ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF GINSENOSIDES

被引:66
|
作者
VANBREEMEN, RB
HUANG, CR
LU, ZZ
RIMANDO, A
FONG, HHS
FITZLOFF, JF
机构
[1] Department of Medicinal Chemistry and Pharmacognosy, University of Illinois at Chicago (m/c 781), Illinois, 833 South Wood Street, Chicago
[2] USDA, Richard B. Russell Agriculture Research Center, Athens
关键词
D O I
10.1021/ac00117a026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrospray liquid chromatography/mass spectrometry (LC/MS) method has been developed for the analysis of ginseng saponins (ginsenosides) contained in extracts of the root of Panax ginseng (Korean ginseng) and Panax quinquefolius (American ginseng), The LC/MS method consists of separation of ginsenosides using an (aminopropyl)silica HPLC column, followed by detection using a photodiode array UV absorbance detector and then on-line electrospray mass spectrometry. Ginsenosides eluted from the HPLC column in order of increasing molecular weight and were detected as [M + Na](+) or [RI + 138](+) adducts, Occurrence of [M + 138](+) adducts was most prominent when new HPLC columns were used, and none were observed when solutions of ginsenoside standards were infused into the mass spectrometer without use of HPLC, The cation weighing 138 was identified as (3-ammoniumpropyl)trihydroxysilane, (NH4)-N-+(CH2)(3)Si(OH)(3), which was either a byproduct of stationary phase synthesis or a stationary phase degradation product. LC/MS chromatograms of extracts of Korean ginseng and American ginseng demonstrated substantial differences between the relative amounts of each ginsenoside, Based on molecular weight and coelution with standards, ginsenosides R(g1), R(e), R(d), R(c), R(b2), and R(b1) (in order of elution from the HPLC column) were identified in both ginseng extracts. Four other ginsenosides were detected by mass spectrometry for which no standards were available, and their molecular weights were 801 (possibly corresponding to ginsenoside R(f)), 817, 947, and 963 (possibly 20-gluco-R(f)), The ginsenosides weighing 817 and 963 were detected only in the Korean ginseng extract.
引用
收藏
页码:3985 / 3989
页数:5
相关论文
共 50 条
  • [31] DETERMINATION OF NONIONIC POLYETHOXYLATE SURFACTANTS IN ENVIRONMENTAL WATERS BY LIQUID-CHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY
    CRESCENZI, C
    DICORCIA, A
    SAMPERI, R
    MARCOMINI, A
    ANALYTICAL CHEMISTRY, 1995, 67 (11) : 1797 - 1804
  • [32] LIQUID-CHROMATOGRAPHY AND MASS-SPECTROMETRY - DIFFICULT MARRIAGE
    ARPINO, P
    RECHERCHE, 1975, 6 (59): : 769 - 772
  • [33] AUTOMATED LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY FOR CHROMATOGRAPHERS
    PULLEN, FS
    RICHARDS, DS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (02) : 188 - 190
  • [34] LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF ANTISENSE OLIGONUCLEOTIDES
    BOTHNER, B
    CHATMAN, K
    SARKISIAN, M
    SIUZDAK, G
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 1995, 5 (23) : 2863 - 2868
  • [35] A BIBLIOGRAPHY OF COMBINED LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    EDMONDS, CG
    MCCLOSKEY, JA
    EDMONDS, VA
    BIOMEDICAL MASS SPECTROMETRY, 1983, 10 (04): : 237 - 252
  • [36] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF CORTICOSTEROIDS
    STEFFENRUD, S
    MAYLIN, G
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02): : 221 - 227
  • [37] APPLICATIONS OF THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    BACZYNSKYJ, L
    BRONSON, GE
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12): : 253 - 254
  • [38] A REVIEW OF COMBINED LIQUID-CHROMATOGRAPHY AND MASS-SPECTROMETRY
    DESIDERIO, DM
    FRIDLAND, GH
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 : 317 - 351
  • [39] THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    BLAKLEY, CR
    VESTAL, ML
    ANALYTICAL CHEMISTRY, 1983, 55 (04) : 750 - 754
  • [40] REVIEW OF THE DEVELOPMENT OF LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    CAIRNS, T
    SIEGMUND, EG
    ACS SYMPOSIUM SERIES, 1990, 420 : 1 - 11