An Anthropometric and Three-Dimensional Computed Tomographic Evaluation of Two-Point Fixation of Zygomatic Complex Fractures

被引:10
|
作者
Jo, Taehee [1 ]
Kim, Junhyung [1 ]
机构
[1] Keimyung Univ, Dongsan Med Ctr, Dept Plast & Reconstruct Surg, Daegu, South Korea
来源
ARCHIVES OF PLASTIC SURGERY-APS | 2014年 / 41卷 / 05期
关键词
Zygomatic fractures; Fracture fixation; Anthropometry;
D O I
10.5999/aps.2014.41.5.493
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Maintaining stability and restoring the aesthetic appearance are the fundamental goals when managing zygomatic fractures. We aimed to evaluate the stability and anthropometric outcomes of zygomatic fracture patients who underwent two-point fixation involving the infraorbital rim and zygomaticomaxillary buttress via the transconjunctival and gingivobuccal approaches without any skin incisions. Methods We examined 15 zygomatic fracture patients who underwent two-point fixation during a 3-year period. Stability was evaluated using three-dimensional facial bone computed tomography. Superoinferior and anteroposterior displacement of the zygoma was quantified. The aesthetic appearance of the periorbital region was evaluated using indirect anthropometry with standardized clinical photographs. The ratios between the eye fissure height and width, and lower iris coverage ratio were used to evaluate aesthetical changes. The bony displacement and aesthetic ratios were analyzed using Wilcoxon or Friedman tests. The correlation between the preoperative zygoma position and anthropometric values was analyzed. Results The positions of the zygoma were similar to those on the contralateral side at the long-term follow-up. The preoperative anthropometric measurements on the fractured side differed from those on the contralateral side, although these values were close to the normal values at the long-term follow-up. Furthermore, we noted that the anteroposterior displacement strongly positively correlated with the lower iris coverage rate (Spearman's coefficient = 0.678, P = 0.005). Conclusions Two-point fixation of zygomatic fractures achieved stable outcomes on long-term follow-up, and also appeared to be reliable in restoring the aesthetic appearance of the periorbital region.
引用
收藏
页码:493 / 499
页数:7
相关论文
共 50 条
  • [41] Three-Dimensional Segmentation of the Tumor in Computed Tomographic Images of Neuroblastoma
    Hanford J. Deglint
    Rangaraj M. Rangayyan
    Fábio J. Ayres
    Graham S. Boag
    Marcelo K. Zuffo
    Journal of Digital Imaging, 2007, 20 : 72 - 87
  • [42] Three-dimensional segmentation of the tumor in computed tomographic images of neuroblastoma
    Deglint, Hanford J.
    Rangayyan, Rangaraj M.
    Ayres, Fabio J.
    Boag, Graham S.
    Zuffo, Marcelo K.
    JOURNAL OF DIGITAL IMAGING, 2007, 20 (01) : 72 - 87
  • [43] Three-dimensional computed tomographic analysis of variations of the carotid artery
    Nagata, Tetsuji
    Masumoto, Kazuma
    Hayashi, Yutaro
    Watanabe, Yoshiko
    Kato, Yuta
    Katou, Fuminori
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (06) : 734 - 742
  • [44] Three-dimensional computed tomographic scan of the external third of the clavicle
    Nourissat, Geoffroy
    Henon, Agnes
    Debet-Mejean, Aurore
    Clement, Pradel
    Dumontier, Christian
    Sautet, Alain
    Doursounian, Levon
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (01): : 29 - 33
  • [45] Three-dimensional segmentation of the tumor in computed tomographic images of neuroblastoma
    Deglint, Hanford J.
    Rangayyan, Rangaraj M.
    Ayres, Fabio J.
    Boag, Graham S.
    Zuffo, Marcelo K.
    JOURNAL OF DIGITAL IMAGING, 2007, 20 (03) : 263 - 278
  • [46] Innovation in Three-Dimensional Echocardiography and Cardiac Computed Tomographic Angiography
    Hlavacek, Anthony M.
    Baker, G. Hamilton
    Shirali, Girish S.
    CARDIOLOGY IN THE YOUNG, 2009, 19 : 35 - 42
  • [47] Three-Dimensional Computed Tomographic Findings of Bilateral Tracheal Bronchus
    Watabnabe, Kazuhiro
    Uese, Keiichirou
    Higuchi, Osamu
    Futatani, Takeshi
    Yoshimura, Naoki
    Nakamura, Tsuneyuki
    Ichida, Fukiko
    PEDIATRIC CARDIOLOGY, 2009, 30 (01) : 87 - 88
  • [48] Three-dimensional computed tomographic angiography in lower extremity revascularization
    Ishikawa, M
    Morimoto, N
    Sasajima, T
    Kubo, Y
    SURGERY TODAY, 1999, 29 (03) : 243 - 247
  • [49] Three-dimensional computed tomographic angiography in lower extremity revascularization
    Ishikawa M.
    Morimoto N.
    Sasajima T.
    Kubo Y.
    Surgery Today, 1999, 29 (3) : 243 - 247
  • [50] Three-dimensional helical computed tomographic angiography in neonates and infants with complex congenital heart disease
    Kawano, T
    Ishii, M
    Takagi, J
    Maeno, Y
    Eto, G
    Sugahara, Y
    Toshima, T
    Yasunaga, H
    Kawara, T
    Todo, K
    Kato, H
    AMERICAN HEART JOURNAL, 2000, 139 (04) : 654 - 660