VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE

被引:6
|
作者
Devnani, H. [1 ]
Singh, P. [1 ]
Saxena, S. [1 ]
Satsangee, S. P. [1 ]
机构
[1] Dayalbagh Educ Inst, Univ Sci Instrumentat Ctr, Agra 282005, UP, India
关键词
Rupatadine; Graphene; Voltammetry; Electrochemical Impedance;
D O I
10.13040/IJPSR.0975-8232.5(11).4792-99
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Electrochemical behavior of rupatadine, an anti- allergic drug was studied at graphene modified glassy carbon electrode in Britton-Robinson buffer (pH 6.5) by square wave voltammetry (frequency, 50 Hz; amplitude, 0.02 V; step potential, 0.005 V) and cyclic voltammetry (scan rates, 20- 100 mV/s) techniques. Cyclic voltammetry revealed the oxidation of rupatadine corresponding to N-dealkylation which is the major metabolic pathway of rupatadine in human body. Atomic force microscopy, scanning electron microscopy and electrochemical impedance spectroscopy were used to study the surface characteristics of the fabricated sensor. The electrode dynamic parameters were investigated and the oxidation mechanism was proposed. Lower limit of detection and quantification were achieved with the modified sensor as compared to the bare sensor due to enhancement in electron transfer process at the surface of modified sensor owing to greater electroactive surface area. The limit of detection was found to be 56.78 ng/ml and limit of quantification, 172.06 ng/ml at graphene modified glassy carbon electrode.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Electrochemical behavior and voltammetric determination of ammonium dinitramide using a graphene film modified glassy carbon electrode
    Najafi, Mostafa
    Darabi, Salman
    ELECTROCHIMICA ACTA, 2014, 121 : 315 - 320
  • [22] Voltammetric determination of sumatriptan based on a graphene/gold nanoparticles/Nafion composite modified glassy carbon electrode
    Sanghavi, Bankim J.
    Kalambate, Pramod K.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    TALANTA, 2014, 120 : 1 - 9
  • [23] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Palanisamy, Selvakumar
    Ramaraj, Sayee Kannan
    Chen, Shen-Ming
    Velusamy, Vijayalakshmi
    Yang, Thomas C. K.
    Chen, Tse-Wei
    MICROCHIMICA ACTA, 2017, 184 (04) : 1051 - 1057
  • [24] Electrochemical Behavior and Voltammetric Determination of Curcumin at Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Jing
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (04) : 749 - 756
  • [25] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Selvakumar Palanisamy
    Sayee Kannan Ramaraj
    Shen-Ming Chen
    Vijayalakshmi Velusamy
    Thomas C. K. Yang
    Tse-Wei Chen
    Microchimica Acta, 2017, 184 : 1051 - 1057
  • [26] Stripping voltammetric analysis of dicofol on graphene-modified glassy carbon electrode
    Kocak, Berna
    Er, Engin
    Celikkan, Huseyin
    IONICS, 2015, 21 (08) : 2337 - 2344
  • [27] Stripping voltammetric analysis of dicofol on graphene-modified glassy carbon electrode
    Berna Koçak
    Engin Er
    Hüseyin Çelikkan
    Ionics, 2015, 21 : 2337 - 2344
  • [28] Determination of Rutin by a Graphene-Modified Glassy Carbon Electrode
    Lei, Yan
    Du, Danxin
    Tang, Lina
    Tan, Chenkun
    Chen, Keli
    Zhang, Guo-Jun
    ANALYTICAL LETTERS, 2015, 48 (06) : 894 - 906
  • [29] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    ANALYST, 2002, 127 (01) : 129 - 134
  • [30] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &