Analysis of electromyographic activity in spastic biceps brachii muscle following neural mobilization

被引:17
|
作者
Castilho, Jessica [1 ]
Braun Ferreira, Luiz Alfredo [1 ]
Pereira, Wagner Menna [1 ]
Pasini Neto, Hugo [2 ]
da Silva Morelli, Jose Geraldo [2 ]
Brandalize, Danielle [1 ]
Kerppers, Ivo Ilvan [1 ]
Oliveira, Claudia Santos [2 ]
机构
[1] Univ Estadual Ctr Oeste UNICENTRO, Chopinzinho, Brazil
[2] Univ Nove Julho UNINOVE, Sao Paulo, Brazil
关键词
Neural mobilization; Electromyography; Spasticity;
D O I
10.1016/j.jbmt.2011.12.003
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Introduction: Hypertonia is prevalent in anti-gravity muscles, such as the biceps brachii. Neural mobilization is one of the techniques currently used to reduce spasticity. Objective: The aim of the present study was to assess electromyographic (EMG) activity in spastic biceps brachii muscles before and after neural mobilization of the upper limb contralateral to the hemiplegia. Materials and Methods: Repeated pre-test and post-test EMG measurements were performed on six stroke victims with grade 1 or 2 spasticity (Modified Ashworth Scale). The Upper Limb Neurodynamic Test (ULNT1) was the mobilization technique employed. Results: After neural mobilization contralateral to the lesion, electromyographic activity in the biceps brachii decreased by 17% and 11% for 90 degrees flexion and complete extension of the elbow, respectively. However, the results were not statistically significant (p gt; 0.05). Conclusions: When performed using contralateral techniques, neural mobilization alters the electrical signal of spastic muscles. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [31] Electromyographic, cerebral, and muscle hemodynamic responses during intermittent, isometric contractions of the biceps brachii at three submaximal intensities
    Bhambhani, Yagesh
    Fan, Jui-Lin
    Place, Nicolas
    Rodriguez-Falces, Javier
    Kayser, Bengt
    FRONTIERS IN PHYSIOLOGY, 2014, 5
  • [32] MULTIFRACTAL ANALYSIS OF EMG FOR CLASSIFICATION AND PROGRESSIVE ASSESSMENT OF BICEPS BRACHII MUSCLE STRENGTH
    Subhash, K. M.
    Joseph, K. Paul
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (07)
  • [33] ANALYSIS OF INDUCED ISOMETRIC FATIGUING CONTRACTIONS IN BICEPS BRACHII MUSCLES USING MYOTONOMETRY AND SURFACE ELECTROMYOGRAPHIC MEASUREMENTS
    Banerjee, Shib Sundar
    Sadhukhan, Deboleena
    Arunachalakasi, Arockiarajan
    Swaminathan, Ramakrishnan
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2022, 22 (05)
  • [34] Electromyographic and mechanomyographic responses of the biceps brachii during concentric and eccentric muscle actions to failure at high and low relative loads
    Brian Benitez
    Taylor K. Dinyer-McNeely
    Lindsay McCallum
    Minyoung Kwak
    Pasquale J. Succi
    Haley C. Bergstrom
    European Journal of Applied Physiology, 2023, 123 : 2145 - 2156
  • [35] Accessory heads of the biceps brachii muscle: A systematic review and meta-analysis
    Benes, Michal
    Kachlik, David
    Lev, David
    Kunc, Vojtech
    JOURNAL OF ANATOMY, 2022, 241 (02) : 461 - 477
  • [36] Motor unit activity in biceps brachii muscle during voluntary isovelocity elbow flexion
    Okuno, R
    Maekawa, K
    Akazawa, J
    Yoshida, M
    Akazawa, K
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2005, E88D (06) : 1265 - 1272
  • [37] CHANGE IN MUSCLE ACTIVITY PATTERNS OF THE BRACHIALIS AND BICEPS BRACHII DURING DYNAMIC ELBOW FLEXION
    Date, Shota
    Kurumadani, Hiroshi
    Kurauchi, Kazuya
    Ishii, Yosuke
    Sunagawa, Toru
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2024, 24 (06)
  • [38] Electromyographic and mechanomyographic responses of the biceps brachii during concentric and eccentric muscle actions to failure at high and low relative loads
    Benitez, Brian
    Dinyer-McNeely, Taylor K.
    McCallum, Lindsay
    Kwak, Minyoung
    Succi, Pasquale J.
    Bergstrom, Haley C.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2023, 123 (10) : 2145 - 2156
  • [39] The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii
    Beck, TW
    Housh, TJ
    Johnson, GO
    Weir, JP
    Cramer, JT
    Coburn, JW
    Malek, MH
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (05) : 482 - 495
  • [40] The influence of different jaw positions on the endurance and electromyographic pattern of the biceps brachii muscle in young adults with different occlusal characteristics
    Ferrario, VF
    Sforza, C
    Serrao, G
    Fragnito, N
    Grassi, G
    JOURNAL OF ORAL REHABILITATION, 2001, 28 (08) : 732 - 739