FULLY AUTOMATED FLOW-INJECTION SYSTEM FOR QUANTIFYING 1,5-ANHYDRO-D-GLUCITOL IN SERUM

被引:0
|
作者
TANABE, T
UMEGAE, Y
KOYASHIKI, Y
KATO, Y
FUKAHORI, K
TAJIMA, S
YABUUCHI, M
机构
[1] NIPPON KAYAKU CO LTD,DIAGNOST AGENT DEV OFF,CHIYODA KU,TOKYO 102,JAPAN
[2] TOSOH CORP,DIV SCI INSTRUMENT,AYASE,KANAGAWA 252,JAPAN
[3] NIPPON KAYAKU CO LTD,TAKASAKI RES LABS,TAKASAKI,GUMMA 37012,JAPAN
关键词
PYRANOSE OXIDASE; ENZYME REACTOR; DIABETES; ANION-EXCHANGE RESIN;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We have developed a flow-injection system with colorimetric detection to measure 1,5-anhydro-D-glucitol in serum. Serum samples are directly and serially injected into a clean-up column every 3.5 min to remove interferences before the enzymatic reaction. 1,5-Anhydro-D-glucitol, after being passed through the column, is oxidized by immobilized pyranose oxidase (EC 1.1.3.10), and the hydrogen peroxide produced reacts with the chromogen substrate in the presence of immobilized horseradish peroxidase (EC 1.11.1.7) to form Bindshedler's Green, The detection limit was 1.2 mu mol/L (1.2 pmol). The correlation between results obtained with the present system (y) and gas chromatography-mass spectrometry (GO-MS) (x) in samples containing <30 mu mol/L 1,5-anhydro-D-glucitol, including many samples from patients with diabetes mellitus, was y = 0.975x - 0.111 mu mol/L (r = 0.997), which was superior to that obtained between the enzymatic and GO-MS methods. Our system needs only to be set up; it runs without any manual pretreatment, assays 17 samples/h, and shows imprecision (CV) of <2%.
引用
收藏
页码:2006 / 2012
页数:7
相关论文
共 50 条
  • [41] Prognostic value of 1,5-anhydro-d-glucitol incorporating syntax score in acute coronary syndrome
    Morishita, Tetsuji
    Uzui, Hiroyasu
    Mitsuke, Yasuhiko
    Tada, Hiroshi
    HEART AND VESSELS, 2023, 38 (01) : 8 - 17
  • [42] Serum1,5-anhydro-D-glucitol as a new clinical marker for glucose metabolism in type 2 diabetics
    史虹莉
    方京冲
    杨秀芳
    沈稚舟
    朱禧星
    Chinese Medical Journal, 1999, (06)
  • [43] Impact of Serum 1,5-anhydro-d-glucitol Level on The Prediction of Severe Coronary Artery Calcification: An Intravascular Ultrasound Study
    Wada, Hideki
    Dohi, Tomotaka
    Miyauchi, Katsumi
    Takahashi, Norihito
    Endo, Hirohisa
    Kato, Yoshiteru
    Ogita, Manabu
    Okai, Iwao
    Iwata, Hiroshi
    Okazaki, Shinya
    Isoda, Kikuo
    Shimada, Kazunori
    Suwa, Satoru
    Daida, Hiroyuki
    CIRCULATION, 2019, 140
  • [44] Impact of serum 1,5-anhydro-d-glucitol level on the prediction of severe coronary artery calcification: an intravascular ultrasound study
    Wada, Hideki
    Dohi, Tomotaka
    Miyauchi, Katsumi
    Takahashi, Norihito
    Endo, Hirohisa
    Kato, Yoshiteru
    Ogita, Manabu
    Okai, Iwao
    Iwata, Hiroshi
    Okazaki, Shinya
    Isoda, Kikuo
    Shimada, Kazunori
    Suwa, Satoru
    Daida, Hiroyuki
    CARDIOVASCULAR DIABETOLOGY, 2019, 18 (1)
  • [45] Is the 1,5-anhydro-D-glucitol test a promising tool for monitoring compensation and treatment of diabetes mellitus?
    Arbusova, M. I.
    Il'yin, A. V.
    DIABETES MELLITUS, 2010, 13 (01): : 123 - 125
  • [46] Prognostic value of 1,5-anhydro-d-glucitol incorporating syntax score in acute coronary syndrome
    Tetsuji Morishita
    Hiroyasu Uzui
    Yasuhiko Mitsuke
    Hiroshi Tada
    Heart and Vessels, 2023, 38 : 8 - 17
  • [47] Serum1,5-anhydro-D-glucitol as a new clinical marker for glucose metabolism in type 2 diabetics
    史虹莉
    方京冲
    杨秀芳
    沈稚舟
    朱禧星
    中华医学杂志(英文版), 1999, (06) : 91 - 93
  • [48] Impact of serum 1,5-anhydro-d-glucitol level on the prediction of severe coronary artery calcification: an intravascular ultrasound study
    Hideki Wada
    Tomotaka Dohi
    Katsumi Miyauchi
    Norihito Takahashi
    Hirohisa Endo
    Yoshiteru Kato
    Manabu Ogita
    Iwao Okai
    Hiroshi Iwata
    Shinya Okazaki
    Kikuo Isoda
    Kazunori Shimada
    Satoru Suwa
    Hiroyuki Daida
    Cardiovascular Diabetology, 18
  • [49] Quantification of 1,5-anhydro-D-glucitol in urine by automated borate complex anion-exchange chromatography with an immobilized enzyme reactor
    Tanabe, T
    Tajima, S
    Suzuki, T
    Okawa, E
    Machida, R
    Ichimura, S
    Yabuuchi, M
    JOURNAL OF CHROMATOGRAPHY B, 1997, 692 (01): : 23 - 30
  • [50] The 1,5-anhydro-D-glucitol plasma level and HbA(1)c concentration in healthy subjects.
    Dworacka, M
    Szczawinska, K
    Winiarska, H
    Zozulinska, D
    Kuczynski, S
    DIABETOLOGIA, 1997, 40 : 2307 - 2307