Transforming Method of TLCD-structure to TMD-structure for Vibration Control

被引:0
|
作者
Chuan Fu
机构
[1] North China University of Technology,School of Civil Engineering
来源
关键词
tuned liquid column damper; tuned mass damper; optimal parameter; modal tuning; numerical simulation;
D O I
暂无
中图分类号
学科分类号
摘要
Tuned Liquid Column Damper (TLCD) relies on the motion of a liquid mass in an open tube counteract the external motion, while a built-in orifice plate induces turbulent damping forces that dissipate kinetic energy. Although both the construction and working principle of TLCD differ from Tuned Mass Damper (TMD), the analogies between TLCD-structure and TMD-structure system for symmetric and asymmetric structures are given. The mass ratio, the optimal frequency ratio, the natural frequency and damping of the main structure, etc are achieved. Modal tuning of the TLCD, frequency ratio and damping, is classically done by applying the Den Hartog optimization criterion. The analysis of structural vibration control using finite element software is presented. Numerical simulations of the four-storey asymmetric structure and 20-storey benchmark model with single TLCD or TLCDs with the parameters using Den Hartog formula and structural analysis by SAP 2000 software show that the method of transforming TLCD-structure to TMD-structure system is reasonable and feasible.
引用
收藏
页码:1384 / 1393
页数:9
相关论文
共 50 条
  • [41] The Study on Building Structure for Vibration Control
    Li, Longjiang
    MECHATRONICS AND INTELLIGENT MATERIALS II, PTS 1-6, 2012, 490-495 : 2714 - 2718
  • [42] Distributed vibration control of tensegrity structure
    Li, Tuanjie
    Wang, Zuowei
    Li, Jin
    Ma, Yujuan
    JOURNAL OF VIBRATION AND CONTROL, 2013, 19 (05) : 720 - 728
  • [43] Motion and vibration control of a flexible structure
    De Fonseca, P.
    Van Brussel, H.
    Sas, P.
    2000, Sage Sci Press, Thousand Oaks, CA, United States (32):
  • [44] A model test study on controlling vibration of an elevated track box girder structure with TMD
    Zhang X.
    Lei X.
    Luo K.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2021, 40 (16): : 220 - 226and233
  • [45] The Control Effect Analysis of the Variable Frequency TMD Applied to the Frame Structure
    Zhang Maoyu
    Li Bo
    Wang Yanru
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 3486 - 3489
  • [46] Active Vibration Control of Wind Turbine Using Virtual TMD Algorithm Based on Aerodynamic-Structure-Servo Coupling Model
    Long, Tao
    Yang, Qingshan
    Wang, Qi
    Huang, Guoqing
    Zhou, Xuhong
    Yang, Yu
    STRUCTURAL CONTROL & HEALTH MONITORING, 2023, 2023
  • [47] Variable structure control of vibration isolation systems based on Arckermann's method
    Pan, SW
    Hu, XH
    Pan, JQ
    PROCEEDINGS OF THE 3RD WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-5, 2000, : 3005 - 3008
  • [48] A variable-structure control method for the suppression of elevator-cage vibration
    Arakawa, A
    Miyata, K
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 1830 - 1835
  • [49] Performance of a Magneto-Rheological Tuned Liquid Column Damper (MR-TLCD) in Mitigating Vibration of an Offshore Structure
    Mohammadyzadeh, Samira
    Mojtahedi, Alireza
    Hokmabady, Hamid
    Farajpour, Ismail
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2022, 10 (08) : 2999 - 3010
  • [50] Vibration control of an eleven-story structure with MR and TMD dampers using MAC predictive control, considering nonlinear behavior and time delay in the control system
    Bathaei, Akbar
    Zahrai, Seyed Mehdi
    STRUCTURES, 2024, 60