摘要
Light’s polarisation contains information about its source and interactions, from distant stars to biological samples. Polarimeters can recover this information, but reliance on birefringent or rotating optical elements limits their wavelength range and stability. Here we present a static, single-shot polarimeter based on a Fresnel cone - the direct spatial analogue to the popular rotating quarter-wave plate approach. We measure the average angular accuracy to be 2.9° (3.6°) for elliptical (linear) polarization states across the visible spectrum, with the degree of polarisation determined to within 0.12 (0.08). Our broadband full Stokes polarimeter is robust, cost-effective, and could find applications in hyper-spectral polarimetry and scanning microscopy.
引用
收藏
相关论文
共 50 条
  • [21] Design of a Full Stokes Polarimeter for Chromospheric Measurements with SOLIS/VSM
    Gosain, S.
    Harvey, J. W.
    POLARIMETRY: FROM THE SUN TO STARS AND STELLAR ENVIRONMENTS, 2015, 10 (305): : 186 - 190
  • [22] Full Stokes polarimeter for characterization of fiber optic gyroscope coils
    Lompado, Arthur
    Reinhardt, John C.
    Heaton, L. Chris
    Williams, Jeff L.
    Ruffin, Paul B.
    OPTICS EXPRESS, 2009, 17 (10): : 8370 - 8381
  • [23] Optimization of Polarization-Camera-Based Full Stokes Polarimeter
    Li Haiyu
    Li Chao
    Li Xiaobo
    Wang Hui
    Hu Haofeng
    Liu Tiegen
    ACTA OPTICA SINICA, 2020, 40 (03)
  • [24] Optimal design for a broadband Stokes polarimeter of liquid crystal variable retarders
    Wu, Jiaxin
    Li, Yanqiu
    Ning, Tianlei
    Long, Chenhui
    Zhou, Guodong
    APPLIED OPTICS, 2022, 61 (25) : 7490 - 7497
  • [25] Signal, noise, and bias for a broadband, division-of-amplitude Stokes polarimeter
    Tyler, David W.
    Mudge, Jason D.
    OPTICS EXPRESS, 2010, 18 (17): : 18015 - 18034
  • [26] Stokes polarimeter for the measurement of full linearly Stokes parameters with immunity to Gaussian and Poisson noise
    Li, Siyuan
    Quan, Naicheng
    Zhang, Chunmin
    Mu, Tingkui
    Hu, Bingliang
    OPTIK, 2018, 175 : 8 - 16
  • [27] Video-rate full-Stokes imaging polarimeter using two polarization cameras
    Shibata, Shuhei
    Suzuki, Masayuki
    Hagen, Nathan
    Otani, Yukitoshi
    OPTICAL ENGINEERING, 2019, 58 (10)
  • [28] Target detection with a liquid-crystal-based passive Stokes polarimeter
    Goudail, F
    Terrier, P
    Takakura, Y
    Bigué, L
    Galland, F
    DeVlaminck, V
    APPLIED OPTICS, 2004, 43 (02) : 274 - 282
  • [29] A novel method for the design of a full Stokes polarimeter based on dielectric metasurfaces
    Liu, Jianying
    Zhang, Ran
    Fan, Yuanyi
    Cheng, Haoyuan
    Guan, Chuanlong
    Chu, Jinkui
    OPTIK, 2022, 261
  • [30] Photoelastic modulator-based broadband mid-infrared Stokes polarimeter
    FitzGerald, William R.
    Hore, Dennis K.
    JOURNAL OF MODERN OPTICS, 2018, 65 (01) : 75 - 84