Reliability and validity of an electronic dynamometer for measuring grip strength

被引:30
|
作者
Allen, Deborah [1 ]
Barnett, Fiona [1 ]
机构
[1] James Cook Univ, Occupat Therapy Discipline, Townsville, Qld, Australia
来源
INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION | 2011年 / 18卷 / 05期
关键词
dynamometer; grip strength; test-retest;
D O I
10.12968/ijtr.2011.18.5.258
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Aims: This article describes a study aiming to establish the concurrent validity and test-retest reliability of the Biometrics E-LINK EP9 electronic dynamometer. Methods: Grip strength testing was performed on 49 healthy participants. Three trials were completed for the right and left hands on the Biometrics and Jamar dynamometers, using a repeated measures design. Data was compared and used to establish concurrent validity of the Biometrics dynamometer. Fifteen participants repeated the testing a week later, for test-retest reliability of the Biometrics dynamometer. Findings: The Biometrics E-LINK EP9 evaluation system was found to have excellent validity (ICC 0.983-0.986). However, a small but statistically significant difference between the right hand grip strength scores of the Biometrics (31.65 +/- 8.89) and Jamar (30.44 +/- 9.49) dynamometer was revealed (p <= 0.05). Test-retest reliability of the Biometrics system proved excellent, with ICC scores of 0.986 for the left hand and 0.996 for the right hand. Conclusions: The results indicate that the Biometrics E-LINK EP9 evaluation system is valid, reliable and comparable to the Jamar hydraulic dynamometer, when used for measuring grip strength with the second handle position. However, due to the statistically significant differences found for the right hand grip strength scores, therapists should exercise caution when interchanging instruments.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [31] Concordance of grip strength measurement between a digital handheld dynamometer and a Hydraulic dynamometer
    Segura-Duarte, Amor A.
    Mendez-Suarez, Gerardo
    Burgos-Morelos, Laura P.
    Rivera-Sanchez, Jose J.
    GACETA MEDICA DE MEXICO, 2024, 160 (03): : 322 - 326
  • [32] REVISED NORMATIVE VALUES FOR GRIP STRENGTH WITH THE JAMAR DYNAMOMETER
    Peters, M. J. H.
    van Nes, S., I
    Vanhoutte, E. K.
    Bakkers, M.
    van Doorn, P. A.
    Merkies, I. S. J.
    Faber, C. G.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2011, 16 : S107 - S108
  • [33] Development of a Dynamometer to Measure Grip Strength of Each Finger
    Makino, Koji
    Sato, Nobutaka
    Fujita, Koji
    Kanagawa, Takaiki
    Miyamamoto, Masaya
    Sasaki, Toru
    Haro, Hirotaka
    Kondo, Yasuo
    Terada, Hidetsugu
    2018 IEEE 27TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2018, : 1100 - 1105
  • [34] Which setting of the dynamometer provides maximal grip strength?
    Firrell, JC
    Crain, GM
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (03): : 397 - 401
  • [35] Revised normative values for grip strength with the Jamar dynamometer
    Peters, Martine J. H.
    van Nes, Sonja I.
    Vanhoutte, Els K.
    Bakkers, Mayienne
    van Doorn, Pieter A.
    Merkies, Ingemar S. J.
    Faber, Catharina G.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2011, 16 (01) : 47 - 50
  • [36] Reliability, validity and usability of the K-force® grip dynamometer to evaluate handgrip-strength in patients with intensive care unit-acquired weakness
    van Iperen, Ingrid D.
    Stegink, Daphne
    Tempert-de Haan, Barbara L.
    Flim, Marleen
    van der Stoep, Robert
    Spronk, Peter E.
    CLINICAL REHABILITATION, 2024,
  • [37] Development of an integrated digital hand grip dynamometer and norm of hand grip strength
    Chang, Ho
    Chen, Chih-Hao
    Huang, Tung-Sun
    Tai, Chun-Yen
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S611 - S617
  • [38] Reliability, validity and usability of the K-force® grip dynamometer to evaluate handgrip-strength in patients with intensive care unit-acquired weakness
    van Iperen, Ingrid D.
    Stegink, Daphne
    Tempert- de Haan, Barbara L.
    Flim, Marleen
    van der Stoep, Robert
    Spronk, Peter E.
    CLINICAL REHABILITATION, 2025, 39 (01) : 67 - 77
  • [39] Reliability and Validity of Seated Hip Extensor Strength Measurement by Handheld Dynamometer in Older Adults
    Seko, Toshiaki
    Mori, Mitsuru
    Ohnishi, Hirofumi
    Himuro, Nobuaki
    Takahashi, Yui
    Kumamoto, Tsuneo
    Ito, Toshikazu
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2019, 42 (04) : E39 - E44
  • [40] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228