COMPENSATORS FOR 3-DIMENSIONAL TREATMENT PLANNING

被引:36
|
作者
MAGERAS, GS
MOHAN, R
BURMAN, C
BAREST, GD
KUTCHER, GJ
机构
[1] Department of Medical Physics, Memorial Sloan-Kettering Cancer Center
关键词
3-DIMENSIONAL TREATMENT PLANNING; COMPENSATORS;
D O I
10.1118/1.596699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Presented here is a method of designing compensators for a single beam or one or more pairs of beams, not necessarily parallel opposed. The objective is to produce a flat distribution in a plane that may be perpendicular to the central ray or may be an arbitrarily oriented plane, for example, a plane that bisects the hinge angle between two beams. The method takes into account not only surface irregularities but also tissue inhomogeneities, hinge angles between beams, distance from the source, and even "horns" in the beam. The design process employs convolution of Monte Carlo generated pencil beams with photon fluence distributions, appropriately modified for the presence of beam modifiers (blocks and compensators), to compute dose in a flat homogeneous phantom. Corrections for inhomogeneities and surface curvature are applied by using computerized tomography information to determine the effective path length through tissue. Multiple interations are used to arrive at a compensator that properly incorporates changes in radiation transport, and therefore dose distribution, resulting from the presence of beam-shaping devices. In each iteration it is assumed that the required reduction in dose at a point can be achieved by reducing the fluence along the ray joining the source to computation point proportionately. The compensator design is represented as a finely spaced matrix of thickness values which is entered into a prorammable milling maching for fabrication. Dose measurements in phantom exposed to 6-MV x rays with and without compensation are presented.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [41] Diagnosis and treatment planning of orthodontic patients with 3-dimensional dentofacial records
    Manosudprasit, Amornrut
    Haghi, Arshan
    Allareddy, Veerasathpurush
    Masoud, Mohamed I.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (06) : 1083 - 1091
  • [42] 3-DIMENSIONAL (3D) TREATMENT PLANNING IN RADIOTHERAPY OF BRAIN-TUMORS
    BIDMEAD, AM
    KAUSHAL, V
    HILL, LJ
    BRADA, M
    BRITISH JOURNAL OF CANCER, 1990, 61 (01) : 161 - 161
  • [43] STANDARDIZED ADJUSTMENT AND DOSIMETRY IN TOTAL-BODY IRRADIATION WITH 3-DIMENSIONAL COMPENSATORS
    LEITNER, H
    STRAHLENTHERAPIE UND ONKOLOGIE, 1987, 163 (09): : 609 - 612
  • [44] Treatment of a severe transverse dental arch discrepancy assisted by 3-dimensional planning
    Chen, Si
    Xu, Tian-Min
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (01) : 105 - 115
  • [45] RADIOTOXIC MODEL FOR 3-DIMENSIONAL TREATMENT PLANNING .1. THEORETICAL BASIS
    CAUDRY, M
    CAUSSE, N
    TROUETTE, R
    RECALDINI, L
    MAIRE, JP
    DEMEAUX, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (05): : 907 - 919
  • [46] 3-DIMENSIONAL TREATMENT OF ADSORPTION
    BRUNET, J
    CHEMICAL ENGINEERING SCIENCE, 1972, 27 (04) : 685 - &
  • [47] DEVELOPMENT OF A SPECT-BASED 3-DIMENSIONAL TREATMENT PLANNING SYSTEM FOR RADIOIMMUNOTHERAPY
    GIAP, HB
    MACEY, DJ
    PODOLOFF, DA
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (10) : 1885 - 1894
  • [48] Comparative Analysis of 3-Dimensional Rotation Angiography versus 3-Dimensional Computed Tomography Angiography for Intracranial Aneurysm Treatment Detection and Planning
    Park, Jonathan
    Salamon, Noriko
    Duckwiler, Gary
    Vinuela, Fernando
    Sayer, James
    Villablanca, J. Pablo
    STROKE, 2013, 44 (02)
  • [49] COMPUTERIZED 3-DIMENSIONAL TREATMENT PLANNING SYSTEM UTILIZING INTERACTIVE COLOR GRAPHICS
    MCSHAN, DL
    SILVERMAN, A
    LANZA, DM
    REINSTEIN, LE
    GLICKSMAN, AS
    BRITISH JOURNAL OF RADIOLOGY, 1979, 52 (618): : 478 - 481