REPRODUCIBILITY OF LATERAL SPINE SCANS USING DUAL ENERGY X-RAY ABSORPTIOMETRY

被引:68
|
作者
LARNACH, TA [1 ]
BOYD, SJ [1 ]
SMART, RC [1 ]
BUTLER, SP [1 ]
ROHL, PG [1 ]
DIAMOND, TH [1 ]
机构
[1] ST GEORGE HOSP,DEPT ENDOCRINOL,SYDNEY,AUSTRALIA
关键词
BONE; DENSITOMETRY; DUAL ENERGY X-RAY ABSORPTIOMETRY; LATERAL SPINE SCANNING; REPRODUCIBILITY;
D O I
10.1007/BF00334484
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reproducibility of lateral spine dual energy X-ray absorptiometry (LAT DEXA) scans using a Lunar DPX-L scanner was assessed in a cadaveric phantom and in patients. One hundred phantom measurements over 7 months demonstrated a longitudinal stability of 1.7% (coefficient of variation, CV). Additional scans were performed with the phantom rotated by up to 20-degrees in each of the three orthogonal planes to assess the effects of variable patient positioning. Horizontal and vertical rotation of the spine had little effect on the estimated bone mineral density (BMD), however, axial rotation of greater than 8-degrees led to errors in the BMD measurement. One hundred consecutive patients had two lateral scans performed within 1 month. BMD (range 0.10-1.6 g/cm2) was determined for each scan by one operator. Significant overlap from fibs and pelvis was often seen with L2 and L4 vertebrae but one vertebra (L3) could be measured in every case. Intraoperator and interoperator variability was assessed by three experienced operators, each analyzing 10 patients' scans on five separate occasions, and was found to be less than 1.1% for a single vertebra. BMD estimation of vertebral bodies and midslices by lateral DEXA scans (CV% of 3.8% and 4.6%) have a 95% confidence interval of 0.074 g/cm2 and 0.0% g/cm2, respectively for two vertebrae. This variability is due mainly to axial rotation, with operator variability, horizontal rotation, and vertical rotation having little effect on BMD estimation.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 50 条
  • [41] BONE DENSITOMETRY OF THE SPINE AND FEMUR IN CHILDREN BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    KROGER, H
    KOTANIEMI, A
    VAINIO, P
    ALHAVA, E
    BONE AND MINERAL, 1992, 17 (01): : 75 - 85
  • [42] Patient variables impact lumbar spine dual energy X-ray absorptiometry precision
    R. D. Blank
    D. G. Malone
    R. C. Christian
    N. L. Vallarta-Ast
    D. C. Krueger
    M. K. Drezner
    N. C. Binkley
    K. E. Hansen
    Osteoporosis International, 2006, 17 : 768 - 774
  • [43] Patient variables impact lumbar spine dual energy X-ray absorptiometry precision
    Blank, RD
    Malone, DG
    Christian, RC
    Vallarta-Ast, NL
    Krueger, DC
    Drezner, MK
    Binkley, NC
    Hansen, KE
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 (05) : 768 - 774
  • [44] Pitfalls of dual energy x-ray absorptiometry in dialysis: Beware the lumbar spine.
    Stein, MS
    Packham, DK
    Ebeling, PR
    Wark, JD
    Becker, GJ
    KIDNEY INTERNATIONAL, 1997, 51 (04) : 1329 - 1329
  • [45] Assessing Agreement of Lateral Leg Composition Using Dual X-ray Absorptiometry
    Raymond-Pope, Christiana J.
    Bosch, Tyler A.
    Dengel, Donald R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 338 - 338
  • [46] Common errors in dual-energy X-ray absorptiometry scans in imaging centers in Ecuador
    Maldonado, Genessis
    Intriago, Maria
    Larroude, Maria
    Aguilar, Gabriel
    Moreno, Mario
    Gonzalez, Jose
    Vargas, Sara
    Vera, Claudia
    Rios, Karla
    Rios, Carlos
    ARCHIVES OF OSTEOPOROSIS, 2020, 15 (01)
  • [47] Effective dose of dual-energy X-ray absorptiometry scans in children as a function of age
    Thomas, SR
    Kalkwarf, HJ
    Buckley, DD
    Heubi, JE
    JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) : 415 - 422
  • [48] COMMON ERRORS IN DUAL-ENERGY X-RAY ABSORPTIOMETRY SCANS IN IMAGING CENTERS IN ECUADOR
    Intriago, M. J.
    Maldonado, G.
    Larroude, M.
    Aguilar, G.
    Moreno, M.
    Gonzalez, J.
    Vargas, S.
    Vera, C.
    Rios, K.
    Rios, C.
    JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2018, 24 : S141 - S142
  • [49] Optimized interpretation and reporting of dual X-ray absorptiometry (DXA) scans
    Lenchik, L
    Rochmis, P
    Sartoris, DJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (06) : 1509 - 1520
  • [50] Common errors in dual-energy X-ray absorptiometry scans in imaging centers in Ecuador
    Genessis Maldonado
    Maria Intriago
    Maria Larroude
    Gabriel Aguilar
    Mario Moreno
    Jose Gonzalez
    Sara Vargas
    Claudia Vera
    Karla Rios
    Carlos Rios
    Archives of Osteoporosis, 2020, 15