Pinhole transmission grating spectrometer of X-ray picosecond frame

被引:0
|
作者
Jinxiu Cheng
Tianshu Wen
Cunbang Yang
Zhijian Zheng
Jiabin Chen
Shuping Liu
Shaojun Fu
Yiling Hong
机构
[1] Chinese Academy of Engineeing Physics,Laboratory for Laser Fusion Institute of Nuclear Physics and Chemistry
[2] University of Science and Technology of China,International Synchronicity Irradiation Laboratory
来源
关键词
laser-produced plasma; three-dimensional resolution; combination’s diagnostic;
D O I
暂无
中图分类号
学科分类号
摘要
The structure principle and performance of the measure system of three-dimensional resolution of time, space and spectrum for laser-produced plasma are presented. The typical experimental results are also given.
引用
收藏
页码:546 / 550
页数:4
相关论文
共 50 条
  • [21] X-ray calibration of the AXAF low energy transmission grating spectrometer: Effective area
    Predehl, P
    Brauninger, H
    Brinkman, AC
    Dewey, D
    Drake, JJ
    Flanagan, KA
    Gunsing, T
    Hartner, GD
    Juda, JHZ
    Juda, M
    Kaastra, J
    Marshall, HL
    Swartz, D
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 172 - 180
  • [22] 4-CHANNEL X-RAY SPECTROMETER ON A TRANSMISSION GRATING WITH A COMBINED SYSTEM OF DETECTION
    ALEXANDROV, YM
    KOSHEVOI, MO
    MURASHOVA, VA
    NIKITINA, TF
    RUPASOV, AA
    SHIKANOV, AS
    SKLIZKOV, GV
    YAKIMENKO, MN
    ZAKHARENKOV, YA
    EIDMAN, K
    SIGEL, R
    TSAKIRIS, GD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2247 - 2248
  • [23] Design of a transmission grating spectrometer and an undulator beamline for soft x-ray emission studies
    Hatsui, T
    Shigemasa, E
    Kosugi, N
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 921 - 924
  • [24] Space-Resolved Spectrum Diagnose by Soft X-Ray Transmission Grating Spectrometer
    尚万里
    赵阳
    熊刚
    杨家敏
    朱托
    Plasma Science and Technology, 2011, 13 (01) : 36 - 39
  • [25] Development of a critical-angle transmission grating spectrometer for the International X-Ray Observatory
    Heilmann, Ralf K.
    Ahn, Minseung
    Bautz, Mark W.
    Foster, Rick
    Huenemoerder, David P.
    Marshall, Herman L.
    Mukherjee, Pran
    Schattenburg, Mark L.
    Schulz, Norbert S.
    Smith, Matthew
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY IV, 2009, 7437
  • [26] Calibration of charge coupled devices and a pinhole transmission grating to be used as elements of a soft x-ray spectrograph
    Schriever, G
    Lebert, R
    Naweed, A
    Mager, S
    Neff, W
    Kraft, S
    Scholze, F
    Ulm, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (09): : 3301 - 3306
  • [27] Water Recovery X-Ray Rocket grating spectrometer
    Miles, Drew M.
    Hull, Samuel, V
    Schultz, Ted B.
    Tutt, James
    Wages, Mitchell
    Donovan, Benjamin
    Mcentaffer, Randall L.
    Falcone, Abraham D.
    Anderson, Tyler
    Bray, Evan
    Burrows, David N.
    Chattopadhyay, Tanmoy
    Eichfeld, C. M.
    Empson, Nathan
    Grise, Fabien
    Hillman, Christopher R.
    McCoy, Jake A.
    McQuaide, Maria
    Myers, Bailey J.
    Steiner, Tyler
    Verschuuren, Marc A.
    Yastishock, Daniel
    Zhang, Ningxiao
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2019, 5 (04)
  • [28] SOURCE SCANNING TYPE X-RAY GRATING SPECTROMETER
    SAWADA, M
    TSUTSUMI, K
    JOURNAL OF APPLIED PHYSICS, 1969, 40 (04) : 1950 - &
  • [29] Off-Plane X-ray Grating Spectrometer for the International X-ray Observatory
    McEntaffer, Randall L.
    Murray, Neil J.
    Holland, Andrew
    Lillie, Chuck
    Casement, Suzanne
    Dailey, Dean
    Johnson, Tim
    Cash, Webster
    Oakley, Phil
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE, 2009, 7360
  • [30] Soft X-ray response of a CCD with a grating spectrometer
    Shouho, M
    Katayama, K
    Katayama, H
    Kohmura, T
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Hashimotodani, K
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 85 - 90