Use of pulse pressure variation and stroke volume variation in spontaneously breathing patients to assess dynamic arterial elastance and to predict arterial pressure response to fluid administration

被引:0
|
作者
M Cecconi
MI Monge García
M Gracia Romero
J Mellinghoff
F Caliandro
RM Grounds
A Rhodes
机构
[1] St George's Hospital,
[2] St George's Healthcare NHS Trust and St George's University of London,undefined
来源
Critical Care | / 18卷 / Suppl 1期
关键词
Cardiac Output; Arterial Pressure; Mean Arterial Pressure; Arterial Blood Pressure; Fluid Administration;
D O I
10.1186/cc13341
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [41] Stroke Volume and Arterial Pressure Fluid Responsiveness in Patients With Elevated Stroke Volume Variation Undergoing Major Vascular Surgery: A Prospective Intervention Study
    Fischer, Arabella
    Menger, Johannes
    Mouhieddine, Mohamed
    Seidel, Mathias
    Edlinger-Stanger, Maximilian
    Bevilacqua, Michele
    Brugger, Jonas
    Hiesmayr, Michael
    Dworschak, Martin
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (03) : 407 - 414
  • [42] Stroke Volume Variation and Pulse Pressure Variation Are Not Useful for Predicting Fluid Responsiveness in Thoracic Surgery
    Jeong, Dae Myoung
    Ahn, Hyun Joo
    Park, Hyo Won
    Yang, Mikyung
    Kim, Jie Ae
    Park, Joohyun
    ANESTHESIA AND ANALGESIA, 2017, 125 (04): : 1158 - 1165
  • [43] Assessment of Stroke Volume Variation Perioperatively by Using Arterial Pressure with Cardiac Output
    Wen-jing Li
    Yi-ping Hu
    Min-min Zhu
    Chinese Medical Sciences Journal, 2015, 30 (02) : 95 - 99
  • [44] Dynamic arterial elastance measured by uncalibrated pulse contour analysis predicts arterial-pressure response to a decrease in norepinephrine
    Bar, S.
    Leviel, F.
    Abou Arab, O.
    Badoux, L.
    Mahjoub, Y.
    Dupont, H.
    Lorne, E.
    Guinot, P. -G.
    BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (03) : 534 - 540
  • [45] PULSE PRESSURE AND STROKE VOLUME VARIATION ARE GOOD PREDICTORS OF FLUID RESPONSIVENESS IN SEVERE SEPSIS PATIENTS
    Drvar, Z.
    Baronica, R.
    Tomasevic, B.
    Pavlek, M.
    Miric, M.
    Peric, M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S202 - S202
  • [46] Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease
    Kim, So Yeon
    Song, Young
    Shim, Jae Kwang
    Kwak, Young Lan
    JOURNAL OF CRITICAL CARE, 2013, 28 (03) : 318.e1 - 318.e7
  • [47] Using pulse pressure variation or stroke volume variation to diagnose right ventricular failure? response
    Jakob, Stephan M.
    Takala, Jukka
    CRITICAL CARE, 2010, 14 (06):
  • [48] The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation
    Myatra, Sheila Nainan
    Prabu, Natesh R.
    Vasishtha, Jigeeshu
    Monnet, Xavier
    Kulkarni, Atul Prabhakar
    Teboul, Jean-Louis
    CRITICAL CARE MEDICINE, 2017, 45 (03) : 415 - 421
  • [49] Echocardiographic measure of dynamic arterial elastance predict pressure response during norepinephrine weaning: an observational study
    Nguyen, Maxime
    Abou-Arab, Osama
    Bar, Stephane
    Dupont, Herve
    Bouhemad, Belaid
    Guinot, Pierre-Gregoire
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [50] Echocardiographic measure of dynamic arterial elastance predict pressure response during norepinephrine weaning: an observational study
    Maxime Nguyen
    Osama Abou-Arab
    Stéphane Bar
    Hervé Dupont
    Bélaïd Bouhemad
    Pierre-Grégoire Guinot
    Scientific Reports, 11