COMPARISON OF FROST AND DEFROST PERFORMANCE BETWEEN MICROCHANNEL COIL AND FIN-AND-TUBE COIL FOR HEAT PUMP SYSTEMS

被引:14
|
作者
Padhmanabhan, Sankar [1 ]
Cremaschi, Lorenzo [2 ]
Fisher, Daniel [2 ]
机构
[1] Johnson Controls Inc, Global Heat Transfer Ctr Excellence, Norman, OK 73069 USA
[2] Oklahoma State Univ, Sch Mech & Aerosp Engn, Stillwater, OK 74078 USA
关键词
Microchannel; finned-tube; frost growth; heat pump; water retention;
D O I
10.1142/S2010132511000600
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a comparison of frost and defrost cycling performance between a microchannel heat exchanger with louvered fin and a fin-and-tube heat exchanger with straight fins employed as outdoor coils of a 14 kW (48 000 Btu/h) heat pump system. In addition to temperature, pressure and flow rate measurements taken at various locations of the systems, the fin-base and tube wall surface temperature were also recorded by using fine-gauge precalibrated thermocouples on the coils. Further, load cells were used to measure the mass of frost accumulation during heating tests. Data showed that the frosting time of the microchannel heat exchanger is more than 50% shorter than for the fin-and-tube heat exchanger, which is chosen as the baseline system. The average heating capacity and system performance over a frost -defrost cycle are also lower for the system with microchannel heat exchangers. Higher frost growth rate was mainly due to augmented temperature difference between air and the surface of the heat exchanger, and preferential frost nucleation sites on the louvered fins and microchannel tubes. Removal of residual water in the microchannel heat exchanger did not improve the frost performance significantly. Blowing nitrogen on the microchannel coil after defrost removed any visible water retained in the coil after the defrost cycle but the cycle time increased only by 4% with respect to wet and frost conditions. The cycle time of the same microchannel coil starting with dry conditions was about 60% longer than the cycle time in wet and frost conditions.
引用
收藏
页码:273 / 284
页数:12
相关论文
共 50 条
  • [1] Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions
    Shao, Liang-Liang
    Yang, Liang
    Zhang, Chun-Lu
    APPLIED ENERGY, 2010, 87 (04) : 1187 - 1197
  • [2] Performance comparison of an air/water heat pump using a minichannel coil as evaporator in replacement of a fin-and-tube heat exchanger
    Garcia-Cascales, J. R.
    Illan-Gomez, F.
    Hidalgo-Mompean, F.
    Ramirez-Rivera, F. A.
    Ramirez-Basal, M. A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 560 - 575
  • [3] Experimental investigation of frost and defrost performance of microchannel heat exchangers for heat pump systems
    Xu, Bo
    Han, Qing
    Chen, Jiangping
    Li, Feng
    Wang, Nianjie
    Li, Dong
    Pan, Xiaoyong
    APPLIED ENERGY, 2013, 103 : 180 - 188
  • [4] Frost formation on fin-and-tube heat exchangers. Part I - Modeling of frost formation on fin-and-tube heat exchangers
    Seker, D
    Karatas, H
    Egrican, N
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04): : 367 - 374
  • [5] Frost formation on fin-and-tube heat exchangers. Part II - Experimental investigation of frost formation on fin-and-tube heat exchangers
    Seker, D
    Karatas, H
    Egrican, N
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04): : 375 - 377
  • [6] Frost Formation Phenomenon in a Fin-and-Tube Heat Exchanger
    Lenic, Kristian
    Trp, Anica
    STROJARSTVO, 2008, 50 (01): : 15 - 22
  • [7] Comparison of the transient behavior of microchannel and fin-and-tube evaporators
    Mader, Gunda
    Fosel, Georg P. F.
    Larsen, Lars F. S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (05): : 1222 - 1229
  • [8] Performance comparison of enhanced fin geometries used in fin-and-tube heat exchangers
    Kang, HC
    Webb, RL
    HEAT TRANSFER 1998, VOL 6: GENERAL PAPERS, 1998, : 273 - 278
  • [9] Study of the performance of heat and mass transfer for fin-tube coil
    Xia, J
    Zou, XX
    Jin, XQ
    Gu, B
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 369 - 372
  • [10] A new model for predicting performance of fin-and-tube heat exchanger under frost condition
    Cui, J.
    Li, W. Z.
    Liu, Y.
    Zhao, Y. S.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2011, 32 (01) : 249 - 260