ARTERIOVENOUS-FISTULAS IN RENAL-TRANSPLANTS - COLOR DOPPLER ULTRASOUND OBSERVATIONS

被引:0
|
作者
DEANE, C
COWAN, N
GILES, J
WALTERS, H
RIFKIN, I
SEVERN, A
PARSONS, V
机构
[1] DULWICH HOSP, KINGS COLL, SCH MED & DENT, DEPT RADIOL, LONDON SE22 8PT, ENGLAND
[2] DULWICH HOSP, KINGS COLL, SCH MED & DENT, DEPT RENAL MED, LONDON SE22 8PT, ENGLAND
关键词
DOPPLER ULTRASOUND; RENAL TRANSPLANTATION; ARTERIOVENOUS FISTULA; RENAL ARTERY STENOSIS; RENAL VEIN STENOSIS;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One hundred twenty-six new renal transplants were scanned regularly with color Doppler ultrasound (CDU). In 22 (17.5%) of the grafts there was evidence of postbiopsy arteriovenous (AV) fistula during the first 6 months postoperatively. In 14 cases the fistula closed spontaneously. In the remaining eight, the fistula was still present up to 24 months later (four cases) or until the graft failed (four cases). Additionally, 163 established grafts were scanned for evidence of vascular abnormality. AV fistulas were observed in 15 grafts (8%). Circulatory complications of fistulas observed include vascular steal and a possible association with graft vein and artery stenosis.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 50 条
  • [11] DOPPLER AND COLOR DOPPLER ULTRASONOGRAPHY IN RENAL-TRANSPLANTS - CHRONIC REJECTION
    DEANE, C
    JOURNAL OF CLINICAL ULTRASOUND, 1992, 20 (08) : 539 - 544
  • [12] COLOR FLOW AND IMAGE-DIRECTED DOPPLER ULTRASOUND EVALUATION OF IATROGENIC ARTERIOVENOUS-FISTULAS IN THE GROIN
    ROUBIDOUX, MA
    HERTZBERG, BS
    CARROLL, BA
    HEDGEPETH, CA
    JOURNAL OF CLINICAL ULTRASOUND, 1990, 18 (06) : 463 - 469
  • [13] NEW OBSERVATIONS IN RENAL-TRANSPLANTS USING ULTRASOUND
    CONRAD, MR
    DICKERMAN, R
    LOVE, IL
    CURRY, T
    PETERS, P
    HULL, A
    LERMAN, M
    HELDERMAN, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (05) : 851 - 855
  • [14] EVALUATION OF DOPPLER ULTRASOUND IN PRIMARY NONFUNCTION OF RENAL-TRANSPLANTS
    PHILLIPS, AO
    DEANE, C
    ODONNELL, P
    BEWICK, M
    HILLIS, AN
    CLINICAL TRANSPLANTATION, 1994, 8 (02) : 83 - 86
  • [15] COLOR DOPPLER ULTRASOUND ASSESSMENT OF ARTERIOVENOUS HEMODIALYSIS FISTULAS
    NONNASTDANIEL, B
    MARTIN, RP
    LINDERT, O
    MUGGE, A
    SCHAEFFER, J
    SOCHTIG, E
    GALANSKI, M
    KOCH, KM
    DANIEL, WG
    VANDERLIETH, H
    LANCET, 1992, 339 (8786): : 143 - 145
  • [16] QUANTITATIVE DOPPLER AND ULTRASOUND MEASUREMENTS IN SURGICALLY PERFORMED ARTERIOVENOUS-FISTULAS OF THE ARM
    FORSBERG, L
    HOLMIN, T
    LINDSTEDT, E
    ACTA RADIOLOGICA-DIAGNOSIS, 1980, 21 (06): : 769 - 776
  • [17] DOPPLER SONOGRAPHY OF RENAL-TRANSPLANTS
    CAPEK, P
    RUBIN, JM
    ALPERN, MB
    ROCHER, LL
    WASKERWITZ, JA
    INVESTIGATIVE RADIOLOGY, 1987, 22 (09) : S19 - S19
  • [18] BILATERAL CONGENITAL RENAL ARTERIOVENOUS-FISTULAS
    ULLIAN, ME
    MOLITORIS, BA
    CLINICAL NEPHROLOGY, 1987, 27 (06) : 293 - 297
  • [19] A RADIOISOTOPE-DILUTION METHOD IN COMPARISON WITH DOPPLER ULTRASOUND PARAMETERS IN ARTERIOVENOUS-FISTULAS
    WEISE, A
    RIEDHAMMER, HH
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1987, 16 (11) : 471 - 478
  • [20] DIALYSIS ARTERIOVENOUS FISTULAS: THE CRITICAL ROLE OF COLOR DOPPLER ULTRASOUND
    Verbeeck, N.
    Prospert, F.
    McIntyre, D.
    Lamy, S.
    JBR-BTR, 2011, 94 (05): : 266 - 277