REPRODUCIBILITY OF LATERAL SPINE SCANS USING DUAL ENERGY X-RAY ABSORPTIOMETRY

被引:68
|
作者
LARNACH, TA [1 ]
BOYD, SJ [1 ]
SMART, RC [1 ]
BUTLER, SP [1 ]
ROHL, PG [1 ]
DIAMOND, TH [1 ]
机构
[1] ST GEORGE HOSP,DEPT ENDOCRINOL,SYDNEY,AUSTRALIA
关键词
BONE; DENSITOMETRY; DUAL ENERGY X-RAY ABSORPTIOMETRY; LATERAL SPINE SCANNING; REPRODUCIBILITY;
D O I
10.1007/BF00334484
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reproducibility of lateral spine dual energy X-ray absorptiometry (LAT DEXA) scans using a Lunar DPX-L scanner was assessed in a cadaveric phantom and in patients. One hundred phantom measurements over 7 months demonstrated a longitudinal stability of 1.7% (coefficient of variation, CV). Additional scans were performed with the phantom rotated by up to 20-degrees in each of the three orthogonal planes to assess the effects of variable patient positioning. Horizontal and vertical rotation of the spine had little effect on the estimated bone mineral density (BMD), however, axial rotation of greater than 8-degrees led to errors in the BMD measurement. One hundred consecutive patients had two lateral scans performed within 1 month. BMD (range 0.10-1.6 g/cm2) was determined for each scan by one operator. Significant overlap from fibs and pelvis was often seen with L2 and L4 vertebrae but one vertebra (L3) could be measured in every case. Intraoperator and interoperator variability was assessed by three experienced operators, each analyzing 10 patients' scans on five separate occasions, and was found to be less than 1.1% for a single vertebra. BMD estimation of vertebral bodies and midslices by lateral DEXA scans (CV% of 3.8% and 4.6%) have a 95% confidence interval of 0.074 g/cm2 and 0.0% g/cm2, respectively for two vertebrae. This variability is due mainly to axial rotation, with operator variability, horizontal rotation, and vertical rotation having little effect on BMD estimation.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 50 条
  • [1] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE SPINE IN ANTEROPOSTERIOR AND LATERAL PROJECTIONS
    DUBOEUF, F
    POMMET, R
    MEUNIER, PJ
    DELMAS, PD
    OSTEOPOROSIS INTERNATIONAL, 1994, 4 (02) : 110 - 116
  • [2] REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    CHILIBECK, P
    CALDER, A
    SALE, DG
    WEBBER, C
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (04): : 297 - 302
  • [3] Reproducibility of visual vertebral deformity assessment on lateral X-ray absorptiometry scans and conventional radiographs of the spine.
    Rea, JA
    Li, J
    Blake, GM
    Steiger, P
    Genant, FK
    Fogelman, I
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S285 - S285
  • [4] Dual energy X-ray absorptiometry spine scans to determine abdominal fat in postmenopausal women
    Bea, J. W.
    Blew, R. M.
    Going, S. B.
    Hsu, C. -H.
    Lee, M. C.
    Lee, V. R.
    Caan, B. J.
    Kwan, M. L.
    Lohman, T. G.
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 2016, 28 (06) : 918 - 926
  • [5] Is lateral spine dual energy X-ray absorptiometry of value in diagnosing osteoporosis in women?
    Aoki, TT
    Grecu, EO
    Srinivas, PR
    Arcangeli, MA
    JOURNAL OF INVESTIGATIVE MEDICINE, 1999, 47 (02) : 94A - 94A
  • [6] Quality in dual-energy X-ray absorptiometry scans
    Morgan, Sarah L.
    Prater, Ginnie L.
    BONE, 2017, 104 : 13 - 28
  • [7] CLINICAL REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    WILLIAMSRUSSO, P
    HEALEY, JH
    SZATROWSKI, TP
    SCHNEIDER, R
    PAGET, S
    ALES, K
    SCHWARTZBERG, P
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (02) : 250 - 257
  • [8] Lateral dual X-ray absorptiometry of the lumbar spine: Current status
    Jergas, M
    Genant, HK
    BONE, 1997, 20 (04) : 311 - 314
  • [9] Evaluation of peripheral dual energy X-ray absorptiometry: comparison with single photon absorptiometry of the forearm and dual energy X-ray absorptiometry of the spine or femur
    Mole, PA
    McMurdo, MET
    Paterson, CR
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (844): : 427 - 432
  • [10] The diagnosis of osteoporosis by standard spine dual-energy x-ray absorptiometry and whole body scans
    Christov, V
    Boyanov, M
    Boneva, Z
    Harangoso, E
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 : S35 - S35