DOES CORRECTION OF STENOSES IDENTIFIED WITH COLOR DUPLEX SCANNING IMPROVE INFRAINGUINAL GRAFT PATENCY

被引:109
|
作者
MATTOS, MA [1 ]
VANBEMMELEN, PS [1 ]
HODGSON, KJ [1 ]
RAMSEY, DE [1 ]
BARKMEIER, LD [1 ]
SUMNER, DS [1 ]
PERLER, BA [1 ]
BERKOWITZ, H [1 ]
BANDYK, DF [1 ]
LEATHER, R [1 ]
机构
[1] SO ILLINOIS UNIV, SCH MED,DEPT SURG,PERIPHERAL VASC SURG SECT, POB 19230, SPRINGFIELD, IL 62794 USA
关键词
D O I
10.1016/0741-5214(93)90009-B
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: This study was undertaken (1) to determine whether correction of infrainguinal bypass stenoses detected with color duplex scanning (CDS) improved graft survival and (2) to define the natural history of grafts that did not undergo revision. Methods: Over a 39-month period 462 color-flow duplex scans were obtained on 170 limbs with autogenous vein grafts. Grafts were scanned within 3 months of operation, at 6 and 12 months, and then yearly. Doubling of the velocity at any point in the graft-arterial system compared with the velocity immediately above or below (velocity ratio greater-than-or-equal-to 2.0) was the criterion adopted for identification of a hemodynamically significant (greater-than-or-equal-to 50%) diameter reduction. Results: One hundred ten stenoses were detected in 62 (36%) of the limbs, of which 9 (8%) were in native vessels, 30 (27%) were at the anastomoses, and 71 (65%) were in the graft itself. Seventy-seven percent of the stenoses were detected in the first year. Twenty-four (39%) of the grafts with positive scans were revised. During follow-up, occlusions occurred in 10 (9%) of the 108 grafts with negative scans (NEG), in 2 (8%) of the 24 revised grafts with positive scans (PR), and in 10 (26%) of the 38 non-revised grafts with positive scans (PNR). Cumulative patency rates of NEG grafts were 90% at 1 year and 83% at 2 through 4 years. Similar patency rates were found in the PR vein grafts: 96% at 1 year and 88% at 2 through 4 years. In contrast, patency rates in PNR grafts with 50% or greater stenoses were only 66% at 1 year and 57% at 2 through 4 years. Log-rank tests showed a significant difference between the cumulative patency rates of NEG and PNR grafts (p < 0.002) and between PR and PNR grafts (p = 0.02). Flow velocities less than 45 cm/sec and ankle/brachial indexes did not discriminate well between grafts with or without 50% or greater stenoses or identify those grafts that subsequently occluded. Conclusions: The results of this study suggest that CDS detects graft-threatening lesions, that a velocity ratio of 2.0 or greater is the most highly predictive parameter, and that revision of grafts with stenoses identified with CDS prolongs patency.
引用
收藏
页码:54 / 66
页数:13
相关论文
共 23 条
  • [1] SURVEILLANCE OF INFRAINGUINAL ARTERIAL RECONSTRUCTIONS - DOES DUPLEX SCANNING IDENTIFY THE FAILING GRAFT
    WOLFLE, KD
    NEUDERT, S
    MAYER, B
    STORM, G
    BRUIJNEN, H
    LOEPRECHT, H
    ZENTRALBLATT FUR CHIRURGIE, 1992, 117 (10): : 540 - 546
  • [2] THE VALUE OF PREDISCHARGE DUPLEX SCANNING IN INFRAINGUINAL GRAFT SURVEILLANCE
    WILSON, YG
    DAVIES, AH
    CURRIE, IC
    MCGRATH, C
    MORGAN, M
    BAIRD, RN
    LAMONT, PM
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1995, 10 (02) : 237 - 242
  • [3] Intraoperative color duplex scanning for infrainguinal vein grafts
    Papanicolaou, G
    Aziz, I
    Yellin, AE
    Weaver, FA
    ANNALS OF VASCULAR SURGERY, 1996, 10 (04) : 347 - 355
  • [4] IMPACT OF A COLOR-FLOW DUPLEX SURVEILLANCE PROGRAM ON INFRAINGUINAL IN GRAFT PATENCY - A 5-YEAR EXPERIENCE
    IDU, MM
    BLANKENSTEIN, JD
    DEGIER, P
    TRUYEN, E
    BUTH, J
    BANDYK, DF
    JOURNAL OF VASCULAR SURGERY, 1993, 17 (01) : 42 - 53
  • [5] Predischarge duplex imaging of infrainguinal vein grafts does not predict the development of stenoses
    Olojugba, DH
    Varty, K
    Hartsthorne, T
    Naylor, AR
    Bell, PRF
    London, NJM
    BRITISH JOURNAL OF SURGERY, 1998, 85 (09) : 1225 - 1227
  • [6] DOES PHARMACOTHERAPY IMPROVE VEIN GRAFT PATENCY
    CHESEBRO, JH
    FUSTER, V
    JOURNAL OF CARDIOVASCULAR MEDICINE, 1984, 9 (05): : 409 - &
  • [7] Does dextran 40 improve the early patency of autogenous infrainguinal bypass grafts?
    Katz, SG
    Kohl, RD
    JOURNAL OF VASCULAR SURGERY, 1998, 28 (01) : 23 - 27
  • [8] INITIAL EXPERIENCE WITH COLOR-FLOW DUPLEX SCANNING OF INFRAINGUINAL BYPASS GRAFTS
    LONDREY, GL
    HODGSON, KJ
    SPADONE, DP
    RAMSEY, DE
    BARKMEIER, LD
    SUMNER, DS
    JOURNAL OF VASCULAR SURGERY, 1990, 12 (03) : 284 - 290
  • [9] Abnormal duplex findings at the proximal anastomosis of infrainguinal bypass grafts: Does revision enhance patency?
    Ryan, SV
    Dougherty, MJ
    Chang, M
    Lombardi, J
    Raviola, C
    Calligaro, K
    ANNALS OF VASCULAR SURGERY, 2001, 15 (01) : 98 - 103
  • [10] At what peak velocity ratio value should duplex-detected infrainguinal vein graft stenoses be revised?
    Olojugba, DH
    McCarthy, MJ
    Naylor, AR
    Bell, PRF
    London, NJM
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) : 258 - 260