers, PJ
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (13) : 1457 - 1466
  • [22] A SIMPLIFIED SOLUTION OF TUNG INSTRUMENTAL SPREADING EQUATION IN SIZE-EXCLUSION CHROMATOGRAPHY
    MORI, S
    SUZUKI, T
    WADA, A
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 : 61 - 75
  • [23] CORRECTION FOR INTERDETECTOR VOLUME IN SIZE-EXCLUSION CHROMATOGRAPHY (SEC)
    PIGEON, MG
    RUDIN, A
    JOURNAL OF APPLIED POLYMER SCIENCE, 1995, 57 (03) : 287 - 301
  • [24] Molar mass distributions of linear homopolymers by size exclusion chromatography with light scattering detection: A method for automatic band broadening correction
    Clementi, Luis A.
    Yossen, Mariana M.
    Vega, Jorge R.
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1595 : 136 - 143
  • [25] SIZE-EXCLUSION CHROMATOGRAPHY OF POLYELECTROLYTES - COMPARISON WITH THEORY
    DUBIN, PL
    LARTER, RM
    WU, CJ
    KAPLAN, JI
    JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (18): : 7243 - 7250
  • [26] SIZE-EXCLUSION CHROMATOGRAPHY FTIR TECHNIQUES FOR POLYMER ANALYSIS
    WILLIS, JN
    DWYER, JL
    LIU, MX
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 133 - ANYL
  • [27] Band broadening function in size exclusion chromatography of polymers:: Review of some recent developments
    Meira, Gregorio
    Netopilik, Milog
    Potschka, Martin
    Schnoell-Bitai, Irene
    Vega, Jorge
    MACROMOLECULAR SYMPOSIA, 2007, 258 : 186 - 197
  • [28] Contribution of the polymer standards' polydispersity to the observed band broadening in size-exclusion chromatography
    Vander Heyden, Y
    Popovici, ST
    Staal, BBP
    Schoenmakers, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (01) : 1 - 15
  • [29] Problems connected with band-broadening in size-exclusion chromatography with dual detection
    Netopilík, M
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2003, 56 (1-3): : 79 - 93
  • [30] DETERMINATION OF THE BAND BROADENING FUNCTION IN SIZE EXCLUSION CHROMATOGRAPHY WITH LIGHT-SCATTERING DETECTION
    Yossen, Mariana M.
    Vega, Jorge R.
    Chang, Taihyun
    Meira, Gregorio R.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) : 79 - 94