Long-term durability of orthodontic mini-implants

被引:0
|
作者
Mona Aly Abbassy
Ahmed Samir Bakry
Khalid Hashim Zawawi
Ali Habib Hassan
机构
[1] King Abdulaziz University,Department of Orthodontics, Faculty of Dentistry
[2] Alexandria University,Operative Dentistry Department, Faculty of Dentistry
[3] King Abdulaziz University,Conservative Dentistry Department, Faculty of Dentistry
[4] Alexandria University,undefined
来源
Odontology | 2018年 / 106卷
关键词
Mini-implants; Orthodontics; Oral-care products; SEM-EDS;
D O I
暂无
中图分类号
学科分类号
摘要
The current study aimed at examining surface and chemical composition changes of retrieved mini-implants after different periods of service as aids of anchorage for orthodontic patients. This study examined 72 retrieved orthodontic self-tapping and self-drilling mini-implants, 1.7 mm in diameter and 8 mm in length (OrthoEasy system, Forestadent, Pforzheim, Germany) from 36 adult orthodontic patients (18 men and 18 women, mean age = 23 years). The retrieved mini-implants were divided into 3 groups according to service period: 3–6 months (3M–6M) group, 6–12 months (6M–12M) group, and 12–24 months (12M–24M) group, with 24 mini-implants in each group. The control group (As Received) comprised of 24 unused mini-implants of the same type (AR group). All mini-implant heads and threaded bodies were examined for chemical characterization and topographical features by SEM–EDS. The average weight percentages for the following elements Ti, Al, and O2 were obtained and compared among the 4 groups. There was significant decrease in titanium content and deterioration for the surface properties for all parts of the mini-implants after being used inside patients’ oral cavities for more than 6 months p < 0.05. The period of mini-implant service inside patients’ oral cavities should not exceed 6 months.
引用
收藏
页码:208 / 214
页数:6
相关论文
共 50 条
  • [31] Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Drescher, Dieter
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (04) : 396 - 401
  • [32] EVALUATION OF THE BIOMECHANICAL PROPERTIES OF IN VIVO USED ORTHODONTIC MINI-IMPLANTS
    Pop, Silvia Izabella
    Dudescu, Mircea
    Ana, Procopciuc
    Kerekes-Mathe, Bernadette-Evelyn
    Mitariu, Mihai
    Bud, Eugen
    Mitariu, Loredana
    Pacurar, Mariana
    Pop, Radu Vasile
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2024, 16 (01): : 238 - 245
  • [33] Surface Analysis of Orthodontic Mini-Implants after Their Clinical Use
    Ioana, Tamara Rahela
    Boeru, Filip George
    Antoniac, Iulian
    Mitrut, Ioana
    Staicu, Ionela Elisabeta
    Rauten, Anne Marie
    Uriciuc, Willi Andrei
    Manolea, Horia Octavian
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (09)
  • [34] Pullout strengths of orthodontic palatal mini-implants tested in vitro
    Wu, Ju-Hui
    Wang, Huang-Chi
    Chen, Chun-Ming
    Lu, Pei-Chen
    Lai, Sheng-Tsung
    Lee, Kun-Tsung
    Du, Je-Kang
    JOURNAL OF DENTAL SCIENCES, 2011, 6 (04) : 200 - 204
  • [35] Insertion torque and success of orthodontic mini-implants: A systematic review
    Reynders, Reint A. Meursinge
    Ronchi, Laura
    Ladu, Luisa
    van Etten-Jamaludin, Faridi
    Bipat, Shandra
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (05) : 596 - +
  • [36] Generic finite element models of orthodontic mini-implants: Are they reliable?
    Albogha, Mhd Hassan
    Takahashi, Ichiro
    JOURNAL OF BIOMECHANICS, 2015, 48 (14) : 3751 - 3756
  • [37] The most distal palatal ruga for placement of orthodontic mini-implants
    Hourfar, Jan
    Ludwig, Bjorn
    Bister, Dirk
    Braun, Anna
    Kanavakis, Georgios
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (04) : 373 - 378
  • [38] Insertion Angle Impact on Primary Stability of Orthodontic Mini-implants
    Wilmes, Benedict
    Su, Yu-Yu
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2008, 78 (06) : 1065 - 1070
  • [39] In vitro evaluation of insertion and removal torques of orthodontic mini-implants
    Pithon, M. M.
    Nojima, M. G.
    Nojima, L. I.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (01) : 80 - 85
  • [40] Effect of rotation bump on removal torque of orthodontic mini-implants
    Gansukh, Odontuya
    Jeong, Jong-Wha
    Kim, Jong-Wan
    Kim, Young-Kyun
    Lee, Jong-Ho
    Kim, Tae-Woo
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2013, 39 (06) : 269 - 273