EVALUATION OF GROUND RESISTANCE OF A GROUNDING GRID OF ANY SHAPE

被引:19
|
作者
THAPAR, B [1 ]
GEREZ, V [1 ]
BALAKRISHNAN, A [1 ]
BLANK, DA [1 ]
机构
[1] BONNEVILLE POWER ADM,DIV SUBSTAT ENGN,PORTLAND,OR
关键词
GROUNDING; GROUND RESISTANCE; GROUNDING GRIDS; SUBSTATION GROUNDING;
D O I
10.1109/61.131122
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A large number of grounding grids in substations have shapes other than a square or a rectangle, whereas the formulas and graphs for the ground resistance of a grounding grid available in the literature are applicable only to nearly square or rectangular grids. A new simple equation for the estimation of ground resistance applicable to any practical shape of the grid is presented in the paper. The results obtained with this equation have been compared with the accurate results obtained from the computer and the results of the analog model tests.
引用
收藏
页码:640 / 647
页数:8
相关论文
共 50 条
  • [31] A new approach of testability evaluation for grounding grid corrosion diagnosis
    Liu Jian
    Wang Shuqi
    Ni Yunfeng
    Li Zhizhong
    Wang Sen
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 804 - 808
  • [32] Measurement of resistance of a grounding grid model using magnetic field sensors
    Davalbhakta, Aneesh A.
    Mahajan, Satish M.
    PROCEEDINGS OF THE 40TH SOUTHEASTERN SYMPOSIUM ON SYSTEM THEORY, 2008, : 174 - +
  • [33] FORMULA FOR RESISTANCE OF SUBSTATION GROUNDING GRID IN 2-LAYER SOIL
    SALAMA, MMA
    ELSHERBINY, MM
    CHOW, YL
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) : 1255 - 1262
  • [34] Modeling Research on Time-Varying Impulse Resistance of Grounding Grid
    Wang Tao
    Hu Xianzhe
    Li Yangping
    Wang Qi
    ADVANCES IN INTERNET, DATA & WEB TECHNOLOGIES, 2018, 17 : 1018 - 1026
  • [35] Evaluation of grounding performance of energized substation by ground current measurement
    Choi, J. K.
    Ahn, Y. H.
    Woo, J. W.
    Jung, G. J.
    Han, B. S.
    Kim, K. C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (11) : 1490 - 1494
  • [36] Decreasing grounding resistance of substation by deep-ground-well method
    He, JL
    Yu, G
    Yuan, JP
    Zeng, R
    Zhang, B
    Zou, J
    Guan, ZC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 738 - 744
  • [37] Effect of soil characteristics on the impulse grounding resistance of substation ground grids
    Gao, Bing
    Wang, Zhengping
    Wei, Minglei
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 107 - 108
  • [38] Modeling and Research on Grounding Impedance of Large Ground Grid under Complex Geological Conditions
    Ren, Zhangao
    He, Zhiqiang
    Li, Xin
    Wang, Muxue
    Yan, Jiaying
    Song, Xianqi
    Bi, Yueqi
    Yang, Meng
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 92 - 96
  • [39] Evaluation of the Grounding Resistance of Conductors Buried in Steplike Terrain
    Kumar, Udaya
    Pal, Rupam
    Paramesha, K.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (06) : 5130 - 5138
  • [40] A simple formula of grounding grid resistance in vertical two-layer soil
    Cao, Xiaobin
    Wu, Guangning
    Li, Shenglin
    Zhou, Weiming
    Li, RuiFang
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1501 - 1505