Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging

被引:0
|
作者
Jeong Hee Yoon
Jeong Min Lee
Munyoung Paek
Joon Koo Han
Byung Ihn Choi
机构
[1] Seoul National University Hospital,Department of Radiology
[2] Seoul National University College of Medicine,Institute of Radiation Medicine
[3] Siemens Healthcare,undefined
来源
European Radiology | 2016年 / 26卷
关键词
T1 map; Gadoxetic acid; Magnetic resonance imaging; MOLLI; Liver function estimation;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1775 / 1782
页数:7
相关论文
共 50 条
  • [21] Quantitative assessment of hepatic fibrosis in chronic hepatitis B and C: T1 mapping on Gd-EOB-DTPA-enhanced liver magnetic resonance imaging
    Shen Pan
    Xiao-Qi Wang
    Qi-yong Guo
    World Journal of Gastroenterology, 2018, (18) : 2024 - 2035
  • [22] Usefulness of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging in assessment of non-alcoholic fatty liver disease
    Ying Ding
    Sheng-Xiang Rao
    Tao Meng
    Caizhong Chen
    Renchen Li
    Meng-Su Zeng
    European Radiology, 2014, 24 : 959 - 966
  • [23] Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart
    Messroghli, Daniel R.
    Greiser, Andreas
    Froehlich, Mirko
    Dietz, Rainer
    Schulz-Menger, Jeanette
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1081 - 1086
  • [24] Assessment of liver fibrosis using T1 mapping on Gd-EOB-DTPA-enhanced magnetic resonance
    Sheng, Ruo Fan
    Wang, He Qing
    Yang, Li
    Jin, Kai Pu
    Xie, Yan Hong
    Fu, Cai Xia
    Zeng, Meng Su
    DIGESTIVE AND LIVER DISEASE, 2017, 49 (07) : 789 - 795
  • [25] Temporal registration: a new approach to manage the incomplete recovery of the longitudinal magnetization in the Modified Look-Locker Inversion Recovery sequence (MOLLI) for T1 mapping of the heart
    Habib Rebbah
    Thierry Galas
    Gilles Soulat
    Nadjia Kachenoura
    Anne Menini
    Charles A. Cuenod
    Elie Mousseaux
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 569 - 580
  • [26] Accuracy, Precision, and Reproducibility of Myocardial T1 Mapping: A Comparison of Four T1 Estimation Algorithms for Modified Look-Locker Inversion Recovery (MOLLI)
    Shao, Jiaxin
    Liu, Dapeng
    Sung, Kyunghyun
    Kim-Lien Nguyen
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1746 - 1756
  • [27] Influence of Fat on Liver T1 Measurements Using Modified Look-Locker Inversion Recovery (MOLLI) Methods at 3T
    Mozes, Ferenc E.
    Tunnicliffe, Elizabeth M.
    Pavlides, Michael
    Robson, Matthew D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 105 - 111
  • [28] Assessing liver function in patients with HBV-related HCC: a comparison of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI
    Ding, Ying
    Rao, Sheng-Xiang
    Chen, Caizhong
    Li, Renchen
    Zeng, Meng-Su
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1392 - 1398
  • [29] Assessing liver function in patients with HBV-related HCC: a comparison of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI
    Ying Ding
    Sheng-Xiang Rao
    Caizhong Chen
    Renchen Li
    Meng-Su Zeng
    European Radiology, 2015, 25 : 1392 - 1398
  • [30] Validation of the shortened modified look locker inversion recovery (Sh-MOLLI) sequence for cardiac gated T1 mapping
    Piechnik S.K.
    Ferreira V.M.
    Dall'Armellina E.
    Neubauer S.
    Robson M.D.
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)