Transforming Method of TLCD-structure to TMD-structure for Vibration Control

被引:0
|
作者
Chuan Fu
机构
[1] North China University of Technology,School of Civil Engineering
来源
关键词
tuned liquid column damper; tuned mass damper; optimal parameter; modal tuning; numerical simulation;
D O I
暂无
中图分类号
学科分类号
摘要
Tuned Liquid Column Damper (TLCD) relies on the motion of a liquid mass in an open tube counteract the external motion, while a built-in orifice plate induces turbulent damping forces that dissipate kinetic energy. Although both the construction and working principle of TLCD differ from Tuned Mass Damper (TMD), the analogies between TLCD-structure and TMD-structure system for symmetric and asymmetric structures are given. The mass ratio, the optimal frequency ratio, the natural frequency and damping of the main structure, etc are achieved. Modal tuning of the TLCD, frequency ratio and damping, is classically done by applying the Den Hartog optimization criterion. The analysis of structural vibration control using finite element software is presented. Numerical simulations of the four-storey asymmetric structure and 20-storey benchmark model with single TLCD or TLCDs with the parameters using Den Hartog formula and structural analysis by SAP 2000 software show that the method of transforming TLCD-structure to TMD-structure system is reasonable and feasible.
引用
收藏
页码:1384 / 1393
页数:9
相关论文
共 50 条
  • [1] Transforming Method of TLCD-structure to TMD-structure for Vibration Control
    Fu, Chuan
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (04) : 1384 - 1393
  • [2] An equivalent calculation method for analysis of structural vibration control of transforming TLD-structure to TMD-structure system
    Liu, Guo-Huan
    Li, Hong-Nan
    Guo, Wei
    Gongcheng Lixue/Engineering Mechanics, 2011, 28 (05): : 31 - 34
  • [3] CFD/CSD coupled analysis method for wind-induced vibration responses of TLCD-structure system
    Huang, Peng
    Wu, Jiurong
    Fu, Jiyang
    Sun, Hanyang
    Wang, Jialei
    Zhendong yu Chongji/Journal of Vibration and Shock, 2024, 43 (11):
  • [5] Vibration Control of TLCD-Base Isolated Frame Structure
    Fu C.
    Xiao Y.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2020, 40 (04): : 788 - 793
  • [6] Effects of TLCD with maneuverable flaps on vibration control of a SDOF structure
    Hamid Pesaran Behbahani
    Azlan bin Adnan
    Mohammadreza Vafaei
    Ong Peng Pheng
    Hossein Shad
    Meccanica, 2017, 52 : 1247 - 1256
  • [7] Effects of TLCD with maneuverable flaps on vibration control of a SDOF structure
    Behbahani, Hamid Pesaran
    bin Adnan, Azlan
    Vafaei, Mohammadreza
    Pheng, Ong Peng
    Shad, Hossein
    MECCANICA, 2017, 52 (06) : 1247 - 1256
  • [8] Energy analysis for TMD-structure systems subjected to impact loading
    Wang, SQ
    Li, HJ
    Ji, CY
    Jiao, GY
    CHINA OCEAN ENGINEERING, 2002, 16 (03) : 301 - 310
  • [9] Energy Anaiysis for TMD-Structure Systems Subjected to Impact Loading
    王树青
    李华军
    嵇春艳
    焦桂英
    ChinaOceanEngineering, 2002, (03) : 301 - 310
  • [10] Vibration control of TLCD-eccentric base isolated structure under seismic excitation
    Chuan, Fu
    STRUCTURES, 2025, 73