ONLINE SOLID-PHASE EXTRACTION THERMAL-DESORPTION FOR INTRODUCTION OF LARGE VOLUMES OF AQUEOUS SAMPLES INTO A CAPILLARY GAS-CHROMATOGRAPH .2.

被引:35
|
作者
VREULS, JJ
DEJONG, GJ
GHIJSEN, RT
BRINKMAN, UAT
机构
[1] Free University, Department of Analytical Chemistry de Boelelaan 1083, Amsterdam
[2] Analytical Development Department, Weesp, 1380 DA
关键词
SOLID PHASE EXTRACTION; THERMAL DESORPTION; ONLINE; AQUEOUS SAMPLES; GAS CHROMATOGRAPHY;
D O I
10.1002/mcs.1220050404
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A module for combined solid-phase extraction and thermal desorption (SPETD) was incorporated into a system for automated GC analysis. Solid-phase extraction of analytes from water could be carried out after injection of an aqueous sample of 100 muL either by a loop using the carrier gas for sample introduction or manually with a syringe. After drying of the stationary phase by the carrier gas at a high flow rate, thermal desorption could be carried out at temperatures up to 300-350-degrees-C. Suitable packing materials for the liner in the SPETD module, i.e., materials which efficiently trap the organic compounds from an aqueous Solution and are sufficiently thermostable, include Tenax and carbon-based phases. as well as a silylated alkyl-modified silica. With the latter, however, the problem of efficient drying after sorption still must be solved. Each phase has its own application range which, from among the analytes which are trapped during sorption, is determined at the volatile end by losses occurring during drying by helium purging, and at the nonvolatile end by losses due to incomplete release during thermal desorption. From this study (using n-alkanes, chlorobenzenes, and chlorophenols as test solutes), it appears that the Tenax phases, Tenax-TA and Tenax-GR, have the widest application range; essentially quantitative recoveries were obtained for C-10 through C26 n-alkanes. The carbon-based phases appear to be useful for relatively volatile compounds, i. e., up to C19 n-alkanes. Each phase gave good recoveries for two test mixtures containing chlorobenzenes and chlorophenols dissolved in 100 muL of water at the 10 ppb level.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [21] Solid-Phase Extraction and Large-Volume Sample Stacking-Capillary Electrophoresis for Determination of Artificial Sweeteners in Water Samples
    Camargo Medrano, Lorena
    Francisco Flores-Aguilar, Juan
    Islas, Gabriela
    Antonio Rodriguez, Jose
    Samuel Ibarra, Israel
    FOOD ANALYTICAL METHODS, 2019, 12 (02) : 526 - 533
  • [22] Solid-Phase Extraction and Large-Volume Sample Stacking-Capillary Electrophoresis for Determination of Artificial Sweeteners in Water Samples
    Lorena Camargo Medrano
    Juan Francisco Flores-Aguilar
    Gabriela Islas
    José Antonio Rodríguez
    Israel Samuel Ibarra
    Food Analytical Methods, 2019, 12 : 526 - 533
  • [23] RECOVERY OF PICLORAM AND 2,4-DICHLOROPHENOXYACETIC ACID FROM AQUEOUS SAMPLES BY REVERSED-PHASE SOLID-PHASE EXTRACTION
    WELLS, MJM
    MICHAEL, JL
    ANALYTICAL CHEMISTRY, 1987, 59 (13) : 1739 - 1742
  • [24] Direct Determination of Pyrethroids in Aqueous Samples by a Metal Organic Framework "MIL-101(Cr)" Sorbent for Solid-Phase Extraction and Thermal Desorption Coupled with GC-FID
    Torabizadeh, Mahsa
    Tabar-Heydar, Kourosh
    Ahmadi, Seyyed Hamid
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (08) : 1047 - 1056
  • [25] Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction gas chromatography mass selective detection
    Louter, AJH
    vanBeekvelt, CA
    Montanes, PC
    Slobodnik, J
    Vreuls, JJ
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (01) : 67 - 83
  • [26] Solid-phase extraction of l-muscone from aqueous samples with amberlite XAD-4 for gas chromatographic assay
    Paik, MJ
    Kim, KR
    ARCHIVES OF PHARMACAL RESEARCH, 2004, 27 (05) : 539 - 543
  • [27] Direct Determination of Pyrethroids in Aqueous Samples by a Metal Organic Framework “MIL-101(Cr)” Sorbent for Solid-Phase Extraction and Thermal Desorption Coupled with GC-FID
    Mahsa Torabizadeh
    Kourosh Tabar-Heydar
    Seyyed Hamid Ahmadi
    Journal of Analytical Chemistry, 2022, 77 : 1047 - 1056
  • [28] Solid-phase extraction of l-muscone from aqueous samples with amberlite XAD-4 for gas chromatographic assay
    Man-Jeong Paik
    Kyoung-Rae Kim
    Archives of Pharmacal Research, 2004, 27 : 539 - 543
  • [29] Determination of illicit drugs in aqueous environmental samples by online solid-phase extraction coupled to liquid chromatography-tandem mass spectrometry
    Yao, Bo
    Lian, Lushi
    Pang, Weihai
    Yin, Daqiang
    Chan, Shen-An
    Song, Weihua
    CHEMOSPHERE, 2016, 160 : 208 - 215
  • [30] Simultaneous determination of preservatives in soft drinks, yogurts and sauces by a novel solid-phase extraction element and thermal desorption-gas chromatography
    Wang, Lili
    Zhang, Xiao
    Wang, Yiping
    Wang, Wei
    ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 62 - 67