ON SOME FACTORS AFFECTING DISCHARGE CONDITIONS IN MICRO-STRIP GAS-CHAMBERS

被引:22
|
作者
BOUCLIER, R
CAPEANS, M
GARABATOS, C
MANZIN, G
MILLION, G
ROPELEWSKI, L
SAULI, F
TEMMEL, T
SHEKHTMAN, L
NAGASLAEV, V
PESTOV, Y
KULESHOV, A
机构
[1] CERN,CH-1211 GENEVA,SWITZERLAND
[2] NOVOSIBIRSK NUCL PHYS INST,NOVOSIBIRSK 630090,RUSSIA
[3] MOSCOW MV LOMONOSOV STATE UNIV,MOSCOW 119899,RUSSIA
关键词
D O I
10.1016/0168-9002(95)00453-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the results of an investigation on the influence of geometrical parameters on the maximum gain that can be attained in a micro-strip gas chamber. Single electron emission from the cathode was confirmed to be a precursor of discharge, particularly for gas mixtures with a high fraction of quencher, confirming our previous observations. In contradiction however with the results of a theoretical model proposed in earlier work, we found that the maximum gain is obtained in a narrow range of cathode strip width. This suggests the presence of other mechanisms initiating a discharge, such as photon- or ion-initiated feedback. The influence of strongly ionising irradiation on discharge conditions has also been investigated; we have observed an increasing probability of discharge in detectors irradiated with a particles, releasing around 1 MeV in the gas, as compared to 6 keV X-rays. This results in a reduction by a factor of 2 of the maximum gain at which a MSGC can be safely operated, a concern for the use of micro-strip chambers in vertex detectors for colliders where low energy, heavily ionizing particles and thermal neutrons are produced together with minimum ionizing particles.
引用
收藏
页码:65 / 69
页数:5
相关论文
共 50 条
  • [41] Energy resolution and counting properties of micro-strip gas counter for X-ray detecting
    Su, QF
    Xia, YB
    Wang, LJ
    Yang, Y
    Shi, WM
    MODERN PHYSICS LETTERS A, 2005, 20 (29) : 2253 - 2259
  • [42] A LOW-PRESSURE, MICRO-STRIP GAS CHAMBER OPERATED WITH SECONDARY-ELECTRON EMISSION
    ANDERSON, DF
    KWAN, S
    SALOMON, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2): : 102 - 106
  • [43] Optimization of a micro-strip gas chamber as a two-dimensional neutron detector using gadolinium converter
    Masaoka, S
    Nakamura, T
    Yamagishi, H
    Soyama, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03): : 538 - 549
  • [44] Development of two-dimensional micro-strip gas detector with individual readouts for neutron scattering experiments
    Tanaka, H.
    Nakamura, T.
    Yamagishi, H.
    Soyama, K.
    Aizawa, K.
    Ochi, A.
    Tanimori, T.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) : 2264 - 2269
  • [45] Development of a transparent single-grid-type micro-strip gas chamber based on LCD technology
    Lian, Xuan
    Takahashi, Hiroyuki
    Miyoshi, Hiroaki
    Mitsuya, Yuki
    Shimazoe, Kenji
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2018, 55 (07) : 805 - 811
  • [46] Some conditions affecting the discharge of food from the stomach
    Hedblom, CA
    Cannon, WB
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1909, 138 : 504 - 521
  • [47] Micro strip gas chambers overcoated with carbon, hydrogenated amorphous silicon, and glass films
    Bishai, MR
    Gerndt, EKE
    Shipsey, IPJ
    Bagulya, AV
    Grishin, VM
    Negodaev, MA
    Ligachev, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 400 (2-3): : 233 - 242
  • [48] Energy resolution in X-ray detecting micro-strip gas chamber fabricated on CVD diamond films
    Zhang, ML
    Xia, YB
    Wang, LJ
    Yin, Y
    Lin, W
    Gu, BB
    FIFTH INTERNATIONAL CONFERENCE ON THIN FILM PHYSICS AND APPLICATIONS, 2004, 5774 : 91 - 94
  • [49] TEST BEAM RESULTS OF A LOW-PRESSURE MICRO-STRIP GAS CHAMBER WITH A SECONDARY-ELECTRON EMITTER
    KWAN, S
    ANDERSON, DF
    ZIMMERMAN, J
    SBARRA, C
    SALOMON, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 419 - 422
  • [50] Test beam results of a low-pressure micro-strip gas chamber with a secondary-electron emitter
    Kwan, S.
    Anderson, D.F.
    Zimmerman, J.
    Sbarra, C.
    Salomon, M.
    IEEE Transactions on Nuclear Science, 1995, 42 (4 pt 1): : 419 - 422