QUANTIFICATION OF THE DEGRADATION PRODUCTS OF SEVOFLURANE IN 2 CO2 ABSORBANTS DURING LOW-FLOW ANESTHESIA IN SURGICAL PATIENTS

被引:152
|
作者
FRINK, EJ
MALAN, TP
MORGAN, SE
BROWN, EA
MALCOMSON, M
BROWN, BR
机构
[1] Department of Anesthesiology, Univ. of Arizona Health Sci. Center, Tucson
关键词
ANESTHETICS; VOLATILE; SEVOFLURANE; EQUIPMENT; CO2; ABSORBERS; TOXICITY; HEPATIC; RENAL;
D O I
10.1097/00000542-199212000-00003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Sevoflurane, a new inhalational anesthetic agent has been shown to produce degradation products upon interaction with CO2 absorbants. Quantification of these sevoflurane degradation products during low-flow or closed circuit anesthesia in patients has not been well evaluated. The production of sevoflurane degradation products was evaluated using a low-flow anesthetic technique in patients receiving sevoflurane anesthesia in excess of 3 h. Sevoflurane anesthesia was administered to 16 patients using a circle absorption system with O2 flow of 500 ml/min and average N2O flow of 273 ml/min. Preoperative and postoperative hepatic and renal function studies were performed. Gas samples were obtained from the inhalation and exhalation limbs of the anesthetic circuit for degradation product analysis and analyzed by gas chromatography/mass spectrometry for four degradation products. The first eight patients received sevoflurane anesthesia using soda lime, and the following eight patients received anesthesia using baralyme as the CO2 absorbant. CO2 absorbant temperatures were measured during anesthesia. Of the degradation products analyzed, only one compound [fluoromethyl-2, 2-difluoro-1-(trifluoromethyl) vinyl ether], designated compound A, was detectable. Concentrations of compound A increased during the first 4 h of anesthesia with soda lime and baralyme and declined between 4 and 5 h when baralyme was used. Mean maximum inhalation concentration of compound A using baralyme was 20.28 +/- 8.6 ppm (mean +/- SEM) compared to 8.16 +/- 2.67 ppm obtained with soda lime, a difference that did not reach statistical significance. A single patient achieved a maximal concentration of 60.78 ppm during low-flow anesthesia with baralyme. Exhalation concentrations of compound A were less than inhalation concentrations, suggesting patient uptake. Peak CO2 absorbant temperatures were greater with baralyme (46.4 +/- 1.31-degrees-C) than soda lime (37.8 +/- 1.14-degrees-C) (P < .001). No abnormal changes in hepatic or renal function testing were detectable up to 48 h after anesthesia. Sevoflurane when used in a low-flow anesthetic circuit for 3-5 h duration generally produced low levels of a single degradation product, though in one case a higher concentration of compound A was produced. Although the concentrations of compound A obtained in this study are well below those reported to cause toxicity in animals, further studies will be needed to evaluate potential variability in compound A production. No patient in our study had clinical or laboratory evidence of organ toxicity following low-flow sevoflurane anesthesia.
引用
收藏
页码:1064 / 1069
页数:6
相关论文
共 50 条
  • [31] ROLE OF IMPAIRED CO2 REACTIVITY IN THE DIAGNOSIS OF CEREBRAL LOW-FLOW INFARCTS
    BAUMGARTNER, RW
    REGARD, M
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1994, 57 (07): : 814 - 817
  • [32] Role and potentials of low-flow CO2 removal system in mechanical ventilation
    Terragni, Pierpaolo
    Maiolo, Giorgia
    Ranieri, V. Marco
    CURRENT OPINION IN CRITICAL CARE, 2012, 18 (01) : 93 - 98
  • [33] Quantification of sevoflurane (compound A) degradation product using four brands of CO2 absorbent in vitro.
    Yasumi, Y
    Bito, H
    Sato, S
    ANESTHESIOLOGY, 1999, 91 (3A) : U231 - U231
  • [34] Compound A metabolism by renal B-lyase and detoxication to mercapturic acids during low-flow sevoflurane anesthesia
    Kharasch, ED
    Jubert, C
    ANESTHESIOLOGY, 1999, 91 (3A) : U232 - U232
  • [35] Cerebral autoregulation and CO2 reactivity in anterior and posterior cerebral circulation during sevoflurane anesthesia
    Rozet, I
    Vavilala, MS
    Lindley, AM
    Visco, E
    Treggiari, M
    Lam, AM
    ANESTHESIA AND ANALGESIA, 2006, 102 (02): : 560 - 564
  • [36] LOW-FLOW PRESSURE GRADIENT PUMPING FOR ACTIVE ABSORPTION OF CO2 ON A MOLECULAR SIEVE
    Cheng, Peng
    Wu, Shugang
    Fu, Yunchong
    Xiong, Xiaohu
    Niu, Zhenchuan
    Fan, Yukun
    RADIOCARBON, 2017, 59 (02) : 281 - 291
  • [37] Compound A concentrations during low-flow sevoflurane anesthesia correlate directly with the concentration of monovalent bases in carbon dioxide absorbents
    Higuchi, H
    Adachi, Y
    Arimura, S
    Kanno, M
    Satoh, T
    ANESTHESIA AND ANALGESIA, 2000, 91 (02): : 434 - 439
  • [38] The effect of light level, CO2 flow rate, and anesthesia on the stress response of mice during CO2 euthanasia
    Karin Powell
    Kelly Ethun
    Douglas K. Taylor
    Lab Animal, 2016, 45 : 386 - 395
  • [39] The effect of light level, CO2 flow rate, and anesthesia on the stress response of mice during CO2 euthanasia
    Powell, Karin
    Ethun, Kelly
    Taylor, Douglas K.
    LAB ANIMAL, 2016, 45 (10) : 386 - 395
  • [40] COMPARISON OF RENAL AND HEPATIC-FUNCTION IN SURGICAL PATIENTS ANESTHETIZED WITH SEVOFLURANE OR ISOFLURANE USING THE LOW-FLOW SYSTEM
    BITO, H
    IKEDA, K
    ANESTHESIOLOGY, 1995, 83 (3A) : A326 - A326