Regional survey of image quality and radiation dose in computed tomography examinations in Saudi Arabia

被引:0
|
作者
M. K. Saeed
A. S. Alzoubi
J. M. Al-Qahtani
机构
[1] Najran University,Department of Radiological Sciences
[2] Najran University,College of Medicine
关键词
CT; Image quality; CTDI; Fabricated Phantom;
D O I
暂无
中图分类号
学科分类号
摘要
This study is the first regional investigation in Najran, Saudi Arabia aimed at investigating radiation dose and image quality of computed tomography (CT) examinations. The survey data was collected from five scanners in four hospitals. For all CT scanners, a correction factor was calculated to measure the weighted computed tomography dose index (CTDIw\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_{w}$$\end{document}) using standard dosimetry phantoms. The CTDIw\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_{w}$$\end{document} were reported in this study and compared with other countries. It was found that most CTDIw\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_{w}$$\end{document} values were close to the European reference levels and in line with the results of similar surveys in the other parts of world. Concerning image quality, 80 % of the scanners were found to be in compliance with the relative international guidelines for all the examined parameters
引用
收藏
页码:279 / 283
页数:4
相关论文
共 50 条
  • [31] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [32] Analysis of Radiation Dose to Pediatric Patients During Computed Tomography Examinations
    Kharbanda, Anupam B.
    Krause, Ernest
    Lu, Yi
    Blumberg, Karen
    ACADEMIC EMERGENCY MEDICINE, 2015, 22 (06) : 670 - 675
  • [33] Changing Radiation Dose From Diagnostic Computed Tomography Examinations in Saskatchewan
    Dumaine, Chance S.
    Leswick, David A.
    Fladeland, Derek A.
    Lim, Hyun J.
    Toews, Lori J.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2012, 63 (03): : 183 - 191
  • [34] Radiation dose of chaperones during common pediatric computed tomography examinations
    Overhoff, Daniel
    Weis, Meike
    Riffel, Philipp
    Sudarski, Sonja
    Froelich, Matthias F.
    Fries, Peter
    Schoenberg, Stefan
    Gawlitza, Joshua
    PEDIATRIC RADIOLOGY, 2020, 50 (08) : 1078 - 1082
  • [35] Radiation dose of chaperones during common pediatric computed tomography examinations
    Daniel Overhoff
    Meike Weis
    Philipp Riffel
    Sonja Sudarski
    Matthias F. Froelich
    Peter Fries
    Stefan Schönberg
    Joshua Gawlitza
    Pediatric Radiology, 2020, 50 : 1078 - 1082
  • [36] Evaluation of pediatric radiation doses in computed tomography procedures in the Kingdom of Saudi Arabia
    Alzimami, K.
    Sulieman, A.
    Omer, Hiba
    Jambi, Layal K.
    Alfuraih, A.
    Al Hossain, N.
    Babikir, E.
    Alkhorayef, M.
    Khandaker, Mayeen Uddin
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [37] Determination of radiation dose during computed tomography examinations in southern Saudi Arabian hospitals using size-specific dose estimates
    Saeed, Mohammed K.
    Asiri, Abdullah Ali M.
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 15 (02) : 147 - 158
  • [38] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [39] Radiation dose and image quality in spiral computed tomography:: multicentre evaluation at six institutions
    Scheck, RJ
    Coppenrath, EM
    Kellner, MW
    Lehmann, KJ
    Rock, C
    Rieger, J
    Rothmeier, L
    Schweden, F
    Bäuml, AA
    Hahn, K
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847): : 734 - 744
  • [40] Evaluation of Radiation Dose and Image Quality for TheVarian Cone Beam Computed Tomography System
    Cheng, H.
    Wu, V.
    Liu, E.
    Kwong, D.
    MEDICAL PHYSICS, 2011, 38 (06)