Experience Of One-Electrode Symplicity Flex Catheter And Multi-Electrode Symplicity Spyral Catheter In Kazakhstan

被引:0
|
作者
Azretovich, Yernazarov Adilet [1 ]
Dzhoshibaev, Seithan [2 ]
Baymagambetov, Amirhan Kemelkulovitch [3 ]
Vadim, Seisembekov [4 ]
Timur, Seisembekov [4 ]
Almas, Begdildaev [4 ]
机构
[1] A Yasavi Int Kazakh Turkish Univ, Abay St 38A, Shardara City 161400, South Kazakhsta, Kazakhstan
[2] Sci Clin Ctr Cardiac Surg & Transplantat, Abai Ave 196-1, Taraz 080000, Kazakhstan
[3] A Yasavi Int Kazakh Turkish Univ, Baityrsynov St 7, Shymkent 160000, Kazakhstan
[4] Sci Clin Ctr Cardiac Surg & Transplantat, Abai Ave 196-1, Taraz 080000, Kazakhstan
关键词
resistant arterial hypertension; renal artery radiafrequency denervation; multi-electrode catheter;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of research is to compare the efficacy and safety of applying one-electrode Symplicity Flex catheter and multi-electrode Symplicity Spyral catheter. Materials and methods. Inclusion criteria: age 3070, diagnosed with essential arterial hypertension (AH), arterial pressure (AP) > 60/100 mm Hg. resulted while taking three or more drugs with written informed consent. Exclusion criteria: average daily systolic AP <135 mm Hg., glomerular filtration rate < 45 ml/min/1.73 m2), symptomatic AH. In both groups there was Performed renal artery radiofrequency denervation (RDN) with radiofrequency power 5-8 watt with constantly controlled temperature and impedance. In the I-st group, the duration of each application was 2 minutes, in the II-nd group duration of each application made up 1 min. Results. At he time of this analysis the renal artery radiofrequency denervation was performed with 44 patients in the I-st group and 14 patients in the II-nd group. 6 months later after renal artery RDN 25 patients of the I-st group and 4 of them in the II-nd group were examined once more. In no case there were revealed long-term complications, significant deterioration of renal blood flow and renal function. It was found a marked reduction of office AP 6 months later after the application of renal artery RDN, there was a decrease of systolic AP/diastolic AP indexes at the office measurement for 39/28 mm Hg. (p <0,01) in the I-group and for 58/46 mm Hg. in the II-group, respectively. The average duration of renal artery RDN procedure in the I-group was 63 3 +/- 27,01 min., 01 min while in the II-group -36,4 +/- 15,63 min. Conclusion. Application of multi-electrode catheter in Clinical practice helps to significantly reduce the total duration of intervention and improve efficiency.
引用
收藏
页码:2698 / 2704
页数:7
相关论文
共 50 条
  • [1] Comparison of Symplicity Flex™, Multi-Electrode Prototype and the Symplicity Spyral™ Renal Denervation Catheters in a Porcine Model
    Tunev, Stefan
    Melder, Robert J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B245 - B245
  • [2] Renal Denervation With Symplicity Spyral Catheter in the Global Symplicity Registry: Safety and Efficacy at 3 Years
    Boehm, Michael
    Mahfoud, Felix
    Williams, Bryan
    Ruilope, Luis
    Narkiewicz, Krzysztof
    Schlaich, Markus
    Fahy, Martin
    Mancia, Giuseppe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B84 - B84
  • [3] Long-Term Safety and Efficacy of Renal Denervation with the Symplicity Spyral Catheter in the Global SYMPLICITY Registry
    Schlaich, Markus P.
    Mahfoud, Felix
    Williams, Bryan
    Ruilope, Luis M.
    Narkiewicz, Krzysztof
    Fahy, Martin
    Mancia, Giuseppe
    Bohm, Michael
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 560 - 560
  • [4] Long-Term Safety and Efficacy of Renal Denervation in the Global Symplicity Registry Using the Symplicity Spyral Catheter
    Wang, Tzung-Dau
    Schlaich, Markus
    Mahfoud, Felix
    Wiliams, Bryan
    Ruilope, Luis
    Narkiewicz, Krzystzof
    Fahy, Martin
    Mancia, Giuseppe
    Boehm, Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (16) : S2 - S2
  • [5] Symplicity multi-electrode radiofrequency renal deneivation system feasibility study
    Whitbourn, Robert
    Harding, Scott A.
    Walton, Antony
    EUROINTERVENTION, 2015, 11 (01) : 104 - 109
  • [6] Rescue trans-radial renal denervation with the new Symplicity Spyral™ catheter
    Greco, F.
    Spagnolo, V.
    Fascetti, F.
    MINERVA CARDIOANGIOLOGICA, 2015, 63 (06): : 587 - 588
  • [7] Renal denervation treatment with the Symplicity Spyral multielectrode catheter: 6-month safety and blood pressure outcomes from the Global SYMPLICITY Registry
    Boehm, Michael
    Brilakis, Nicole
    Mancia, Giuseppe
    Narkiewicz, Krzysztof
    Ruilope, Luis
    Schlaich, Markus
    Mahfoud, Felix
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B308 - B308
  • [8] POOLED, 6-MONTH SAFETY AND EFFICACY RESULTS USING THE SYMPLICITY SPYRAL RADIOFREQUENCY RENAL DENERVATION CATHETER
    Mahfoud, Felix
    Mancia, Giuseppe
    Townsend, Raymond
    Kandzari, David
    Whitbourn, Robert
    Boehm, Michael
    JOURNAL OF HYPERTENSION, 2023, 41 : E51 - E51
  • [9] Pooled, 12-Month Blood Pressure Reductions Using the Symplicity Spyral Radiofrequency Renal Denervation Catheter
    Mahfoud, Felix
    Mancia, Giuseppe
    Kandzari, David
    Whitbourn, Robert
    Boehm, Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B105 - B105
  • [10] Renal ablation for treatment of hypertension without Symplicity catheter: The first human experience
    Honarvar, Mehrdad
    Amirpour, Afshin
    Pourmoghaddas, Masoud
    ARYA ATHEROSCLEROSIS, 2013, 9 (01) : 82 - 88