CORRECTIONS FOR ACCIDENTAL COINCIDENCES AND ATTENUATION IN MAXIMUM-LIKELIHOOD IMAGE-RECONSTRUCTION FOR POSITRON-EMISSION TOMOGRAPHY

被引:112
|
作者
POLITTE, DG
SNYDER, DL
机构
[1] Washington University, St. Louis, MO
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
D O I
10.1109/42.75614
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A new method has been developed and tested for correcting for the effects of accidental coincidences and photon attenuation in positron-emission tomography. A mathematical model is used for these effects as the basis for the development. The corrections are incorporated into the iterations of an expectation-maximization algorithm for numerically producing the maximum-likelihood estimate of a distribution of radioactivity within a patient. We have found the images reconstructed with this new procedure to be unbiased and to exhibit lower variance than those reconstructed from precorrected data.
引用
收藏
页码:82 / 89
页数:8
相关论文
共 50 条
  • [1] A STUDY OF LEAST-SQUARES AND MAXIMUM-LIKELIHOOD FOR IMAGE-RECONSTRUCTION IN POSITRON EMISSION TOMOGRAPHY
    OSULLIVAN, F
    ANNALS OF STATISTICS, 1995, 23 (04): : 1267 - 1300
  • [2] MAXIMUM-LIKELIHOOD IMAGE-RECONSTRUCTION FOR SPECT
    VISHAMPAYAN, S
    STAMOS, J
    MAYANS, R
    KORAL, K
    CLINTHORNE, N
    ROGERS, WL
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P20 - P20
  • [3] Evaluation of maximum-likelihood based attenuation correction in positron emission tomography
    Nuyts, J
    Dupont, P
    Stroobants, S
    Maes, A
    Mortelmans, L
    Suetens, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1136 - 1141
  • [4] Evaluation of maximum-likelihood based attenuation correction in positron emission tomography
    Nuyts, J.
    Dupont, P.
    Stroobants, S.
    Maes, A.
    Mortelmans, L.
    Suetens, P.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1836 - 1841
  • [6] EVALUATION OF THE MAXIMUM-LIKELIHOOD METHOD FOR RECONSTRUCTION IMAGES IN POSITRON EMISSION TOMOGRAPHY
    MINTUN, MA
    GORMAN, J
    SWIFT, AG
    SNYDER, DL
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P20 - P20
  • [7] BAYESIAN IMAGE-RECONSTRUCTION IN POSITRON EMISSION TOMOGRAPHY
    CHEN, CT
    JOHNSON, VE
    WONG, WH
    HU, XP
    METZ, CE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 636 - 641
  • [8] ON THE PERFORMANCE OF MAXIMUM-LIKELIHOOD RECONSTRUCTIONS IN POSITRON EMISSION TOMOGRAPHY
    VERMEULEN, FL
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 397 : 274 - 279
  • [9] Maximum likelihood iterative reconstruction for attenuation correction in positron emission tomography.
    Glatting, G
    Weller, R
    Reske, SN
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 181P - 182P
  • [10] A MODIFIED MAXIMUM-LIKELIHOOD ALGORITHM SUITABLE FOR VOLUME IMAGE-RECONSTRUCTION
    DAUBE, ME
    MUEHLLEHNER, G
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P89 - P89