CONTINUOUS MONITORING OF GLUCOSE WITH A TRANSCUTANEOUS MICRODIALYSIS PROBE

被引:0
|
作者
DEBOER, J
PLIJTERGROENDIJK, H
KORF, J
机构
来源
LANCET | 1992年 / 340卷 / 8818期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:547 / 548
页数:2
相关论文
共 50 条
  • [21] Performance of a Microdialysis-Based Continuous Glucose Monitoring (CGM) System
    Zijlstra, Eric
    Heise, Tim
    Kuennecke, Wolfgang
    DIABETES, 2012, 61 : A2 - A2
  • [22] A Multistep Algorithm for Processing and Calibration of Microdialysis Continuous Glucose Monitoring Data
    Mahmoudi, Zeinab
    Johansen, Mette Dencker
    Christiansen, Jens Sandahl
    Hejlesen, Ole Kristian
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (10) : 825 - 835
  • [23] Performance of a microdialysis-based continuous glucose monitoring (CGM) system
    Zijlstra, E.
    Heise, T.
    Kuennecke, W.
    DIABETOLOGIA, 2012, 55 : S429 - S429
  • [24] A numerical analysis of continuous glucose monitoring method using a microdialysis technique
    Koseki, O
    Tamura, T
    Sumino, T
    Ogawa, M
    Togawa, T
    Tsuchiya, K
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1771 - 1774
  • [25] Glucose-monitoring with continuous subcutaneous microdialysis in neonatal diabetes mellitus
    Baumeister, F. A. M.
    Hack, A.
    Busch, R.
    KLINISCHE PADIATRIE, 2006, 218 (04): : 230 - 232
  • [26] Ex vivo continuous glucose monitoring with microdialysis technique:: The example of GlucoDay
    Ricci, Francesco
    Moscone, Danila
    Palleschi, Giuseppe
    IEEE SENSORS JOURNAL, 2008, 8 (1-2) : 63 - 70
  • [27] Mass transfer properties of microdialysis probe for monitoring glucose level in subcutaneous tissues
    Okouchi, T
    Ohashi, K
    Kimura, M
    Sudoh, M
    KAGAKU KOGAKU RONBUNSHU, 1998, 24 (02) : 228 - 232
  • [28] A MICRODIALYSIS PROBE COUPLED WITH A MINIATURIZED THERMAL GLUCOSE SENSOR FOR IN-VIVO MONITORING
    AMINE, A
    DIGUA, K
    XIE, B
    DANIELSSON, B
    ANALYTICAL LETTERS, 1995, 28 (13) : 2275 - 2286
  • [29] BIOSENSOR AND MICRODIALYSIS FOR MONITORING GLUCOSE
    BOUTELLE, MG
    FELLOWS, LK
    FRAY, A
    FILLENZ, M
    JOURNAL OF NEUROCHEMISTRY, 1994, 63 : S44 - S44
  • [30] Subcutaneous a continuous glucose monitoring - Feasibility of a new microdialysis-based glucose sensor system
    Jungheim, K
    Wientjes, KJ
    Heinemann, L
    Lodwig, V
    Koschinsky, T
    Koschinsky, T
    Schoonen, AJ
    DIABETES CARE, 2001, 24 (09) : 1696 - 1697