Evaluation of Triple-energy Window Method with Two Approximations for Scatter Correction Studies in Single-photon Emission Computed Tomography Imaging Using GATE

被引:1
|
作者
Seifabadi, Mohammad [1 ]
机构
[1] Azad Univ Sci & Res Branch, Nucl Engn Dept, Tehran, Iran
关键词
gate; scatter correction; single-photon emission computed tomography; triple-energy window;
D O I
10.1016/j.jmir.2015.04.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Simulations using Monte Carlo packages are increasingly used in nuclear imaging for positron emission tomographic and single-photon emission computed tomographic applications, either for modeling imaging systems or developing algorithms for analysis improvement of image quantifications. This work implemented a GEANT4-based single- photon emission computed tomographic simulation system, GATE, to evaluate the performance of two scatter correction methods: the triple-energy window method using trapezoidal approximation and the triple-energy window method using triangular approximation. A cold-spot hot-background phantom and a resolution phantom were simulated to generate projection images for scatter correction. Both methods were not found to have strictly valid assumptions. A comparative assessment of these two methods was made based on image contrast improvement, image mottle level, and image resolution improvement. Results showed that triangular approximation was better than trapezoidal approximation for contrast improvement with greater image mottle level and some improvement in the resolution of the resolution phantom for both approximations, but trapezoidal approximation with these criteria was better than triangular approximation. A compromise between the contrast improvement and the image mottle level exists. Neither of the two methods performed best for all three criteria.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [31] Does Single Computed Tomography Attenuation Correction able to Surrogate Serial Computed Tomography Attenuation Correction in Single-Photon Emission Computed Therapy Imaging for Peptide Receptor Radionuclide Therapy Dosimetry Result?
    Said, Mohamad
    Razak, Hairil
    Musarudin, Marianie
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (02) : 189 - 193
  • [32] Energy Window Optimization Using Triple Energy Window Scatter Correction Method for In-111 SPECT Imaging: A SIMIND Monte Carlo Study
    Asmi, Hicham
    Bentayeb, Farida
    Bouzekraoui, Youssef
    Bonutti, Faustino
    Iranian Journal of Medical Physics, 2021, 18 (05) : 300 - 305
  • [34] Ictal single-photon emission computed tomography imaging in extratemporal lobe epilepsy using statistical parametric mapping
    Knowlton, RC
    Lawn, ND
    Mountz, JM
    Buddhiwardhan, O
    Miller, S
    Burneo, JG
    Kuzniecky, RI
    JOURNAL OF NEUROIMAGING, 2004, 14 (04) : 324 - 330
  • [35] Prediction of sentinel lymph node status using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging of breast cancer
    Tomiguchi, Mai
    Yamamoto-Ibusuki, Mutsuko
    Yamamoto, Yutaka
    Fujisue, Mamiko
    Shiraishi, Shinya
    Inao, Touko
    Murakami, Kei-ichi
    Honda, Yumi
    Yamashita, Yasuyuki
    Iyama, Ken-ichi
    Iwase, Hirotaka
    SURGERY TODAY, 2016, 46 (02) : 214 - 223
  • [36] Myocardial perfusion imaging using single-photon emission computed tomography with cadmium-zinc-telluride technology
    Konsek-Komorowska, Sonia J.
    Peczkowska, Mariola
    Cwikla, Jaroslaw B.
    NUCLEAR MEDICINE REVIEW, 2022, 25 (02) : 119 - 126
  • [37] Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography
    Huang, Yong
    Lu, Yangjia
    Li, Ganlong
    Lai, Xinsheng
    Zhang, Hong
    Tang, Chunzhi
    Yang, Junjun
    Wik, Gustav
    NEURAL REGENERATION RESEARCH, 2011, 6 (06) : 428 - 434
  • [38] Prediction of sentinel lymph node status using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging of breast cancer
    Mai Tomiguchi
    Mutsuko Yamamoto-Ibusuki
    Yutaka Yamamoto
    Mamiko Fujisue
    Shinya Shiraishi
    Touko Inao
    Kei-ichi Murakami
    Yumi Honda
    Yasuyuki Yamashita
    Ken-ichi Iyama
    Hirotaka Iwase
    Surgery Today, 2016, 46 : 214 - 223
  • [39] Radiation dose reduction in myocardial perfusion imaging single-photon emission computed tomography/computed tomography using a dose-tracking software
    Serreli, Giulio
    Ruffini, Livia
    Ortenzia, Ornella
    Cidda, Carla
    Lazzara, Chiara
    Ghetti, Caterina
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (10) : 894 - 900
  • [40] 67Ga planar imaging with a low-energy collimator and scatter correction using the triple energy window method
    Okada, J
    Imai, Y
    Tamada, H
    Kawashiro, O
    Yui, N
    Togawa, T
    Kinoshita, F
    Ito, H
    NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (07) : 647 - 657