Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale

被引:0
|
作者
Jiang-Chun He
Jian-Yong Zheng
Xin Li
Ye Yang
Bo-Yang Zhang
Yu Chen
Xian-Feng Li
Ying-Ming Liu
Yi Cao
Li Zhao
Tian-Chang Li
机构
[1] Navy General Hospital of PLA,Department of Cardiology
[2] Navy General Hospital of PLA,Department of Ultrasound
来源
The International Journal of Cardiovascular Imaging | 2017年 / 33卷
关键词
Transthoracic contrast echocardiography; Transesophageal echocardiography; Patent foramen ovale; Vitamin B6; Sodium bicarbonate;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ2=5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=−2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.
引用
收藏
页码:1125 / 1131
页数:6
相关论文
共 50 条
  • [41] Enhanced detection of right-to-left shunt through patent foramen ovale by transthoracic contrast echocardiography using harmonic imaging
    Ha, JW
    Shin, MS
    Kang, S
    Pyun, WB
    Jang, KJ
    Byun, KH
    Rim, SJ
    Huh, J
    Lee, BI
    Chung, N
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (05): : 669 - 671
  • [42] A two-step deep learning approach for patent foramen ovale diagnosis based on spatiotemporal sequence information of contrast transthoracic echocardiography
    Gu, Mengjie
    Liu, Yingying
    Wang, Lin
    Sheng, Yuanyuan
    Zhu, Junlong
    Yan, Junqiang
    Zhang, Mingchuan
    Wu, Qingtao
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 107
  • [43] Comparative diagnostic accuracy of transcranial Doppler and contrast-enhanced transthoracic echocardiography for the diagnosis of patent foramen ovale and atrial septal defect
    Lanzone, Alberto M.
    Castelluccio, Emanuele, V
    della Pina, Paolo
    Boldi, Emiliano
    Lussardi, Gianluca
    Frati, Giacomo
    Gaudio, Carlo
    Biondi-Zoccai, Giuseppe
    PANMINERVA MEDICA, 2024,
  • [44] Saline Contrast Echocardiography for the Detection of Patent Foramen Ovale in Hypoxia: A Validation Study Using Intracardiac Echocardiography
    Fenster, Brett E.
    Curran-Everett, Douglas
    Freeman, Andrew M.
    Weinberger, Howard D.
    Buckner, J. Kern
    Carroll, John D.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (04): : 420 - 427
  • [45] Contrast transoesophageal echocardiography remains superior to contrast-enhanced cardiac magnetic resonance imaging for the diagnosis of patent foramen ovale
    Hamilton-Craig, C.
    Sestito, A.
    Natale, L.
    Meduri, A.
    Santangeli, P.
    Infusino, F.
    Pilato, F.
    Di Lazzaro, V.
    Crea, F.
    Lanza, G. A.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (03): : 222 - 227
  • [46] A score of non-contrast transthoracic echocardiography to screen patent foramen ovale in patients with embolic stroke of undetermined source
    Zhang, Hui
    Tang, Haiyan
    Wu, Fei
    Yu, Chun
    Dong, Qiang
    Cao, Wenjie
    BMC NEUROLOGY, 2022, 22 (01)
  • [47] A score of non-contrast transthoracic echocardiography to screen patent foramen ovale in patients with embolic stroke of undetermined source
    Hui Zhang
    Haiyan Tang
    Fei Wu
    Chun Yu
    Qiang Dong
    Wenjie Cao
    BMC Neurology, 22
  • [48] Sensitivity of contrast-enhanced transthoracic echocardiography for the detection of residual shunts after percutaneous patent foramen ovale closure
    Zhao, Hongling
    Yue, Qingxiong
    Wang, Tao
    Wang, Lin
    Pang, Zhanqi
    Dong, He
    Yang, Jian
    Li, Yawen
    Li, Shijun
    MEDICINE, 2019, 98 (04)
  • [49] Exercise treadmill saline contrast echocardiography for the detection of patent foramen ovale in hypoxia
    Brett E. Fenster
    Andrew M. Freeman
    Lori Silveira
    J. Kern Buckner
    Douglas Curran-Everett
    John D. Carroll
    The International Journal of Cardiovascular Imaging, 2015, 31 : 1537 - 1543
  • [50] Exercise treadmill saline contrast echocardiography for the detection of patent foramen ovale in hypoxia
    Fenster, Brett E.
    Freeman, Andrew M.
    Silveira, Lori
    Buckner, J. Kern
    Curran-Everett, Douglas
    Carroll, John D.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (08): : 1537 - 1543