STEREOTAXIC FINE-NEEDLE ASPIRATION CYTOLOGY OF NONPALPABLE BREAST-LESIONS - INITIAL EXPERIENCE IN A TERTIARY-CARE INSTITUTION

被引:0
|
作者
ILES, SE
MACGREGOR, JH
BODURTHA, AJ
BERNARDO, AI
DANIELS, C
机构
[1] FOOTHILLS PROV GEN HOSP,DEPT RADIOL SCI & DIAGNOST IMAGING,CALGARY,AB,CANADA
[2] VICTORIA GEN HOSP,DEPT SURG,HALIFAX B3H 2Y9,NS,CANADA
[3] VICTORIA GEN HOSP,DEPT PATHOL,HALIFAX B3H 2Y9,NS,CANADA
关键词
MAMMOGRAPHY; NEEDLE BIOPSY; BREAST DISEASE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the accuracy of stereotactic fine-needle aspiration cytology in the diagnosis of nonpalpable breast lesions, this procedure was performed in 226 consecutive patients, all women, immediately before needle localization and excision of the lesions. The patients were treated at a tertiary-care hospital between December 1989 and October 1991. The cytologic results (lesion benign, atypical, suspicious or malignant or insufficient material for interpretation) were compared with the histologic findings and the degree of suspicion (low, slight or high) on the basis of mammographic examination. The aspiration procedures were successful in only 159 patients (70.4%), and for 155 of these, histologic findings were available for correlation. The number of unsatisfactory specimens in this group was large: 65 of 155 (42%). When unsatisfactory specimens were included in the calculations and a cytologic finding of a suspicious or malignant lesion was treated as positive, the sensitivity of fine-needle aspiration cytology for malignancy was 23% (8/35) and the specificity 53% (63/120). The positive and negative predictive values were 89% (8/9) and 78% (63/81) respectively. A cytologic finding that the lesion was benign was unreliable in lesions for which the mammographic suspicion of malignancy was slight or high (4 of 30 malignant lesions with slight mammographic suspicion and 4 of 7 with high mammographic suspicion were classified as benign on the basis of the cytologic examination). Of the 24 cases with atypical cytologic findings, 10 involved malignancy. The positive and negative predictive values were better when the mammographic degree of suspicion and the cytologic results were combined: for the 20 patients with low suspicion and benign cytologic findings, the negative predictive value was 100%, and for the 7 patients with high suspicion and positive cytologic findings, the positive predictive value was also 100%. The technical limitations of the technique, the large number of unsatisfactory specimens and the suboptimal diagnostic accuracy limited the diagnostic benefit of fine-needle aspiration cytology at the authors' institution. If this method is to be used, it should be performed with meticulous attention to technique and careful assessment of the results.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 50 条
  • [41] Spectrum of Adrenal Lesions on Fine-Needle Aspiration Cytology: A Tertiary Care Centre Experiencey
    Kaur, Pavneet
    Soni, Ankita
    Tyagi, Ruchita
    Kaur, Harpreet
    Selhi, Kanwarpal S.
    JOURNAL OF LABORATORY PHYSICIANS, 2022, 14 (03) : 231 - 236
  • [42] POSITIVE PREDICTIVE VALUE OF FINE NEEDLE ASPIRATION CYTOLOGY OF BREAST-LESIONS
    CIATTO, S
    CECCHINI, S
    GRAZZINI, G
    IOSSA, A
    BARTOLI, D
    CARIAGGI, MP
    BULGARESI, P
    ACTA CYTOLOGICA, 1989, 33 (06) : 894 - 898
  • [43] Stereotactic fine-needle aspiration cytology of nonpalpable breast lesions - Institut Curie's experience of 243 histologically correlated cases
    Cote, JF
    Klijanienko, J
    Meunier, M
    Zafrani, B
    Thibault, F
    Clough, K
    Asselain, B
    Vielh, P
    CANCER CYTOPATHOLOGY, 1998, 84 (02) : 77 - 83
  • [44] Stereotaxic needle-core biopsy and fine-needle aspiration biopsy in the diagnosis of nonpalpable breast lesions: Controversies and future prospects
    Lifrange, E
    Kridelka, F
    Colin, C
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (01) : 39 - 47
  • [45] Fine-needle aspiration cytology of spindle cell lesions of the breast
    Chhieng, DC
    Cangiarella, JF
    Waisman, J
    Fernandez, G
    Cohen, JM
    CANCER CYTOPATHOLOGY, 1999, 87 (06) : 359 - 371
  • [46] Fine needle aspiration cytology versus percutaneous biopsy of nonpalpable breast lesions
    Meunier, M
    Clough, K
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 42 (01) : 10 - 16
  • [47] Fine-needle Aspiration Cytology of the Breast
    Berner, Aasmund
    Sauer, Torill
    ULTRASTRUCTURAL PATHOLOGY, 2011, 35 (04) : 162 - 167
  • [48] PROSPECTIVE EVALUATION OF RADIOLOGICALLY DIRECTED FINE NEEDLE ASPIRATION BIOPSY OF NONPALPABLE BREAST-LESIONS
    MASOOD, S
    FRYKBERG, E
    MITCHUM, D
    MCLELLAN, G
    SCALAPINO, M
    BULLARD, J
    LABORATORY INVESTIGATION, 1989, 60 (01) : A60 - A60
  • [49] EVALUATION OF NONPALPABLE BREAST-LESIONS - EXPERIENCE IN A TRAINING INSTITUTION
    HALL, WC
    AUST, JB
    GASKILL, HV
    POTTER, JM
    FLOURNOY, JG
    CRUZ, AB
    AMERICAN JOURNAL OF SURGERY, 1986, 151 (04): : 467 - 469
  • [50] FINE NEEDLE ASPIRATION CYTOLOGY EVALUATION OF BREAST-LESIONS IN YOUNG-WOMEN
    MORRIS, RC
    BETSILL, WL
    ACTA CYTOLOGICA, 1984, 28 (05) : 644 - 644