Preconcentration of trace elements in sea water with poly (acrylaminophosphonic – dithiocarbamate) chelating fiber for their determination by inductively coupled plasma mass spectrometry

被引:0
|
作者
B. Wen
X.-Q. Shan
Rui-Xia Liu
Hong-Xiao Tang
机构
[1] Research Center for Eco-Environmental Sciences,
[2] Chinese Acadamy of Sciences,undefined
[3] P.O.Box 2871,undefined
[4] Beijing 100085,undefined
[5] China e-mail: Xiaoquan@mail.rcees.ac.cn,undefined
关键词
Cobalt; Bismuth; Gallium; Inductively Couple Plasma Mass Spectrometry; Beryllium;
D O I
暂无
中图分类号
学科分类号
摘要
A new ion exchange chelating fiber with aminophosphonic and dithiocarbamate groups based on polyacrylonitrile was used for the simultaneous preconcentration of beryllium, bismuth, cobalt, gallium, silver, lead, cadium, copper, manganese and indium in sea water. The optimum experimental parameters, such as fiber capacity, pH, sample flow rate and volume, eluant and effect of matrix ions on the preconcentration were investigated. The separation of analytes can be achieved from sea water with a concentration factor of at least 200 times. The method has been applied for the determination of trace elements in coastal sea water. The data obtained by this method agreed well with certified values.
引用
收藏
页码:251 / 255
页数:4
相关论文
共 50 条
  • [21] Determination of trace elements in brown coals by inductively coupled plasma mass spectrometry
    Oleinikova, G. A.
    Kudryashov, V. L.
    Vyalov, V. I.
    Fadin, Ya. Yu.
    SOLID FUEL CHEMISTRY, 2015, 49 (02) : 109 - 116
  • [22] The determination of trace metal elements in diesel by inductively coupled plasma mass spectrometry
    Department of Material and Chemical Engineering, Hunan Institute of Technology, Hengyang
    421002, China
    不详
    408100, China
    不详
    410208, China
    Shiyou Xuebao Shiyou Jiagong, 4 (972-977):
  • [23] Multielement determination of trace metals in seawater by inductively coupled plasma mass spectrometry after tandem preconcentration using a chelating resin
    Zhu, Y
    Itoh, A
    Fujimori, E
    Umemura, T
    Haraguchi, H
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2005, 78 (04) : 659 - 667
  • [24] Preconcentration and determination of trace metals in seawater using a thiol cotton fiber minicolumn coupled with inductively coupled plasma mass spectrometry
    Zhang, SZ
    Lu, AX
    Han, F
    Shan, XQ
    ANALYTICAL SCIENCES, 2005, 21 (06) : 651 - 654
  • [25] Preconcentration and Determination of Trace Metals in Seawater Using a Thiol Cotton Fiber Minicolumn Coupled with Inductively Coupled Plasma Mass Spectrometry
    Shuzhen Zhang
    Anxiang Lu
    Fang Han
    Xiao-quan Shan
    Analytical Sciences, 2005, 21 : 651 - 654
  • [26] Automated on-line preconcentration for trace metals determination in water samples by inductively coupled plasma mass spectrometry
    Packer, AP
    Gine, MF
    Miranda, CES
    DosReis, BF
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (05) : 563 - 566
  • [27] Multi-elemental determination of trace elements in deep seawater by inductively coupled plasma mass spectrometry with resin preconcentration
    Sumida, T
    Nakazato, T
    Tao, H
    BUNSEKI KAGAKU, 2003, 52 (08) : 619 - 626
  • [28] Determination of rare earth elements in human blood serum by inductively coupled plasma mass spectrometry after chelating resin preconcentration
    Inagaki, K
    Haraguchi, H
    ANALYST, 2000, 125 (01) : 191 - 196
  • [29] Determination of rare earth elements in blood serum reference sample by chelating resin preconcentration and inductively coupled plasma mass spectrometry
    Fujimori, E
    Tomosue, Y
    Haraguchi, H
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1996, 178 (01): : 63 - 74
  • [30] DETERMINATION OF TRACE-ELEMENTS IN SEA-WATER BY ION CHROMATOGRAPHY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    BETTINELLI, M
    SPEZIA, S
    JOURNAL OF CHROMATOGRAPHY A, 1995, 709 (02) : 275 - 281