A SYSTEM FOR NONINVASIVELY MEASURING BLOOD-PRESSURE ON A TREADMILL

被引:8
|
作者
AU, TCP
WEBSTER, JG
TAN, BT
机构
[1] Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI 53706-1691
关键词
BLOOD PRESSURE; KOROTKOFF SOUNDS; MOTION ARTIFACTS; SOUND SPECTRUM; TREADMILL EXERCISE; AUSCULTATORY METHOD; STRESS TESTING; SIGNAL TO NOISE RATIO; ELECTRONIC FILTER; FREQUENCY ANALYSIS;
D O I
10.1088/0967-3334/16/4/007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Measurement of signal to artifact ratio yielded optimal frequencies for a Korotkoff-based automatic system for measuring blood pressure on a treadmill. Maximal Korotkoff sounds occurred just above the crease of the elbow over the brachial artery. Output of a piezoelectric microphone and charge amplifier was measured during treadmill exercise for frequency bands from 8 to 57 Hz. An automatic system filtered output from 40 to 45 Hz, rectified it, then compared it to a threshold that had fixed and exponentially decaying components. For five subjects, the system decisions of systolic and diastolic pressures compared well with those of two observers using stethoscopes. The system shows promise for improved measurements of blood pressure during treadmill exercise.
引用
收藏
页码:273 / 285
页数:13
相关论文
共 50 条
  • [31] EVALUATION OF BLOOD-PRESSURE MEASURING DEVICES
    OBRIEN, E
    ATKINS, N
    MEE, F
    OMALLEY, K
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 1993, 15 (06) : 1087 - 1097
  • [32] NEW INSTRUMENTS FOR MEASURING BLOOD-PRESSURE
    LABARTHE, DR
    DRUGS, 1976, 11 : 48 - 57
  • [33] VALIDATION OF BLOOD-PRESSURE MEASURING DEVICES
    OBRIEN, E
    PADFIELD, P
    BLAND, M
    ATKINS, N
    COATS, A
    PETRIE, J
    ALTMAN, D
    LITTLER, W
    DESWIET, M
    JOURNAL OF CLINICAL MONITORING, 1995, 11 (04): : 257 - 257
  • [34] VALIDATION OF BLOOD-PRESSURE MEASURING SYSTEMS
    REID, JL
    JOURNAL OF HYPERTENSION, 1993, 11 (06) : R1 - R2
  • [35] THE MEASURING OF BLOOD-PRESSURE DURING PREGNANCY
    VILLAR, J
    REPKE, J
    MARKUSH, L
    CALVERT, W
    RHOADS, G
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 161 (04) : 1019 - 1024
  • [36] MEASURING BLOOD-PRESSURE - WHICH ARM
    PANAYIOTOU, BN
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (17): : 1343 - 1343
  • [37] COMPARISON OF METHODS OF MEASURING BLOOD-PRESSURE
    ALTMAN, DG
    BLAND, JM
    JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1986, 40 (03) : 274 - 275
  • [38] ESTIMATES OF BLOOD-PRESSURE VARIABILITY IN ADOLESCENTS USING AN AUTOMATIC BLOOD-PRESSURE MEASURING DEVICE
    LOMBARDI, DA
    GILLMAN, MW
    ELLISON, RC
    HOSMER, DW
    PULEO, EM
    JOURNAL OF HUMAN HYPERTENSION, 1994, 8 (06) : 441 - 443
  • [39] AUTOMATIC BLOOD-PRESSURE MONITORING WITH AN OSCILLOMETRIC MEASURING SYSTEM - ACCURACY AND ACCEPTABILITY
    KOLLING, K
    KRAUS, F
    HAASE, HU
    REDL, A
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1992, 21 (10) : 448 - 452
  • [40] DETERMINATION OF FREQUENCY PROPERTIES OF MANOMETRIC SYSTEM FOR MEASURING BLOOD-PRESSURE DIRECTLY
    PETRIK, V
    BROZMAN, B
    SEDLAK, P
    CALJA, J
    PHYSIOLOGIA BOHEMOSLOVACA, 1975, 24 (05): : 462 - 462