ELECTRODE POTENTIAL MEASUREMENTS OF CONCRETE REINFORCEMENT FOR CORROSION EVALUATION

被引:16
|
作者
FRANCOIS, R
ARLIGUIE, G
BARDY, D
机构
[1] Lab. Materiaux et Durabilite des Constructions I.N.S.A. - U.P.S. Complexe scientifique de Rangueil
关键词
D O I
10.1016/0008-8846(94)90127-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This article deals with the correlation between active corrosion of steel in concrete and electrode potential measurements obtained by both classical method and bi-electrode method. In a first part, this paper deals with a relative value interpretation method which leaves aside the degree of ambiant hygrometry and the moisture of concrete. This relative value interpretation exhibits a good correlation between the corroded areas of concrete reinforcing rebars extracted from laboratory beams and the potential measurement. In a second part, this paper deals with an improved potential measurement using two reference electrodes. Two kinds ot bi-electrode device are presented. In the first place, one reference electrode is fixed and takes the place of the electrical connection to reinforcement. Secondly, the two reference electrodes are moving simultaneously. With the relative value method, it is possible to make direct use of the values measured with both types of bi-electrode device. The results presented show a good correlation between potential measurement obtained by bi-electrode devices and corrosion of rebars.
引用
收藏
页码:401 / 412
页数:12
相关论文
共 50 条