Abnormal duplex findings at the proximal anastomosis of infrainguinal bypass grafts: Does revision enhance patency?

被引:5
|
作者
Ryan, SV [1 ]
Dougherty, MJ [1 ]
Chang, M [1 ]
Lombardi, J [1 ]
Raviola, C [1 ]
Calligaro, K [1 ]
机构
[1] Penn Hosp, Vasc Surg Sect, Philadelphia, PA 19106 USA
关键词
D O I
10.1007/BF02693808
中图分类号
R61 [外科手术学];
学科分类号
摘要
Using color duplex ultrasound (CDU) surveillance of autogenous infrainguinal bypasses, a peak systolic flow velocity (PSFV) ratio of greater than 3 to 1 within the graft relative to adjacent PSFV has been accepted as predicting significant stenosis mandating revision. At the proximal anastomosis, where significant vessel diameter differences and turbulent flow exist, the validity of these criteria is less clear. Our purpose was to review our experience with proximal anastomotic abnormalities in a CDU surveillance protocol. Routine CDU surveillance for all infrainguinal bypass gratis consisted of evaluation in an accredited vascular laboratory at 1 month postoperatively, every 3 months for the first year, every 6 months in the second year, and annually thereafter. Grafts with a PSFV ratio of >3 at the proximal anastomosis on any CDU study were included in this review. From our results we conclude that currently accepted CDU criteria for graft-threatening stenosis may not be valid for abnormalities at the proximal anastomosis of infrainguinal grafts. Regression of these abnormalities is common. Better CDU criteria are needed for predicting not only severity of proximal anastomotic stenosis but also likelihood of graft thrombosis.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 50 条
  • [1] Does gender influence the patency of infrainguinal bypass grafts?
    Alpagut, Ufuk
    Ugurlucan, Murat
    Banach, Maciej
    Mikhailidis, Dimitri P.
    Dayioglu, Enver
    ANGIOLOGY, 2008, 59 (03) : 278 - 282
  • [2] Does dextran 40 improve the early patency of autogenous infrainguinal bypass grafts?
    Katz, SG
    Kohl, RD
    JOURNAL OF VASCULAR SURGERY, 1998, 28 (01) : 23 - 27
  • [3] Patency after revision surgery for failing infrainguinal vein grafts
    Sato, O
    Miyata, T
    Deguchi, J
    Kimura, H
    Kondoh, K
    INTERNATIONAL ANGIOLOGY, 2000, 19 (03) : 255 - 258
  • [4] Outflow distribution at the distal anastomosis of infrainguinal bypass grafts
    Fisher, RK
    How, TV
    Bakran, A
    Brennan, JA
    Harris, PL
    JOURNAL OF BIOMECHANICS, 2004, 37 (03) : 417 - 420
  • [5] DUPLEX SCAN SURVEILLANCE OF INFRAINGUINAL PROSTHETIC BYPASS GRAFTS
    LALAK, NJ
    HANEL, KC
    HUNT, J
    MORGAN, A
    JOURNAL OF VASCULAR SURGERY, 1994, 20 (04) : 637 - 641
  • [6] DUPLEX SCAN SURVEILLANCE OF INFRAINGUINAL BYPASS GRAFTS - REPLY
    BOURKE, BM
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1993, 63 (01): : 80 - 81
  • [7] The effect of a surveillance programme on the patency of synthetic infrainguinal bypass grafts
    Dunlop, P
    Sayers, RD
    Naylor, AR
    Bell, PRF
    London, NJM
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 11 (04) : 441 - 445
  • [8] THE INFLUENCE OF GRAFT TYPE ON PATENCY OF INFRAINGUINAL ARTERIAL BYPASS GRAFTS
    NEALE, ML
    GRAHAM, JC
    LANE, RJ
    CHEUNG, DSM
    APPLEBERG, M
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1994, 178 (02) : 155 - 163
  • [9] Duplex guided balloon angioplasty of failing infrainguinal bypass grafts
    Marks, N. A.
    Hingorani, A. P.
    Ascher, E.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 32 (02) : 176 - 181
  • [10] DUPLEX SCAN SURVEILLANCE OF INFRAINGUINAL BYPASS GRAFTS - THE CASE FOR SELECTIVITY
    BOURKE, BM
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1992, 62 (08): : 611 - 617