EXPIRATORY CAPNOGRAPHY IN ASTHMA - EVALUATION OF VARIOUS SHAPE INDEXES

被引:101
|
作者
YOU, B
PESLIN, R
DUVIVIER, C
VU, VD
GRILLIAT, JP
机构
[1] HOP CENT,SERV MED H,UMG,NANCY,FRANCE
[2] INSERM,U14,NANCY,FRANCE
关键词
ASTHMA; CAPNOGRAPHY; CARBON DIOXIDE; LUNG FUNCTION TESTS; MONITORING; SLEEP;
D O I
10.1183/09031936.94.07020318
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The shape of the capnogram is modified by airway obstruction, and the evaluation of this deformation, using measurable indices, could allow an indirect measurement of bronchial patency. A previous study undertaken in asthmatic subjects showed a good correlation between a capnographic index (end-tidal slope) and a spirometric parameter (forced expiratory volume in one second as a percentage of predicted (FEV(1) %pred)) and suggested the study of other indices. The correlations between capnographic and spirometric indices were measured in 10 healthy subjects and 30 asthmatic patients. The usefulness of eight descriptive indices, analysing the successive phases of the capnogram, was assessed by measuring their reproducibility and their sensitivity to airway obstruction. The intraindividual and interindividual variabilities (Vi and VI) and the noise/signal ratio (Vi/VI) were measured by comparing the results of two successive capnographic measurements in 14 asthmatic subjects. The results show an increasing noise/signal ratio along the expiration (between 23 and 62%). Significant correlations between spirometry and capnography were found with all indices, but the strongest were observed with indices analysing the intermediate phase of the capnogram, that is the angle between the ascending phase (E2) and the alveolar plateau (E3). The correlations show that the analysis of the capnogram's shape is a quantitative method for evaluating the severity of bronchospasm. This ability, added to specific advantages (noninvasiveness, effort-independency, measurements during tidal breathing) opens new fields of application to capnography, such as measurement of bronchospasm in children and computerized monitoring of asthma.
引用
收藏
页码:318 / 323
页数:6
相关论文
共 50 条
  • [21] Bacterial shape maintenance: an evaluation of various models
    Grover, NB
    Eidelstein, E
    Koppes, LJH
    JOURNAL OF THEORETICAL BIOLOGY, 2004, 227 (04) : 547 - 559
  • [22] A COMMENT ON SHAPE INDEXES
    DANTA, DR
    PROFESSIONAL GEOGRAPHER, 1987, 39 (02): : 199 - 200
  • [23] The expiratory nature of stridor in bronchial asthma
    Grant, D
    LANCET, 1910, 1 : 1499 - 1499
  • [24] PHARMACOLOGICAL EVALUATION OF VARIOUS ANTI-ASTHMA DRUGS
    HVIDBERG, E
    ACTA ALLERGOLOGICA, 1971, 26 : 54 - 82
  • [25] Evaluation of Asthma Control using Patient Based Measures and Peak Expiratory Flow Rate
    Pereira, L. M. Pinto
    Boodoo, S.
    Dindial, K. A.
    Hosein, A.
    Seemungal, T. A. R.
    Bekele, I.
    WEST INDIAN MEDICAL JOURNAL, 2009, 58 (03): : 214 - 218
  • [26] Volumetric capnography in the assessment of distal airway function in patients with asthma
    Ponomareva, Irina
    Abrosimov, Vladimir
    Subbotin, Sergey
    Byalovskiy, Yuriy
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [27] CELLULAR INDEXES OF THE SERIOUSNESS OF ASTHMA
    TONNEL, AB
    MARQUETTE, CH
    REVUE FRANCAISE D ALLERGOLOGIE ET D IMMUNOLOGIE CLINIQUE, 1991, 31 (02): : 101 - 104
  • [28] Evaluation of Transducers through Mainstream Capnography
    Portela, A. E.
    Milanes, A.
    Folgueras, J.
    Rodriguez, A.
    Cartaya, M.
    de Nacimiento, D.
    Gomez, M.
    Garcia, M. A.
    Rodriguez, J. A.
    Aguilera, A.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 826 - 829
  • [29] Detecting Growth Shape Misspecifications in Latent Growth Models: An Evaluation of Fit Indexes
    Leite, Walter L.
    Stapleton, Laura M.
    JOURNAL OF EXPERIMENTAL EDUCATION, 2011, 79 (04): : 361 - 381
  • [30] Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
    Restrepo, Ruben D.
    Karpenkop, Ido
    Liu, Katherine E.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (163): : 1 - 18