Fire Behaviour of Concrete Columns with Restrained Thermal Elongation

被引:5
|
作者
Martins, Alberto Miguel B. [1 ]
Rodrigues, Joao Paulo C. [1 ]
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Civil Engn, Rua Luis Reis Santos, P-3030788 Coimbra, Portugal
关键词
D O I
10.1260/2040-2317.2.4.319
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental and numerical study to clarify the influence of the surrounding building structure in the fire behaviour of reinforced concrete columns with restrained thermal elongation. The parameters studied were: the longitudinal reinforcement ratio, the slenderness of the column and the stiffness of the surrounding structure to the column in fire. The experimental study was complemented by a numerical study carried out using the finite element program SAFIR. Simplified calculation methods proposed in EN1992-1-2 were also used to evaluate the fire resistance of the tested columns. From the application of the 500 degrees C isotherm method, proposed in EN1992-1-2, it can be noticed that this method led to smaller values of the fire resistance than those obtained in the experimental tests. The tabulated data method A, proposed in EN1992-1-2, proved to be very conservative.
引用
收藏
页码:319 / 331
页数:13
相关论文
共 50 条
  • [1] Fire Behaviour of Circular Concrete Columns with Restrained Thermal Elongation
    Rodrigues, Joao Paulo C.
    Laim, Luis M.
    Korzen, Manfred
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2014, 12 (09) : 289 - 298
  • [2] Fire resistance of reinforced concrete columns with elastically restrained thermal elongation
    Martins, Alberto M. B.
    Rodrigues, Joao Paulo C.
    ENGINEERING STRUCTURES, 2010, 32 (10) : 3330 - 3337
  • [3] Fire resistance of concrete filled circular hollow columns with restrained thermal elongation
    Pires, Tiago A. C.
    Rodrigues, Joao Paulo C.
    Rego Silva, Jose J.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 77 : 82 - 94
  • [4] Fire resistance of steel columns with restrained thermal elongation
    Moura Correia, Antonio Jose P.
    Rodrigues, Joao Paulo C.
    FIRE SAFETY JOURNAL, 2012, 50 : 1 - 11
  • [5] The behaviour of rotationally restrained concrete filled tubular columns in fire
    School of Mechanical, Aerospace and Civil Engineering , University of Manchester, PO Box 88, Manchester, M60 1QD, United Kingdom
    Weld. World, SPEC. ISS. (379-385):
  • [6] Fire resistance of partially encased steel columns with restrained thermal elongation
    Moura Correia, Antonio J. P.
    Rodrigues, Joao Paulo C.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (04) : 593 - 601
  • [7] A simplified calculation method for fire design of steel columns with restrained thermal elongation
    Moura Correia, Antonio J. P.
    Rodrigues, Joao Paulo C.
    Gomes, Fernando C. T.
    COMPUTERS & STRUCTURES, 2013, 116 : 20 - 34
  • [8] Finite element analysis on fire resistance behaviors of PEC columns with restrained thermal elongation
    Jin, X. F.
    Liang, S. T.
    Mao, X. Y.
    SUSTAINABLE BUILDINGS AND STRUCTURES, 2016, : 121 - 124
  • [9] Critical temperature of steel columns with restrained thermal elongation
    Instituto Superior Tecnico, Lisbon, Portugal
    Fire Saf J, 3 (211-227):
  • [10] Fire resistance of steel columns with elastically restrained axial elongation and bending
    Valente, JC
    Neves, IC
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 52 (03) : 319 - 331