Experience Of One-Electrode Symplicity Flex Catheter And Multi-Electrode Symplicity Spyral Catheter In Kazakhstan

被引:0
|
作者
Azretovich, Yernazarov Adilet [1 ]
Dzhoshibaev, Seithan [2 ]
Baymagambetov, Amirhan Kemelkulovitch [3 ]
Vadim, Seisembekov [4 ]
Timur, Seisembekov [4 ]
Almas, Begdildaev [4 ]
机构
[1] A Yasavi Int Kazakh Turkish Univ, Abay St 38A, Shardara City 161400, South Kazakhsta, Kazakhstan
[2] Sci Clin Ctr Cardiac Surg & Transplantat, Abai Ave 196-1, Taraz 080000, Kazakhstan
[3] A Yasavi Int Kazakh Turkish Univ, Baityrsynov St 7, Shymkent 160000, Kazakhstan
[4] Sci Clin Ctr Cardiac Surg & Transplantat, Abai Ave 196-1, Taraz 080000, Kazakhstan
关键词
resistant arterial hypertension; renal artery radiafrequency denervation; multi-electrode catheter;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of research is to compare the efficacy and safety of applying one-electrode Symplicity Flex catheter and multi-electrode Symplicity Spyral catheter. Materials and methods. Inclusion criteria: age 3070, diagnosed with essential arterial hypertension (AH), arterial pressure (AP) > 60/100 mm Hg. resulted while taking three or more drugs with written informed consent. Exclusion criteria: average daily systolic AP <135 mm Hg., glomerular filtration rate < 45 ml/min/1.73 m2), symptomatic AH. In both groups there was Performed renal artery radiofrequency denervation (RDN) with radiofrequency power 5-8 watt with constantly controlled temperature and impedance. In the I-st group, the duration of each application was 2 minutes, in the II-nd group duration of each application made up 1 min. Results. At he time of this analysis the renal artery radiofrequency denervation was performed with 44 patients in the I-st group and 14 patients in the II-nd group. 6 months later after renal artery RDN 25 patients of the I-st group and 4 of them in the II-nd group were examined once more. In no case there were revealed long-term complications, significant deterioration of renal blood flow and renal function. It was found a marked reduction of office AP 6 months later after the application of renal artery RDN, there was a decrease of systolic AP/diastolic AP indexes at the office measurement for 39/28 mm Hg. (p <0,01) in the I-group and for 58/46 mm Hg. in the II-group, respectively. The average duration of renal artery RDN procedure in the I-group was 63 3 +/- 27,01 min., 01 min while in the II-group -36,4 +/- 15,63 min. Conclusion. Application of multi-electrode catheter in Clinical practice helps to significantly reduce the total duration of intervention and improve efficiency.
引用
收藏
页码:2698 / 2704
页数:7
相关论文
共 50 条
  • [41] First Human Assessment of a Multi-Electrode RF Balloon Catheter System to Treat Symptomatic Paroxysmal Atrial Fibrillation
    Al-Ahmad, Amin
    Melton, Ian
    Daly, Matt
    Natale, Andrea
    Badhwar, Nitish
    Lee, Byron K.
    Lee, Randall
    Crozier, Ian
    CIRCULATION, 2016, 134
  • [42] The Use of the Multi-Electrode Duty-Cycled Radiofrequency Ablation Catheter PVAC for the Ablation of a Left Atrial Tachycardia
    Leftheriotis, Dionyssios
    Flevari, Panayota
    Simeonidou, Eftihia
    Niokou, Dimitra
    Anastasiou-Nana, Maria
    HELLENIC JOURNAL OF CARDIOLOGY, 2012, 53 (02) : 163 - 167
  • [43] CLINICAL EXPERIENCE WITH NEW TRANSVENOUS CATHETER ELECTRODE MIP 2000
    SCHMITT, G
    VONMALOT.H
    WINTER, R
    BRAUN, L
    HAUSS, WH
    CLINICA TERAPEUTICA, 1974, 68 (06): : 511 - 518
  • [44] CLINICAL EXPERIENCE WITH AN IMPLANTED PACEMAKER-CATHETER ELECTRODE SYSTEM
    CHARDACK, WM
    FEDERICO, AJ
    GAGE, AA
    GREATBAT.W
    CIRCULATION, 1965, 32 (4S2) : 67 - &
  • [45] First reported cases: renal denervation with second-generation multi-electrode catheter via brachial and radial access
    Heradien, M. J.
    Augustyn, J.
    Saaiman, A.
    Brink, P. A.
    CARDIOVASCULAR JOURNAL OF AFRICA, 2016, 27 (01) : 53 - 55
  • [46] Atrial Fibrillation Ablation with a Novel Fully 3D-Mapping-Integrated Multi-Electrode Radiofrequency Balloon Catheter
    Teumer, Yannick
    Miesbichler, Clemens
    Hauke, Andreas
    Katov, Lyuboslav
    Bothner, Carlo
    Pott, Alexander
    Mueller, Martin
    Walter, Benjamin
    Rottbauer, Wolfgang
    Dahme, Tillman
    Weinmann, Karolina
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)
  • [47] Effective ablation settings that predict chronic scar after atrial ablation with HELIOSTAR™ multi-electrode radiofrequency balloon catheter
    Ishidoya, Yuki
    Kwan, Eugene
    Hunt, Bram
    Lange, Matthias
    Sharma, Tushar
    Dosdall, Derek J.
    Macleod, Rob S.
    Kholmovski, Eugene G.
    Bunch, T. Jared
    Ranjan, Ravi
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024,
  • [48] Duty Cycled, Unipolar-Bipolar RF Ablation via Multi-Electrode Catheter in Patients With Paroxysmal Atrial Fibrillation
    Kongstad, Ole
    Yuan, Shiwen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A111 - A111
  • [49] Multi-electrode tunable liquid crystal lenses with one lithography step
    Beeckman, Jeroen
    Yang, Tzu-Hsuan
    Nys, Inge
    George, John Puthenparampil
    Lin, Tsung-Hsien
    Neyts, Kristiaan
    OPTICS LETTERS, 2018, 43 (02) : 271 - 274
  • [50] ELECTRODE CATHETER ABLATION OF REFRACTORY VENTRICULAR-TACHYCARDIA - CONTINUED EXPERIENCE
    HARTZLER, GO
    GIORGI, LV
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 512 - 512