PERFORMANCE OF A TIME-OF-FLIGHT SILICON STRIP TELESCOPE IN THE TEMPERATURE-RANGE 20-DEGREES-C TO 55-DEGREES-C

被引:6
|
作者
CODINO, A [1 ]
BRUNETTI, MT [1 ]
FEDERICO, C [1 ]
GRIMANI, C [1 ]
MACCHIAIOLO, T [1 ]
MENICHELLI, M [1 ]
MINELLI, G [1 ]
MIOZZA, M [1 ]
PLOUIN, F [1 ]
机构
[1] CENS,NATL SATURNE LAB,F-91191 GIF SUR YVETTE,FRANCE
关键词
D O I
10.1016/0168-9002(95)00492-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cold silicon strip telescope for time-of-flight determination operating at -55 degrees C has been tested using a hadron beam at Saturne II, Saclay. We present performance tests of the telescope, the time-of-flight distributions between pairs of silicon hodoscopes and their dependence on temperature. A detailed description of the apparatus, the refrigerator system and the calibration procedures is also reported. A linear relationship between the time resolution and the temperature of the apparatus is measured. An improvement of a factor 2 in the time-of-flight resolution is observed when the temperature decreases from +20 degrees C to -55 degrees C.