DOBUTAMINE VERSUS DIPYRIDAMOLE-MAGNETIC RESONANCE IMAGING - SAFETY AND SENSITIVITY FOR THE DIAGNOSIS OF CORONARY-ARTERY STENOSES

被引:0
|
作者
BAER, FM
THEISSEN, P
SMOLARZ, K
VOTH, E
SECHTEM, U
SCHICHA, H
HILGER, HH
机构
[1] UNIV COLOGNE,INNERE MED KLIN 3,JOSEPH STELZMANN STR 9,D-50931 COLOGNE,GERMANY
[2] UNIV COLOGNE,NUKL MED KLIN & POLIKLIN,D-50931 COLOGNE,GERMANY
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 1993年 / 82卷 / 08期
关键词
CORONARY ARTERY DISEASE; DIPYRIDAMOLE; DOBUTAMINE; GRADIENT-ECHO MAGNETIC RESONANCE IMAGING;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Safety and sensitivity of gradient-echo magnetic resonance imaging (MRI) for the identification of significant coronary artery stenoses using pharmacologic stress testing was assessed in 61 patients with greater-than-or-equal-to 70 % stenosis of a major coronary artery and a normal left ventricle. After MRI at rest 28 patients underwent dobutamine-MRI during steady-state dobutamine infusion (5, 10, 15 and 20 mug/kg/min) and 33 patients had dipyridamole-MRI after high-dose dipyridamole infusion (0.75 mg/kg over 10 min). All patients additionally performed standard ECG exercise stress testing (EST). Segmental wall motion analysis was performed in basal and midventricular short axis tomograms by two observers. A segment was graded pathologic if transient dobutamine or dipyridamole induced wall motion abnormalities could be detected. For comparison to coronary angiography findings, each segment was assigned to one of the coronary artery perfusion territories. There were no serious side-effects during dobutamine and dipyridamole infusion leading to termination of the study protocol. Peak double product during dobutamine infusion was significantly higher (p < 0.001) than after dipyridamole infusion (18.493 +/- 4.311 versus 12.799 +/- 2.694 mm Hg/min). Overall sensitivity of dobutamine and dipyridamole-MRI for coronary artery disease (CAD) was 85 % and 84 %. Regional asynergy by dobutamine and dipyridamole-MRI was observed in 73 % versus 79 % patients with single- and 100 % versus 92 % with multi-vessel disease. Individual coronary artery stenoses were correctly identified by segmental wall motion abnormalities in 87 % versus 81 % for left anterior descending, 62 % versus 86 % for left circumflex and 78 % versus 92 % for right coronary artery stenoses. In conclusion, dobutamine and dipyridamole-MRI are well tolerated and safe non-exercise dependent tests for detection and localization of hemodynamically significant coronary artery stenoses with a similar diagnostic accuracy but with a better control of stress intensity and duration provided by dobutamine.
引用
收藏
页码:494 / 503
页数:10
相关论文
共 50 条
  • [31] THE EFFECTS OF COMBINED DIPYRIDAMOLE AND DOBUTAMINE STRESS-TESTING IN CORONARY-ARTERY DISEASE PATIENTS
    OSTOJIC, MC
    PICANO, E
    DISTANTE, A
    BELESLIN, BD
    BABIC, RM
    NEDELJKOVIC, MA
    PETRASINOVIC, Z
    STEPANOVIC, J
    STOJKOVIC, S
    STANKOVIC, G
    CIRCULATION, 1992, 86 (04) : 127 - 127
  • [32] DOBUTAMINE STRESS ECHOCARDIOGRAPHY FOR THE DIAGNOSIS AND MANAGEMENT OF CORONARY-ARTERY DISEASE
    TANIMOTO, M
    PAI, RG
    JINTAPAKORN, W
    SHAH, PM
    CLINICAL CARDIOLOGY, 1995, 18 (05) : 252 - 260
  • [33] COMPARISON OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY, DIPYRIDAMOLE STRESS ECHOCARDIOGRAPHY AND EXERCISE STRESS-TESTING FOR DIAGNOSIS OF CORONARY-ARTERY DISEASE
    PREVITALI, M
    LANZARINI, L
    FETIVEAU, R
    POLI, A
    FERRARIO, M
    FALCONE, C
    MUSSINI, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (12): : 865 - 870
  • [34] LOCALIZATION OF A MISPLACED CORONARY-ARTERY STENT BY MAGNETIC-RESONANCE-IMAGING
    MOHIADDIN, RH
    ROBERTS, RH
    UNDERWOOD, R
    ROTHMAN, M
    CLINICAL CARDIOLOGY, 1995, 18 (03) : 175 - 177
  • [35] NUCLEAR-MAGNETIC-RESONANCE IMAGING OF PARTIAL CORONARY-ARTERY OCCLUSION
    SCHAEFER, S
    LANGE, R
    KULKARNI, P
    JANSEN, D
    NUNNALLY, R
    WILLERSON, J
    PESHOCK, R
    CLINICAL RESEARCH, 1987, 35 (03): : A324 - A324
  • [36] Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging
    Dewey, Marc
    Teige, Florian
    Schnapauff, Dirk
    Laule, Michael
    Borges, Adrian C.
    Wernecke, Klaus-Dieter
    Schink, Tania
    Baumann, Gert
    Rutsch, Wolfgang
    Rogalla, Patrik
    Taupitz, Matthias
    Hamm, Bernd
    ANNALS OF INTERNAL MEDICINE, 2006, 145 (06) : 407 - 415
  • [37] CORONARY-ARTERY GRAFT PATENCY AS ASSESSED BY MAGNETIC-RESONANCE-IMAGING
    LOVE, HG
    JENKINS, JPR
    FOSTER, CJ
    ROWLANDS, DJ
    ISHERWOOD, I
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A174 - A174
  • [38] NUCLEAR-MAGNETIC-RESONANCE IMAGING OF MYOCARDIAL-ISCHEMIA DURING DIPYRIDAMOLE EFFECT IN A PARTIAL CORONARY-ARTERY STENOSIS MODEL
    MILLER, DD
    HOLMVANG, G
    GILL, JB
    DRAGOTAKES, D
    KANTOR, HL
    BRADY, TJ
    OKADA, RD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A74 - A74
  • [39] STRESS ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE - A HEAD-TO-HEAD COMPARISON BETWEEN EXERCISE, DOBUTAMINE AND DIPYRIDAMOLE TESTS
    BELESLIN, BD
    OSTOJIC, MC
    STEPANOVIC, J
    PETRASINOVIC, Z
    NEDELJKOVIC, MA
    STOJKOVIC, S
    BABIC, RM
    STANKOVIC, GR
    GOJKOVIC, L
    VASILJEVIC, Z
    CIRCULATION, 1992, 86 (04) : 128 - 128
  • [40] DSA CORONARY FLOW RESERVE IMAGING OF COMPLEX SEQUENTIAL CORONARY-ARTERY STENOSES
    TOGGART, E
    CUSMA, J
    HANGIANDREOU, N
    PEPPLER, W
    FOLTS, J
    VANLYSEL, M
    MISTRETTA, C
    CIRCULATION, 1986, 74 (04) : 486 - 486