PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES

被引:59
|
作者
CSOREGI, E [1 ]
GORTON, L [1 ]
MARKOVARGA, G [1 ]
TUDOS, AJ [1 ]
KOK, WT [1 ]
机构
[1] UNIV AMSTERDAM, DEPT ANALYT CHEM, 1018 WV AMSTERDAM, NETHERLANDS
关键词
D O I
10.1021/ac00093a012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mediatorless amperometric microbiosensors, prepared by immobilizing two different peroxidases [horseradish peroxidase (HRP) or peroxidase from Arthromyces ramosus (ARP)] on high-modulus-type carbon fibers, were applied for detection in flowing solution. The preparation and performance of the enzyme-modified carbon fibers were studied. An electrochemical flow-through cell containing the fiber electrode was evaluated and optimized. The influence of the electrode dimensions and the flow rate on the sensitivity and the sample dispersion in the cell was studied by use of bare and enzyme-modified electrodes. The peak broadening was found to be determined by the geometry of the now cell. The response time of the enzyme-modified electrode was short (<4 s) and did not contribute significantly to the peak broadening. When operated in a flow injection (FI) system, hydrogen peroxide and organic peroxides could be detected with the enzyme-modified electrodes at an applied potential of -0.05 V vs Ag/AgCl. With the optimized cell low noise levels were obtained (<5 pA), allowing detection limits of 0.3, 6.0, and 20.0 mu M for hydrogen peroxide, cumol hydroperoxide, and 2-butanone peroxide, respectively.
引用
收藏
页码:3604 / 3610
页数:7
相关论文
共 44 条
  • [11] Flow-through porous carbon-fiber electrode for electro-deposition
    Wang, Lixin
    Xi, Deli
    Hua, Tingting
    Li, Zhou
    Huagong Yejin/Engineering Chemistry & Metallurgy, 1997, 18 (02): : 102 - 107
  • [12] ELECTRODE-KINETICS OF THE OXIDATION OF HYDROGEN-PEROXIDE AT PRETREATED GLASSY-CARBON AND CARBON-FIBER ELECTRODES
    AOKI, K
    ISHIDA, M
    TOKUDA, K
    HASEBE, K
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 251 (01): : 63 - 71
  • [13] PEROXIDASE FERROCENE MODIFIED CARBON PASTE ELECTRODE AS AN AMPEROMETRIC SENSOR FOR THE HYDROGEN-PEROXIDE ASSAY
    SANCHEZ, PD
    ORDIERES, AJM
    GARCIA, AC
    BLANCO, PT
    ELECTROANALYSIS, 1991, 3 (4-5) : 281 - 285
  • [14] CATHODIC REACTION OF DISSOLVED-OXYGEN AND HYDROGEN-PEROXIDE AT LIQUID FLOW-THROUGH ELECTRODES
    ICHINO, H
    YAMASHIT.M
    KUBOKAWA, M
    NIPPON KAGAKU KAISHI, 1974, (04) : 664 - 668
  • [15] Determination of hydrogen peroxide released from cancer cells by a Fe-Organic framework/horseradish peroxidase-modified electrode
    Jiang, Tian
    Sun, Xiuxiu
    Wei, Lingli
    Li, Maoguo
    ANALYTICA CHIMICA ACTA, 2020, 1135 (1135) : 132 - 141
  • [16] Enhanced selectivity and stability of ruthenium purple-modified carbon fiber microelectrodes for detection of hydrogen peroxide in brain tissue
    Ledo, Ana
    Fernandes, Eliana
    Brett, Christopher M. A.
    Barbosa, Rui M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 311
  • [17] DEGRADATION OF TRICHLOROETHYLENE IN WATER + ACETONITRILE BY FLOW-THROUGH ELECTROLYSIS USING A CARBON-FIBER ELECTRODE
    NAGAOKA, T
    YAMASHITA, J
    KANEDA, M
    OGURA, K
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 335 (1-2): : 187 - 195
  • [18] AN ENZYME ELECTRODE FOR HYDROGEN-PEROXIDE DETECTION BASED ON PEROXIDASE IMMOBILIZED ON A GLASSY-CARBON ELECTRODE
    NARASAIAH, D
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (06): : 415 - 422
  • [19] Flow-through Micro Sensor Using Immobilized Peroxidase with Chemiluminometric FIA System for Determining Hydrogen Peroxide
    Nobutoshi Kiba
    Toyonari Tokizawa
    Sayaka Kato
    Masaki Tachibana
    Kazue Tani
    Hitoshi Koizumi
    Masaharu Edo
    Eiichi Yonezawa
    Analytical Sciences, 2003, 19 : 823 - 827
  • [20] Flow-through micro sensor using immobilized peroxidase with chemiluminometric FIA system for determining hydrogen peroxide
    Kiba, N
    Tokizawa, T
    Kato, S
    Tachibana, M
    Tani, K
    Koizumi, H
    Edo, M
    Yonezawa, E
    ANALYTICAL SCIENCES, 2003, 19 (06) : 823 - 827