APPLICATION OF THE MBWC 2-DIMENSIONAL POSITION READOUT TECHNIQUE TO A MULTIWIRE PROPORTIONAL COUNTER

被引:24
|
作者
MIZOGAWA, T
SATO, M
AWAYA, Y
机构
[1] INST PHYS & CHEM RES,WAKO,SAITAMA 35101,JAPAN
[2] NAGAOKA UNIV TECHNOL,NAGAOKA,NIIGATA 940,JAPAN
关键词
D O I
10.1016/0168-9002(95)00682-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A two-dimensional position readout technique named ''modified backgammon method with weighted coupling capacitors (MBWC)'' has been applied to a multiwire proportional counter, and its image linearity and position resolution have been investigated. One of two types of the technique, the three-output MBWC method, has shown several kinds of image deformations. The sources of the deformation and the way to avoid them are clarified. On the other hand, an essentially linear image has been readily obtained by adopting the other type (four-output MBWC method). The overall spatial resolution parallel to the wire direction and the spatial resolution of the position encoding cathode for the direction perpendicular to the wire have been investigated with Fe K X-rays. The best values obtained are 130 and 110 mu m (FWHM), respectively, which correspond to similar to 600 x 600 pixels.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 50 条
  • [21] POSITION READOUT BY CHARGE DIVISION IN LARGE 2-DIMENSIONAL DETECTORS
    ALBERI, JL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 188 - 194
  • [22] EFFICIENCY AND POSITION-RESOLUTION OF 2-DIMENSIONAL POSITION-SENSITIVE MULTIWIRE PROPORTION COUNTERS
    BOLGER, JE
    BRAITHWAITE, WJ
    HOLTKAMP, DB
    KALLNE, J
    THIESSEN, HA
    MORRIS, CL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (09): : 1169 - 1169
  • [23] MULTIWIRE PROPORTIONAL COUNTER TECHNIQUE FOR STANDARDIZATION OF LOW-ENERGY PHOTON SOURCES
    CHEW, WM
    MCGEORGE, JC
    FINK, RW
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (03): : 499 - 501
  • [24] SCHWARZ METHOD APPLICATION TO ANALYSIS OF 2-DIMENSIONAL PERIODICAL MULTIWIRE LINES
    RODYGIN, LV
    RODYGINA, LS
    RADIOTEKHNIKA I ELEKTRONIKA, 1974, 19 (08): : 1615 - 1620
  • [25] A large area two-dimensional position sensitive multiwire proportional detector
    de Moura, MM
    Suaide, AAP
    Souza, FA
    Alonso, EE
    Fujii, RJ
    Meyknecht, AB
    Added, N
    Aissaoui, N
    Cardenas, WHZ
    Ferraretto, MD
    Schnitter, U
    Szanto, EM
    de Toledo, AS
    Yamamura, MS
    Carlin, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 433 (03): : 623 - 629
  • [27] A DELAY-LINE POSITION READOUT FOR A HEAVY-ION PROPORTIONAL COUNTER
    VANENGELEN, CPM
    BLAAUBOER, RO
    KAMERMANS, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 219 (03): : 529 - 533
  • [28] A HARDWARE READOUT SYSTEM FOR A CURVED ONE-DIMENSIONAL POSITION-SENSITIVE PROPORTIONAL COUNTER .1. ELECTRONICS
    DUIJN, JH
    VANEIJK, CWE
    HOLLANDER, RW
    KREUGER, R
    SLOOF, GW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (2-3): : 486 - 492
  • [29] Automatic method to manufacture 2D Multiwire Proportional Counter frames
    Martinez, J. C.
    Ramos-Lerate, I.
    Fernandez, F.
    Beltran, D.
    Bordas, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 41 - 43
  • [30] A HARDWARE READOUT SYSTEM FOR A CURVED ONE-DIMENSIONAL POSITION-SENSITIVE PROPORTIONAL COUNTER .2. SOFTWARE CORRECTION OF RECORDED SPECTRA
    DUIJN, JH
    VANEIJK, CWE
    HOLLANDER, RW
    KREUGER, R
    SLOOF, GW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (2-3): : 493 - 496