PHOTOELASTIC ISODYNES - NEW TYPE OF STRESS-MODULATED LIGHT INTENSITY DISTRIBUTION

被引:10
|
作者
PINDERA, JT
MAZURKIEWICZ, S
机构
[1] UNIV WATERLOO,DEPT CIVIL ENGN,DIV SOLID MECH,WATERLOO N2L 3G1,ONTARIO,CANADA
[2] TECH UNIV CRACOW,DEPT MECH ENG,CRACOW,POLAND
关键词
D O I
10.1016/0093-6413(77)90034-9
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
引用
收藏
页码:247 / 252
页数:6
相关论文
共 34 条
  • [21] Size distribution of polycyclic aromatic hydrocarbons in space: an old new light on the 11.2/3.3 μm intensity ratio
    Lemmens, Alexander K.
    Mackie, Cameron J.
    Candian, Alessandra
    Lee, Timothy M. J.
    Tielens, Alexander G. G. M.
    Rijs, Anouk M.
    Buma, Wybren Jan
    FARADAY DISCUSSIONS, 2023, 245 (00) : 380 - 390
  • [22] QUALITY, INTENSITY AND FIELD DISTRIBUTION OF RADIATION EMITTED FROM A NEW TYPE OF LOW VOLTAGE ROENTGEN THERAPY TUBE
    LEWIS, HM
    MUTSCHELLER, A
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1949, 12 (06) : 325 - 330
  • [23] Stress Distribution of a New Type of Perforated Implants in Femur Neck Fracture: Finite Element Model
    Jafarov, Afgan
    Ali-Zadeh, Chingiz
    Ozer, Zafer
    Mamedov, Amirullah M.
    Ozbay, Ekmel
    3RD INTERNATIONAL CONFERENCE ON RHEOLOGY AND MODELING OF MATERIALS (IC-RMM3), 2018, 1045
  • [24] The measurement of III type crack tip stress intensity factor by white light digital image analysis in frequency domination area
    Ji, Xin-Hua
    Yang, Xin-Wei
    Chen, Jin-Long
    Guangxue Jishu/Optical Technique, 2008, 34 (05): : 764 - 767
  • [25] THEORY OF SECOND-HARMONIC GENERATION IN COLLIMATED LIGHT-BEAMS WITH GAUSSIAN DISTRIBUTION OF LIGHT-INTENSITY FOR INTERACTION OF TYPE O+E-]E
    CHMELA, P
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1974, B 24 (05) : 506 - 521
  • [26] THEORY OF SECOND-HARMONIC GENERATION IN FOCUSED LIGHT-BEAM OF FUNDAMENTAL FREQUENCY WITH GAUSSIAN DISTRIBUTION OF LIGHT-INTENSITY UNDER INTERACTION OF TYPE O + O -] E
    CHMELA, P
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1974, B 24 (01) : 1 - 23
  • [27] Effects of interportal error on dose distribution in patients undergoing breath-holding intensity-modulated radiotherapy for pancreatic cancer: evaluation of a new treatment planning method
    Takakura, Toru
    Nakamura, Mitsuhiro
    Shibuy, Keiko
    Nakata, Manabu
    Nakamura, Akira
    Yukinori, Matsuo
    Shiinoki, Takeshi
    Higashimura, Kyoji
    Teshima, Teruki
    Hiraoka, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05): : 43 - 51
  • [28] Analysis of the influence of a new type of buccal tube base mesh design on the adhesive layer stress distribution and bond strength
    Liu, Yang
    Zhou, Shan
    Han, Xiao
    Yan, Chengcheng
    Lei, Zhenglong
    Wang, Xiaofeng
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2020, 34 (18) : 2011 - 2030
  • [29] New Inference for Constant-Stress Accelerated Life Tests With Weibull Distribution and Progressively Type-II Censoring
    Wang, Bing Xing
    Yu, Keming
    Sheng, Zhuo
    IEEE TRANSACTIONS ON RELIABILITY, 2014, 63 (03) : 807 - 815
  • [30] New type of acoustic filter using periodic polymer layers for measuring audio signal components excited by amplitude-modulated high-intensity ultrasonic waves
    Toda, M
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 2005, 53 (10): : 930 - 941