Intradialytic hypoxemia was studied via continuous, in-line monitoring of oxygen saturation (O-2 Sat) in 16 patients during six independent 3- to 4-hour dialysis sessions (three patient treatments were aborted). The results of 93 runs showed a mean decrease in O-2 Sat from pre- to post-dialysis of -1.4%. No significant change in O-2 Sat was observed during the occurrence of morbid events such as hypotension, cramping, or lightheadedness. Twenty-six percent (24/93) of the treatment sessions showed a 2-8% decrease in O-2 Sat during the first hour of dialysis. Fifty-six percent (9 of 16 patients) experienced at least one episode of hypoxemia (defined as O-2 Sat <90% during 51 of the 93 treatments. Two of the 16 patients exhibited intradialytic sleep apnea, and two others with chronic obstructive pulmonary disease (COPD) exhibited O-2 Sat levels between 77 and 89% during dialysis. Since the continuous, in-line O-2 Sat monitor is insensitive to poor skin perfusion, it is not affected by hypotension, multiple previous shunts, low body temperature, and other dialysis-related factors that cause errors in pulse oximeters. Continuous, in-line monitoring of O-2 Sat could prove to be useful in identifying the underlying mechanisms ofhypoxemia, and in diagnosing and treating sleep apnea, COPD, pulmonary edema, and other complications
引用
收藏
页码:615 / &
相关论文
共 50 条
  • [31] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION DURING AORTIC-SURGERY
    SHENAQ, SA
    CASAR, G
    CHELLY, JE
    OTT, H
    CRAWFORD, ES
    CHEST, 1987, 92 (05) : 796 - 799
  • [32] CONTINUOUS INTRAPARTUM MEASUREMENT OF FETAL OXYGEN-SATURATION
    JOHNSON, N
    LILFORD, RJ
    LANCET, 1988, 2 (8609): : 517 - 517
  • [33] CONTINUOUS INTRAPARTUM MEASUREMENT OF FETAL OXYGEN-SATURATION
    PEAT, S
    BOOKER, M
    LANIGAN, C
    PONTE, J
    LANCET, 1988, 2 (8604): : 213 - 213
  • [34] THE CONTINUOUS MEASUREMENT OF MIXED VENOUS OXYGEN-SATURATION
    HARPIN, RP
    DOWNER, JP
    CHEST, 1985, 87 (06) : 845 - 845
  • [35] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION DURING ANESTHESIA FOR PULMONARY SURGERY
    SAFRAN, D
    JOURNOIS, D
    HUBSCH, JP
    CASTELAIN, MH
    BARRIER, G
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1989, 8 (06): : 682 - 687
  • [36] POSTOPERATIVE MIXED VENOUS OXYGEN-SATURATION MONITORING
    BARON, JF
    BENSOUDA, A
    CORIAT, P
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1988, 2 (04): : 327 - 332
  • [37] MONITORING OF CENTRAL VENOUS OXYGEN-SATURATION VERSUS MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    MARTIN, C
    AUFFRAY, JP
    BADETTI, C
    PERRIN, G
    PAPAZIAN, L
    GOUIN, F
    INTENSIVE CARE MEDICINE, 1992, 18 (02) : 101 - 104
  • [38] SPECTROPHOTOMETRIC MONITORING OF ARTERIAL OXYGEN-SATURATION IN THE FINGERTIP
    YOSHIYA, I
    SHIMADA, Y
    TANAKA, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (01) : 27 - 32
  • [39] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [40] JUGULAR VENOUS OXYGEN-SATURATION MONITORING - REPLY
    ROBERTSON, CS
    JOURNAL OF NEUROSURGERY, 1992, 77 (01) : 163 - 163