AN EVALUATION OF 2 ACTIVATED CLOTTING TIME MONITORS DURING CARDIAC-SURGERY

被引:10
|
作者
REICH, DL
ZAHL, K
PERUCHO, MH
THYS, DM
机构
[1] From the Department of Anesthesiology, Mount Sinai Medical Center, New York, 10029-6574, NY, One Gustave L. Levy Place
来源
JOURNAL OF CLINICAL MONITORING | 1992年 / 8卷 / 01期
关键词
BLOOD; COAGULATION; HEPARIN;
D O I
10.1007/BF01618085
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The activated clotting time (ACT) is a commonly used method for assessing the degree of anticoagulation during cardiac surgery. Two automated ACT monitors were evaluated in 29 adult patients undergoing cardiac surgery. The HemoTec ACT monitor (HTC; HemoTec, Inc., Englewood, CO) was evaluated using 0.8 ml of whole blood in dual-chamber, high range kaolin cartridges. The Hemochron ACT monitor (HCH; International Technidyne, Inc, Edison, NJ) was evaluated using 2.0 ml of whole blood in glass tubes with diatomaceous earth activator. Following sternotomy, a coagulation profile consisting of HTC, HCH, and a partial thromboplastin time (PTT) was obtained (TO). Beef lung heparin was administered in 3 consecutive doses: 40 units/kg (T1, 80 units/kg (T2), and 180 units/kg (T3). Coagulation profiles were drawn 5 minutes after each dose. Following cardiopulmonary bypass (CPB), coagulation profiles were drawn 15 minutes (T4), 2 hours (T5), and 24 hours (T6) after the protamine dose. HTC and HCH ACT values differed significantly at T1, T2, and T4 (p < 0.001). In the pre-CPB period, the HCH ACT correlation with PTT divided by its control value (PTT/CTL) (r = 0.73) was significantly better (p = 0.02) than the correlation of HTC ACT with PTT/CTL (r = 0.41). In the post-CPB period, both HCH ACT (r = 0.45) and HTC ACT (r = 0.30) correlated weakly with PTT/CTL. In the bias analysis, the limits of agreement (of all HCH and HTC ACT values) showed that HTC ACT is between 61% and 133% of the HCH ACT value in 95% of determinations. These data contradict the results of a previous comparison of the two monitors, a study that suggested that HTC ACT overestimated anticoagulation at low heparin doses. HCH ACT correlated better than HTC ACT with the PTT values only in the pre-CPB period. The bias analysis indicates that even though the mean ACT values are usually close, there is considerable spread (-39 to +33%) when the 95% confidence intervals are calculated.
引用
收藏
页码:33 / 36
页数:4
相关论文
共 50 条
  • [21] CLEARANCE OF GENTAMICIN DURING CARDIAC-SURGERY
    HEYLEN, RM
    WILSON, APR
    HICHENS, M
    FELMINGHAM, D
    WEBB, A
    PATTISON, CW
    PUGSLEY, W
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1995, 35 (05) : 649 - 655
  • [22] CEREBRAL PERFUSION DURING CARDIAC-SURGERY
    LUNDAR, T
    LANCET, 1986, 2 (8504): : 457 - 457
  • [23] SCIATIC MONONEUROPATHY DURING CARDIAC-SURGERY
    MCMANIS, PG
    NEUROLOGY, 1993, 43 (04) : A215 - A215
  • [24] PROPRANOLOL LEVELS DURING CARDIAC-SURGERY
    BENNETT, MJ
    MANGANO, DT
    CRONNELLY, R
    WILKINSON, PL
    TEXEIRA, R
    ANESTHESIA AND ANALGESIA, 1981, 60 (04): : 239 - 240
  • [25] PROTECTION OF THE MYOCARDIUM DURING CARDIAC-SURGERY
    SEIFERT, PC
    HEART & LUNG, 1983, 12 (02): : 135 - 142
  • [26] HEART AND DRUGS DURING CARDIAC-SURGERY
    OKA, Y
    COEUR, 1984, 15 (03): : 289 - 293
  • [27] PHARMACOKINETICS OF AMRINONE DURING CARDIAC-SURGERY
    BAILEY, JM
    LEVY, JH
    ROGERS, HG
    SZLAM, F
    HUG, CC
    ANESTHESIOLOGY, 1991, 75 (06) : 961 - 968
  • [28] ELECTROENCEPHALOGRAPHIC MONITORING DURING CARDIAC-SURGERY
    EDMONDS, HL
    SLATER, AD
    SHIELDS, CB
    ANESTHESIOLOGY, 1993, 78 (01) : 208 - 208
  • [29] MYOCARDIAL PROTECTION DURING CARDIAC-SURGERY
    STEMMER, EA
    STANTON, WW
    CONNOLLY, JE
    CIRCULATION, 1972, 46 (04) : 226 - &
  • [30] The relationship between heparin level and activated clotting time in the adult cardiac surgery population
    FitzGerald, D. J.
    Patel, A.
    Body, S. C.
    Garvin, S.
    PERFUSION-UK, 2009, 24 (02): : 93 - 96