ELECTROCHEMICAL SENSOR OF NITRITE BASED ON AN INORGANIC FILM-MODIFIED GLASSY-CARBON ELECTRODE

被引:8
|
作者
GAO, ZQ
ZI, MX
ZHANG, Y
WANG, GQ
ZHAO, ZF
机构
[1] HENAN UNIV,DEPT CHEM,KAIFENG 475001,PEOPLES R CHINA
[2] WUHAN UNIV,DEPT PHYS,WUHAN,PEOPLES R CHINA
[3] WUHAN UNIV,DEPT CHEM,WUHAN,PEOPLES R CHINA
关键词
CHEMICALLY MODIFIED ELECTRODE; ELECTROCHEMICAL SENSOR; FLOW INJECTION ANALYSIS; NITRITE; HEPTACYANONITROSYLFERRATE;
D O I
10.1007/BF01240168
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrocatalysis of nitrite in solutions at an inorganic film modified glassy carbon electrode was studied. The modifier was an electrodeposited thin inorganic film of the copper-heptacyanonitrosylferrate (CuHNF). Cyclic voltammetry of the modified electrode in a nitrite solution revealed that both oxidation and reduction of nitrite were catalyzed and the electrocatalytic currents were controlled by the diffusion of nitrite. Voltammetric and amperometric responses were investigated. When applied as an amperometric sensor in a flow injection system, the modified electrode permitted detection at -0.55 V, over 500 mV lower than at the naked electrode surface. A linear response range extending from 1 x 10(-6) to 1 x 10(-3) M nitrite was obtained, with a detection limit of 3 x 10(-7) M. The relative standard deviation for 50 repetitive injections with a 5 x 10(-5) M nitrite solution was less than 4%. The procedure was applied to the determination of nitrite in saliva and nitrate.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [21] A REAGENTLESS ALCOHOL SENSOR-BASED ON THIONINE-TDI MODIFIED GLASSY-CARBON ELECTRODE
    YU, AM
    HAN, JL
    YANG, KS
    CHEN, HY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (08): : 1204 - 1206
  • [22] Electrochemical sensor based on graphene oxide/PEDOT:PSS composite modified glassy carbon electrode for environmental nitrite detection
    Anindya, Weni
    Wahyuni, Wulan Tri
    Rafi, Mohamad
    Putra, Budi Riza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (03):
  • [23] Nitrite Sensor Based on Poly-salicylaldehyde Para-aminobenzoic Acid Film Modified Glassy Carbon Electrode
    Wang, Yuchun
    Liu, Zhaorong
    Tan, Chao
    SENSORS AND MATERIALS, 2021, 33 (05) : 1717 - 1725
  • [24] Electrochemical Sensor Based on Glassy-Carbon Electrode Modified with Dual-Ligand EC-MOFs Supported on rGO for BPA
    Ye, Rui-Hong
    Chen, Jin-Yang
    Huang, Di-Hui
    Wang, Yan-Jun
    Chen, Sheng
    BIOSENSORS-BASEL, 2022, 12 (06):
  • [25] Electrochemical sensor for nitrite using a glassy carbon electrode modified with gold-copper nanochain networks
    Su-Su Huang
    Li Liu
    Li-Ping Mei
    Jia-Ying Zhou
    Fei-Ying Guo
    Ai-Jun Wang
    Jiu-Ju Feng
    Microchimica Acta, 2016, 183 : 791 - 797
  • [26] Electrochemical sensor for nitrite using a glassy carbon electrode modified with gold-copper nanochain networks
    Huang, Su-Su
    Liu, Li
    Mei, Li-Ping
    Zhou, Jia-Ying
    Guo, Fei-Ying
    Wang, Ai-Jun
    Feng, Jiu-Ju
    MICROCHIMICA ACTA, 2016, 183 (02) : 791 - 797
  • [27] Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat
    Tomkova, H.
    Sokolova, R.
    Opletal, T.
    Kucerova, P.
    Kucera, L.
    Souckova, J.
    Skopalova, J.
    Bartak, P.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 821 : 33 - 39
  • [28] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Hong Yu Huo
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2009, 167 : 195 - 199
  • [29] Electrochemical oxidation behavior of 8-azaguanine at graphene-Nafion composite film-modified glassy carbon electrode
    Yanju Wu
    Shengguo Zhai
    Kui Lu
    Lin Gao
    Journal of Solid State Electrochemistry, 2014, 18 : 1593 - 1600
  • [30] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Huo, Hong Yu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2009, 167 (3-4) : 195 - 199