Circular dichroic spectroscopy has been used to study the effect of pH, guanidinium hydrochloride concentration and temperature on the conformation of the fungal subtilisin-like proteinase K and the bacterial DY. The ellipticity of the bands in the far ultraviolet region remains almost unchanged in the pH range 3.0-11.0 (PMS-proteinase K) and 5.0-10.0 (PMS-subtilisin DY). The same ranges of pH stability were determined from the pH dependence of the near ultraviolet dichroic spectra. Hence the changes in the tertiary and secondary structure occur in parallel. Proteinase K is considerably more stable at acidic and somewhat more stable at alkaline pH than subtilisin DY. At neutral pH proteinase K is more resistant to denaturation by guanidinium hydrochloride than is subtilisin DY. The midpoints of the denaturation curves were 6.2 M and 3.2 M guanidinium, respectively. The thermal unfolding of proteinase K occurred at a higher temperature than for subtilisin DY, the transition midpoints being 65-degrees and 48-degrees, respectively. Thus proteinase K is overall a much more robust molecule than subtilisin DY, showing greater resistance to all three forms of denaturation. The differences in the stability of the two proteinases can be partly explained by differences in their calcium binding sites.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
  • [31] X-RAY PHOTOELECTRON SPECTROSCOPIC STUDIES OF SOLID ELECTROLYTES
    DICKINSON, T
    POVEY, AF
    SHERWOOD, PMA
    JOURNAL OF SOLID STATE CHEMISTRY, 1975, 13 (03) : 237 - 244
  • [32] INSITU X-RAY PHOTOELECTRON SPECTROSCOPIC STUDIES OF CARBOCATIONS
    JOHNSON, SA
    CLARK, DT
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (13) : 4112 - 4117
  • [33] X-RAY PHOTOELECTRON SPECTROSCOPIC STUDIES OF ELECTROACTIVE POLYMERS
    KANG, ET
    NEOH, KG
    TAN, KL
    ADVANCES IN POLYMER SCIENCE, 1993, 106 : 135 - 190
  • [34] X-RAY ABSORPTION SPECTROSCOPIC STUDIES OF CHALCOPYRITE MINERAL
    HEMACHANDRAN, K
    CHETAL, AR
    JOSHI, G
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1987, 141 (02): : 441 - 445
  • [36] X-RAY PHOTOELECTRON SPECTROSCOPIC STUDIES OF KAOLINITE AND MONTMORILLONITE
    BARR, TL
    SEAL, S
    HE, H
    KLINOWSKI, J
    VACUUM, 1995, 46 (12) : 1391 - 1395
  • [37] In situ combined X-ray absorption spectroscopic and X-ray diffractometric studies of solid catalysts
    Sankar, G
    Thomas, JM
    TOPICS IN CATALYSIS, 1999, 8 (1-2) : 1 - 21
  • [38] S K-EDGE X-RAY ABSORPTION AND X-RAY PHOTOELECTRON SPECTROSCOPIC STUDIES OF CS2 ADSORPTION ON NI(100)
    YOKOYAMA, T
    YAGI, S
    TAKATA, Y
    SATO, H
    ASAHI, T
    OHTA, T
    KITAJIMA, Y
    SURFACE SCIENCE, 1992, 274 (02) : 222 - 230
  • [39] Simultaneous COLTRIMS and X-ray spectroscopic studies relevant to cometary, planetary, and heliospheric X-ray emission
    Ali, Rami
    ATOMIC PROCESSES IN PLASMAS, 2007, 926 : 216 - 225
  • [40] X-ray absorption spectroscopy and X-ray photoelectron spectroscopy studies of CaSO4:Dy thermoluminescent phosphors
    Bakshi, A. K.
    Jha, S. N.
    Olivi, L.
    Phase, D. M.
    Kher, R. K.
    Bhattacharyya, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 264 (01): : 109 - 116