Fire Behaviour of Concrete Columns with Restrained Thermal Elongation

被引:5
|
作者
Martins, Alberto Miguel B. [1 ]
Rodrigues, Joao Paulo C. [1 ]
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Civil Engn, Rua Luis Reis Santos, P-3030788 Coimbra, Portugal
关键词
D O I
10.1260/2040-2317.2.4.319
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental and numerical study to clarify the influence of the surrounding building structure in the fire behaviour of reinforced concrete columns with restrained thermal elongation. The parameters studied were: the longitudinal reinforcement ratio, the slenderness of the column and the stiffness of the surrounding structure to the column in fire. The experimental study was complemented by a numerical study carried out using the finite element program SAFIR. Simplified calculation methods proposed in EN1992-1-2 were also used to evaluate the fire resistance of the tested columns. From the application of the 500 degrees C isotherm method, proposed in EN1992-1-2, it can be noticed that this method led to smaller values of the fire resistance than those obtained in the experimental tests. The tabulated data method A, proposed in EN1992-1-2, proved to be very conservative.
引用
收藏
页码:319 / 331
页数:13
相关论文
共 50 条
  • [21] Realistic modelling of thermal and structural behaviour of unprotected concrete filled tubular columns in fire
    Ding, J.
    Wang, Y. C.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (10) : 1086 - 1102
  • [22] Fire behaviour of concrete filled elliptical steel columns
    Espinos, Ana
    Gardner, Leroy
    Romero, Manuel L.
    Hospitaler, Antonio
    THIN-WALLED STRUCTURES, 2011, 49 (02) : 239 - 255
  • [23] Behaviour of restrained concrete filled square double-skin and double-tube hollow columns in case of fire
    Lopes, Ruben F. R.
    Rodrigues, Joao Paulo C.
    ENGINEERING STRUCTURES, 2020, 216
  • [24] Fire resistance of restrained composite columns made of concrete filled hollow sections
    Rodrigues, Joao Paulo C.
    Laim, Luis
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 133 : 65 - 76
  • [25] Residual Axial Behavior of Restrained Reinforced Concrete Columns Damaged by a Standard Fire
    Alhadid, Mohamed Monir A.
    Youssef, Maged A.
    FIRE-SWITZERLAND, 2022, 5 (02):
  • [26] Coupled Structural-thermal Calculations for Restrained Steel Columns in Fire
    Kwasniewski, Laslaw
    Ali, Faris
    Balcerzak, Marcin
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2013, 4 (01) : 59 - 70
  • [27] Comparing fire behaviour of restrained hollow stainless steel with carbon steel columns
    Rodrigues, Joao Paulo C.
    Laim, Luis
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 153 : 449 - 458
  • [28] Experimental analysis of built-up closed cold-formed steel columns with restrained thermal elongation under fire conditions
    Craveiro, Helder D.
    Rodrigues, Joao Paulo C.
    Laim, Luis
    THIN-WALLED STRUCTURES, 2016, 107 : 564 - 579
  • [29] Effect of transient creep on the behaviour of reinforced concrete columns in fire
    Sadaoui, Arezki
    Khennane, Amar
    ENGINEERING STRUCTURES, 2009, 31 (09) : 2203 - 2208
  • [30] Predicting the fire resistance behaviour of high strength concrete columns
    Kodur, VKR
    Wang, TC
    Cheng, FP
    CEMENT & CONCRETE COMPOSITES, 2004, 26 (02): : 141 - 153