Flow-Injection Electrogenerated Chemiluminescence Determination of Isoniazid Using Luminol

被引:0
|
作者
Xingwang Zheng
Zhihui Guo
Zhujun Zhang
机构
[1] Shaanxi Normal University,Department of Chemistry
来源
Analytical Sciences | 2001年 / 17卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Based on a new electrogenerated chemiluminescence (ECL) analytical idea, this paper explains a sensitive and selective flow-injection ECL method using luminol for the determination of isoniazid, based on the sensitizing effect of isoniazid for the weak ECL emission of electrochemically oxidized luminol. Under the optimum experimental conditions, the relative ECL intensity was linear with isoniazid concentration in the range of 4.0 × 10–8 mol/L to 8.0 × 10–6 mol/L and with a detecting limit of 2.8 × 10–8 mol/L.
引用
收藏
页码:1095 / 1099
页数:4
相关论文
共 50 条
  • [21] Flow-injection chemiluminescence determination of hydrazine using on-line electrogenerated BrO- as the oxidant
    Li, BX
    Zhang, ZJ
    Zheng, XW
    Xu, CL
    CHEMIA ANALITYCZNA, 2000, 45 (05): : 709 - 717
  • [22] Determination of epinephrine by flow-injection analysis using luminol-hexacyanoferrate(III) chemiluminescence detection
    Kojlo, A
    Nalewajko, E
    CHEMIA ANALITYCZNA, 2004, 49 (05): : 653 - 663
  • [23] Flow-injection chemiluminescence determination of captopril using on-line electrogenerated silver(II) as the oxidant
    Li, BX
    Zhang, ZJ
    Wu, ML
    MICROCHEMICAL JOURNAL, 2001, 70 (02) : 85 - 91
  • [24] Flow-injection chemiluminescence determination of sulfite using on-line electrogenerated silver(II) as the oxidant
    Li, BX
    Zhang, ZJ
    Wu, ML
    ANALYTICA CHIMICA ACTA, 2001, 432 (02) : 311 - 316
  • [25] Flow-injection chemiluminescence determination of dihydralazine sulfate in serum using luminol and diperiodatocuprate (III) system
    Yang, Chunyan
    Zhang, Zhujun
    Wang, Jinli
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2010, 75 (01) : 77 - 82
  • [26] Flow-injection electrogenerated chemiluminescence determination of fluoroquinolones based on its sensitizing effect
    Ma, HY
    Zheng, XW
    Zhang, ZJ
    LUMINESCENCE, 2005, 20 (4-5) : 303 - 306
  • [27] FLOW-INJECTION ANALYSIS FOR DETERMINATION OF CHOLINE-CONTAINING PHOSPHOLIPIDS BY LUMINOL CHEMILUMINESCENCE
    MATSUBARA, C
    ISHII, K
    TAKAMURA, K
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1992, 112 (01): : 50 - 55
  • [28] Flow-injection chemiluminescence determination of thiamine by enhancement of the luminol-ferricyanide system
    Li, Y.
    Yang, Y.
    Lu, J.
    LUMINESCENCE, 2008, 23 (02) : 81 - 81
  • [29] Flow-injection chemiluminescence determination of polyphenols using luminol-NaIO4-gold nanoparticles system
    Li, Shifeng
    Li, Xiangzi
    Xu, Jing
    Wei, Xianwen
    TALANTA, 2008, 75 (01) : 32 - 37
  • [30] A novel enhancing flow-injection chemiluminescence method for the determination of glutathione using the reaction of luminol with hydrogen peroxide
    Wang, L
    Li, YX
    Zhao, DH
    Zhu, CQ
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 41 - 45